6 floors · 19,944 sq ft · built 1920 · class N2 · owner of record: Manhattan Midtown Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-08-18 (Accepted). Agency page | Dec 31, 2026 in 44 days | 3 of 3 without an accepted 2026 report yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 9, 2026 | Elevators CLASS - 1 CLASS 1 AGG 2 RTS: FAILURE TO MAINTAIN ELEVATOR IN CODE-COMPLIANT OPERATING CONDITION. ELEVATOR CURRENTLY OUT OF SERVICE. SAME CONDITION PREVIOUSLY CITED UNDER AGG 1 ON 08/20/26. ACCORDING TO FACILITY STAFF, EL #39211150Z | Jan 14, 2027 PENDING | $6,250 |
| Aug 20, 2026 | Elevators CLASS - 1 CLASS 1 RTS - AGG 1: DEVICE FOUND OUT OF SERVICE, CREATING AN IMMEDIATELY UNSAFE CONDITION CONTRARY TO BC 3001.2 AND 1 RCNY 11-02. DOB RECORDS SHOW THE DEVICE WAS PREVIOUSLY CITED WITH AN RTS VIOLATION, ESTABLI #39201210M | Dec 10, 2026 PENDING | $3,125 |
| Aug 6, 2026 | Elevators CLASS - 1 CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION #39199476J | Oct 15, 2026 DEFAULT | $1,280 |
| Dec 11, 2025 | Elevators CLASS - 2 CLASS 2: IN-CAR EMERGENCY LIGHTING INOPERATIVE, REPAIR. #39170032J | Mar 19, 2026 IN VIOLATION | $625 |
| Nov 13, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, VIOLATING CONDITION REPAIRED NO CERTIFICATE OF CORRECTION ON FILE FOR #39166809H | Jan 22, 2026 IN VIOLATION | $1,250 |
| Mar 5, 2025 | Unknown CLASS - 2 I OBSERVED THE USE OF THE ROOFTOP EXHAUST FAN DISCONNECT AS A RACEWAY, THIS IS NOT PERMITTED AS THE REMOVAL OF THE DISCONNECT SWITCH FOR ANY PURPOSE, INTERRUPTS THE CIRCUIT(S) PASSING THRU. JUNCTION BOXES AND A #39140468N | May 15, 2025 IN VIOLATION | $0 |
| Sep 20, 2019 | Elevators CLASS - 2 92.M.7,59.BB.7,98.BB.7,99.BB.7=PROVIDE AUTI SPIN OUT FOR CABLE SHACKLES (59,BB,7) BRAKE MAINTENANCE TAG EXPIRED (98,BB,7) CAT 5 TAG EXPIRED (99,BB,7) CAT 1 TAG EPIRED #38271783R | Nov 21, 2019 DEFAULT | $0 |
| Aug 3, 2018 | Boilers CLASS - 2 B254.50A.50B.50C.50D.AS PER CLASS 2 (B254)28-301.1 .FAILURE TO MAINTAIN 50A.PIPING NOT PROPERLY SUPPORTED OVER BOILER.50B.HOT WATER PIPING NOT CAPPED.50C.SIGHT GLASS GUARD MISSING.50D.SIGHT GLASS DIRTY #32097651X | Nov 8, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED WATER MAIN BREAK UNDER SIDEWALK WHICH HAS LEAD TO A HOLE APPROX 10"X10" ON SIDEWALK SIDE OF WALL AT EXPOSURE #1. REPAIR OR REPLACE WATER SUPPLY LINE TO BUILDING. #23-03104 | DOB VIOLATION - ACTIVE |
| Apr 17, 2017 | ELEVATOR #9028/602129 | DOB VIOLATION - ACTIVE |
| Jun 28, 2004 | ELEVATOR #9444/104201 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 9, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 17, 2025 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Apr 29, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 2, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Nov 9, 2026 | ECB | Elevators: CLASS 1 AGG 2 RTS: FAILURE TO MAINTAIN ELEVATOR IN CODE-COMPLIANT OPERATING CONDITION. ELEVATOR CURRENTLY OUT OF SERVICE. SAME CONDITION PREVIOUSLY CITED UNDER AGG 1 ON 08/20/26. ACCORDING TO FACILITY STAFF, EL | Open |
| Sep 25, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 9, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 20, 2026 | ECB | Elevators: CLASS 1 RTS - AGG 1: DEVICE FOUND OUT OF SERVICE, CREATING AN IMMEDIATELY UNSAFE CONDITION CONTRARY TO BC 3001.2 AND 1 RCNY 11-02. DOB RECORDS SHOW THE DEVICE WAS PREVIOUSLY CITED WITH AN RTS VIOLATION, ESTABLI | Open |
| Aug 6, 2026 | ECB | Elevators: CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)