14 floors · 142,801 sq ft · built 1925 · class O6 · owner of record: Mb Hamptons, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $22,750 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 99 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 142,801 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 779). Agency page | Dec 31, 2029 in 1143 days | Next due 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-14 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 17, 2024 | Construction CLASS - 2 A. C. 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MOR #37028757R | Feb 7, 2025 IN VIOLATION | $0 |
| Feb 28, 2023 | Construction CLASS - 2 27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE FINAL SPRINKLER REPORT PREPARED BY REGISTERED DESIGNPROFESSIONAL IN OFFICE BLDG 100 FT OR MORE IN HEIGHT IN EXISTENCE ON #37025334L | Apr 25, 2024 IN VIOLATION | $0 |
| Mar 30, 2021 | Construction CLASS - 2 SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BLDG 100 FEET OR MORE IN HEIG #37020949P | Oct 14, 2021 IN VIOLATION | $0 |
| Mar 30, 2020 | Construction CLASS - 2 SEC. 27-929.1 AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG #37018879X | Jul 2, 2020 DEFAULT | $0 |
| Dec 30, 2019 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS. NOTED, AT THE TIME OF INSPECTION OBSERVED THE 1ST FLOOR COMMERCIAL STORE OCCUPIED AS A GYM STORE CONTRARY TO C #39015030X | Feb 13, 2020 DEFAULT | $0 |
| Dec 30, 2019 | Zoning CLASS - 2 FAILURE TO COMPLY THE REQUIREMENTS OF ZONING RESOLUTION OR REGULATION TO OBTAIN BOARD OF STANDARD APPEALS FOR PHYSICAL CULTURE ESTABLISHMENT. NOTED, AT THE TIME OF INSPECTION OBSERVED AT THE TIME OF INSPECTION #39015031H | Feb 13, 2020 DEFAULT | $0 |
| Nov 21, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES.EXPOSURE 1,NORTH ELEVATION:13 STORY AT SET BACKS-CRACKS AT BRICKS,ERODED MORTAR JOINTS,FAILED REPAIR,7TH STY ERODED MORTAR JOINTS AT WEST CO #35444845R | May 21, 2020 IN VIOLATION | $0 |
| Nov 15, 2019 | Construction CLASS - 2 27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BUILDIN #37016136X | Feb 13, 2020 DEFAULT | $0 |
| Jul 27, 2011 | Unknown CLASS - 2 FAILURE TO TIMELY FILE BICYCLE ACCESS PLAN OR AMENDMENT W/ DOT AS PRESCRIBED IN 34 RCNY 2-18.BLDG DID NOT FILE PLAN OR EXCEPTION REQUEST IN RESPONDE TO TENANT REQUEST FOR BICYCLE ACCESS.REM:FILE BICYCLE ACCESS #34834187L | Sep 12, 2011 IN VIOLATION | $0 |
| Mar 8, 2007 | Local Law Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG. NORTH ELEVATION SHOWS CRACKS IN PARAPET FACADE; BULGING & SHIPPING IN FACADE LINTELS, DETERIORATING & SPALLING IN LINTELS; STEP CRACKS & BULGING IN FACADE SET BACK. #34418317H | Aug 9, 2007 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 17, 2021 | ELEVATOR #9027/703416 | DOB VIOLATION - ACTIVE |
| Sep 3, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF00902 | DOB VIOLATION - ACTIVE |
| May 9, 2016 | ELEVATOR #9027/572934 | DOB VIOLATION - ACTIVE |
| Jun 30, 2015 | ELEVATOR #9028/543366 | DOB VIOLATION - ACTIVE |
| Jul 25, 2013 | ELEVATOR #9028/479078 | DOB VIOLATION - ACTIVE |
| Aug 24, 2005 | ELEVATOR #94441138454 | DOB VIOLATION - ACTIVE |
| Mar 23, 1999 | CONSTRUCTION #STC02VW | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Mar 23, 1999 | PLUMBING #STC01VW | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 2:53 PM ET. BBL 1007790057.