Brooklyn · Block 426 · Lot 36 · 11217

224 3 Avenue

11 floors · 60 apartments · 59,313 sq ft · built 2025 · class D7 · owner of record: Sackett Apartments Llc

0open violations
$23,650ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 426). Agency page

Dec 31, 2026
in 66 days
Due this year
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 118 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 59,313 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found

Open violations

ECB / OATH (8) · $23,650 owed
IssuedViolationHearingBalance
Jun 7, 2026Construction CLASS - 2
BC 3301.1.3 AT TIME OF INSPECTION, A YODOCK BARRIER SYSTEM WAS OBSERVED WITH MISSING INTERLOCKING COUPLERS THROUGHOUT AND BARRIERS NOT FILLED WITH WATER OR SAND AS REQUIRED. THIS CONDITION CREATES A SAFETY HAZ
#39555142H
Oct 14, 2026
IN VIOLATION
$1,250
Feb 22, 2026Unknown CLASS - 2
BC 3303.3. ATOI OF A 11 STORY NB AT ROOF, BUILDING APPROXIMATELY 6433 SQ. FT. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WATCHPERSON A
#39550756J
Nov 6, 2026
$2,500
Dec 21, 2025Unknown CLASS - 1
BC 3301.1.1 UNSAFE CONDITIONS - OBSERVED MULTIPLE LOCATIONS WITH TARPS CONNECTED TO TEMPORARY FORMWORK AND EQUIPMENT CREATING THE SAIL EFFECT. STOP ALL USE OF TARPS ON TEMPORARY EQUIPMENT TO PREVENT A POSSIBLE
#39548385R
Dec 7, 2026
$5,000
Dec 21, 2025Construction CLASS - 1
UPON INSPECTION ACTIVE CONSTRUCTION ACTIVITIES WERE OBSERVED, WORKERS NOISE & CONVERSATION HEARD ON SITE,AFTER REVIEW OF BIS & DOB SYSTEM RECORDS, THE DEPARTMENT RECORDS INDICATE NO AVH PERMIT WAS OBTAIN / ON F
#39548387K
Dec 7, 2026
$2,500
Dec 21, 2025Construction CLASS - 2
UPON INSPECTION OBSERVED, SIDEWALK SHED WITH STORAGE OF MATERIAL ON TOP OF THE SHED DECK, WHICH IS CONTRARY TO THE DESIGN DRAWING, REVIEW OF THE DRAWINGS INDICATES NO STORAGE ON SHED DECK. STOP ALL USE OF SIDEW
#39548383N
Dec 7, 2026
$2,400
Dec 21, 2025Construction CLASS - 1
UPON INSPECTION PROPOSED 11 STORY MAJOR NB OBSERVED AT 7 STORY, APPROX. 75 FT HEIGH, AFTER REVIEW OF BIS & DOB SYSTEM RECORDS, THE DEPARTMENT RECORDS INDICATE THAT ONLY STRUCTURAL PERMIT B00727869-S3-ST WAS ISS
#39548386Z
Dec 7, 2026
$2,500
Dec 21, 2025Construction CLASS - 2
ACTIVE CONSTRUCTION ACTIVITIES WERE OBSERVED, WORKERS NOISE & CONVERSATION HEARD ON SITE. UPON BANGING & CALLING OUT WORKERS NOTICE AND BECAME QUITE CONTINUING CALLING & BANGING FOR APPROX.. 30-45 MINUTES WORKE
#39548384P
Dec 7, 2026
$2,500
Dec 21, 2025Plumbing CLASS - 1
OBSERVED A MAJOR BUILDING CURRENTLY ON THE 11TH FLOOR, AND OBSERVED A STANDPIPE IN THE STREET. UPON REVIEW, THE DEPARTMENT RECORDS ALERTED ME THAT NO HYDROSTATIC TEST WAS PERFORMED FOR THE FIRST 75 FEET. FAIL T
#39548390L
Dec 7, 2026
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 9:08 PM ET. BBL 3004260036.