5 floors · 46,255 sq ft · built 2002 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 43 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 46,255 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-27 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 10, 2026 | Construction CLASS - 2 REISSUED ECB #35720009J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT 1ST FLOOR CORRIDOR OF GRAND AND E. 163 STREET HANDICAP LIFT NOT WORKING. REMEDY: REPAIR AND/OR REPLACE. #35732201H | May 15, 2026 POP/IN-VIO | $0 |
| Apr 10, 2026 | Construction CLASS - 2 REISSUED ECB #35720008H. EXIT DOORS NOT SELF-CLOSING. NOTED: SMOKE DOOR AT STAIR B 5TH FLOOR; 3RD FLOOR STAIR B, 2ND FLOOR STAIR B AND STAIRA NOT SELF-CLOSING. REMEDY: REPAIR AND/OR REPLACE. #35732200X | May 15, 2026 POP/IN-VIO | $0 |
| May 20, 2025 | Construction CLASS - 2 REISSUE#35684633H DATE OF ISSUE:07.18.2024 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 4TH FLOOR CLASSROOM NO#423,451 CEILING IS IN STATE OF DISREPAIR W #35720007X | Aug 15, 2025 POP/IN-VIO | $0 |
| May 20, 2025 | Construction CLASS - 2 EXIT DOOR NOT SELF CLOSING PROPERLY AT THE TIME OF INSPECTION.AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 5TH FL.STAIRWAY B 2 EXIT DOOR,4TH FL STAIRWAY A ONE EXIT DOOR,3RD FL.STAIRWAY B 2 EXIT DOORS,2ND FL. #35720008H | Aug 15, 2025 POP/IN-VIO | $0 |
| May 20, 2025 | Construction CLASS - 2 REISSUE#35684634J DATE OF ISSUE:07.18.2024 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION OBSERVED AND NOTED AT REAR STAIR A 1ST FLOOR CORNER OF GRANT AVE & EAST 163 RD ST HAS A #35720009J | Aug 15, 2025 POP/IN-VIO | $0 |
| Aug 26, 2024 | Elevators CLASS - 2 IN-CAR COMMUNICATION AND EMERGENCY LIGHTING ARE INOPERATIVE. CATEGORY 1 TEST TAG EXPIRED. #39123015X | Aug 30, 2024 POP/IN-VIO | $0 |
| Aug 26, 2024 | Elevators CLASS - 2 : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE AND CALL THE DOB ELEVATOR DIVISION AT (212) 393-2144 FOR A RE-INSPE #39123014Y | Aug 30, 2024 POP/IN-VIO | $0 |
| Jul 18, 2024 | Construction CLASS - 2 REISSUE #35672102K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF MY INSPECTION, I OBSERVED AT THE 4TH DOOR AT CLASS ROOM #423 AND #61. CEILING IN STATE OF DISREPAIR WITH WATER PENETRATIONS #35684633H | Sep 27, 2024 POP/IN-VIO | $0 |
| Jul 18, 2024 | Construction CLASS - 2 REISSUE #35672101Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, I OBSERVED AT THE REAR AT STAIR A, AT 1ST FLOOR LEVEL CORNER OF GRANT AVENUE AND EAST 163RD STREET HAS A HANDICA #35684634J | Sep 27, 2024 POP/IN-VIO | $0 |
| Mar 16, 2023 | Construction CLASS - 2 REISSUE#35654904N-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTE:OBSERVED REAR STAIR A-1ST FLR CORNER OF GRANT AVE & E.163RD ST HAS A HANDICAP LIFT THAT IS NOT OPERATIONAL AT THIS TIME.REM:REPAIR AN #35672101Z | Jun 30, 2023 POP/IN-VIO | $0 |
| Mar 16, 2023 | Construction CLASS - 2 REISSUE#35654903L FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTE:OBSERVED AT 4TH FLR CLASSROOM#423 & #451,CEILING IS IN STATE OFDISREPAIR WITH WATER PENETRATIONS COMING FROM THE ROOF.REM:REPAIR AND/ #35672102K | Jun 30, 2023 POP/IN-VIO | $0 |
| May 25, 2022 | Construction CLASS - 2 REISSUE#35548228H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED AT 4TH FLR CLASSROOM#423 & #451,CEILING IN STATE OF DISREPAIR WITH SIGNS OF WATER PENETRATIONS COMING FROM ROOF.REM:REPAIR #35654903L | Sep 2, 2022 POP/IN-VIO | $0 |
| May 25, 2022 | Construction CLASS - 2 REISSUE#35527037M FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED AT EXIT#/CORNER OF GRANT AVE & E 163RD ST,HANDICAP LIFT IS NOT OPERATIONAL DURING INSPECTION.REM:REPAIR AND/OR REPLACE THE #35654904N | Sep 2, 2022 POP/IN-VIO | $0 |
| Feb 9, 2021 | Construction CLASS - 2 REISSUE#35473490J FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:NOTED:CEILING LEAKS@CLASSRM423,451 DUE TO WATER LEAKS.REPAIR &/OR REPLACE. #35548228H | May 21, 2021 POP/IN-VIO | $0 |
| Feb 9, 2021 | Construction CLASS - 2 REISSUE#35094422H FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTED:GRANTAVE,EAST 163 HANDICAP LIFT NOT WORKING.MAINTAIN AS PER CODE.COMPLY W/COMMISSIONER'S ORDER. #35527037M | May 21, 2021 POP/IN-VIO | $0 |
| Sep 1, 2020 | Boilers CLASS - 2 NO SHUT OFF VALVE ON FUEL OIL SUPPLY PIPE-CORROSION ON LWC AND WATER COLUMN PIPING-HLW HOT WATER MAKER FLUE PIPING HAS A SECOND DRAFT REGULATOR-SUMP PUMP NOT DISCHARGING AUTOMATICALLY, STORM WATER FLOODING BOIL #39027864K | Sep 16, 2020 POP/IN-VIO | $0 |
| Apr 27, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED AT CLASSROOM 423,451,CEILING LEAK DUE TO DEFECTIV EROOF MAKE NECESSARY REPAIRS #35473490J | Aug 21, 2020 POP/IN-VIO | $0 |
| Mar 14, 2019 | Construction CLASS - 2 REISSUE VIO#35291041R FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED HANDICAP LIFT AT GRANT AVE IS NOT OPERATIONAL. REMEDY: REPAIR OR REPLACE #35386460N | Jun 7, 2019 POP/IN-VIO | $0 |
| Jan 31, 2018 | Construction CLASS - 2 RE-ISSUE VIOLATION# 35094422H. FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: HANDICAP LIFT @ GRANT AVE IS NOT OPERATIONAL. REM: REPAIR &/OR REPLACE. #35291041R | Apr 20, 2018 POP/IN-VIO | $0 |
| Mar 13, 2017 | Construction CLASS - 2 REISSUE VIO#35094422H FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: HANDICAP LIFT GRANT AVE IS NOT OPERATIONAL. REMEDY: REPAIR &/OR REPLACE. #35229244J | May 5, 2017 POP/IN-VIO | $0 |
| Sep 8, 2015 | Construction CLASS - 2 RE-ISSUE #35094423J.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. HANDICAP LIFT NOT OPERATIONAL. REMEDY:COMPLY WITH NOTICE OF VIOLATION. #35127839L | Jan 8, 2016 POP/IN-VIO | $0 |
| May 6, 2014 | Construction CLASS - 2 EXIT AT GRANT AVE AND EAST 163 ST LIFT HANDICAP LIFT NOT OPERATIONAL REMEDY: MAINTAIN BUILDING AS PER CODE #35094422H | Oct 31, 2014 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07904 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07903 | DOB VIOLATION - ACTIVE |
| Sep 7, 2021 | ELEVATOR #9028/707602 | DOB VIOLATION - ACTIVE |
| Aug 13, 2020 | ELEVATOR #9028/682490 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #07319 | DOB VIOLATION - ACTIVE |
| Jul 9, 2019 | ELEVATOR #9028/655329 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)