5 floors · 28 apartments · 17,510 sq ft · built 1920 · class C6 · owner of record: Fireside Tenants Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 45 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 45 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 61 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 289 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-28 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 30, 2024 | Boilers CLASS - 2 FOUND A H.B.SMTH 28A-7 STEAM BOILER WITH OPENING ON FLUE PIPE GOING INTO CHIMNEY/DRYER FLUE PIPE HAS TO BE FIRE RATED/AIR FAN PROVING SWITCH HAS TO BE CONNECTED/CORRECT ALL VIOLATING CONDITION/SUBMIT OF CERTIFI #39126121N | Sep 30, 2025 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #03068 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #03899 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #03792 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #04363 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 6, 2019 | Elevators ACC1 | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 6, 2016 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Jan 9, 2017 |
| Oct 6, 2016 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY | Jan 9, 2017 |
| Oct 6, 2016 | A | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Jan 9, 2017 |
| Oct 6, 2016 | A | SECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Jan 9, 2017 |
| Oct 6, 2016 | A | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY | Jan 9, 2017 |
| Oct 4, 2016 | B | Apt 302 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 302, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 8, 2016 |
| Oct 4, 2016 | B | Apt 302 · SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 302, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 8, 2016 |
| Oct 4, 2016 | B | Apt 302 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE IN THE ENTRANCE LOCATED AT APT 302, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 8, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MOLDING FLOOR THRU OUT 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING NORTHWEST ROOM 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL RECESS WINDOW NORTHWEST ROOM 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL BEHIND WASHBASIN BATHROOM 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASEBOARD MOLDING ALL ROOMS 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | C | SECTION 231 M/D LAW PROVIDE LEGAL SECOND MEANS OF EGRESS AND FILE APPLICATION FOR APPROVAL BEFORE DOING THE WORK 5 STY DUPLEX NORTHWEST APT WEST SECTION. | Dec 15, 2015 |
| Dec 9, 2015 | C | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WIRED GLASS AT SKYLIGHT 6 STY TO BULKHEAD ROOF. | Dec 15, 2015 |
| Dec 9, 2015 | B | SECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE BROKEN GLASS SHEETROCK DEBRIS 5 STY AND 6 STY PUBLIC HALL. | Jan 13, 2016 |
| Dec 9, 2015 | B | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 5 STY PUBLIC HALL AND 6 STY PUBLIC HALL. | Jan 13, 2016 |
| Dec 9, 2015 | C | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORY | Dec 15, 2015 |
| Dec 9, 2015 | B | Apt 504 · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT ENTRANCE LOCATED AT APT 504, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 201 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW LOWER SASH COUNTER BALANCE IN THE 1st ROOM FROM NORTH LOCATED AT APT 201, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 13, 2016 |
| Dec 9, 2015 | C | Apt 501 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL 5 STY FRONT APT 501 FRONT ROOM DUPLEX APT R147 ER1. , SECTION '' '' | Dec 15, 2015 |
| Dec 9, 2015 | C | Apt 501 · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SKYLIGHT AT ROOF 5 STY DUPLEX APT 501 TOP ROOM R148 ER1. , SECTION '' '' | Dec 15, 2015 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CONTROLE KNOB OVEN 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS SOUTHEAST ROOM 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MASONRY POINTING EAST BRICK WALL 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
| Dec 9, 2015 | B | Apt 403 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FLOOR SLATS CLOSET SOUTHEAST ROOM 4 STY SOUTH APT 403. , SECTION '' '' | Jan 13, 2016 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 16, 2026, 8:21 AM ET. BBL 1015400034.