Bronx · Block 3030 · Lot 141 · 10457

2248 Webster Avenue

5 floors · 27 apartments · 16,120 sq ft · built 1913 · class C1 · owner of record: 2248 Webster Avenue Housing Development Fund Compa

7open violations
$6,190ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2019-12-10 (Accepted). Agency page

Dec 31, 2026
in 66 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual

Open violations

ECB / OATH (3) · $6,190 owed
IssuedViolationHearingBalance
Jul 30, 2026Construction CLASS - 1
ATOI OBSERVED ON 4TH AND 5TH FLOOR OBSTRUCTED SPRINKLER HEADS CONTRARY TO FGC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLERS BE POSITIONED TO AVOID OBSTRUCTIONS TH
#39198366Y
Oct 16, 2026
DEFAULT
$2,530
Jul 30, 2026Unknown CLASS - 1
ELECTRICAL CLOSET NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY. OBSERVED IN THE BASEMENT THE ELECTRICAL EQUIPMENT / PANELS ARE SHARING THE SAME ROOM AS HOT WATER TANKS AND BOILER. ELECTRICAL DISTRIBU
#39198369J
Oct 16, 2026
DEFAULT
$1,230
Jul 30, 2026Unknown CLASS - 2
FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. OBSERVED THRU OUT THE BUILDING ON ALL FLOORS THE SLEEPING QUARTERS ARE NOT RECEPTACLES AND LIGHTING ARE NOT ARC FAULT PROTEC
#39198370R
Oct 16, 2026
DEFAULT
$2,430
DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Sep 2, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 2, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (2) · C 2 · B 0 · A 0
IssuedClassViolationCorrect by
Nov 19, 2020C§ 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.Nov 23, 2020
Jul 14, 2020C§ 27-2056.4(H) AND 27-2056.17 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.Jul 18, 2020

Issued in the last 120 days

DateSourceWhatNow
Sep 2, 2026DOB SafetyAEUHAZ: Open
Sep 2, 2026DOB SafetyAEUHAZ: Open
Jul 30, 2026ECBConstruction: ATOI OBSERVED ON 4TH AND 5TH FLOOR OBSTRUCTED SPRINKLER HEADS CONTRARY TO FGC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLERS BE POSITIONED TO AVOID OBSTRUCTIONS THOpen
Jul 30, 2026ECBUnknown: ELECTRICAL CLOSET NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY. OBSERVED IN THE BASEMENT THE ELECTRICAL EQUIPMENT / PANELS ARE SHARING THE SAME ROOM AS HOT WATER TANKS AND BOILER. ELECTRICAL DISTRIBUOpen
Jul 30, 2026ECBUnknown: FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. OBSERVED THRU OUT THE BUILDING ON ALL FLOORS THE SLEEPING QUARTERS ARE NOT RECEPTACLES AND LIGHTING ARE NOT ARC FAULT PROTECOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 4:49 AM ET. BBL 2030300141.