Bronx · Block 3537 · Lot 1 · 10473

2225 Lacombe Avenue

12 floors · 583 apartments · 576,011 sq ft · built 1959 · class D1 · owner of record: Nyc Housing Authority

14open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 56 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 56 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 72 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 576,011 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 177 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 177 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3537). Agency page

Dec 31, 2027
in 421 days
Next due 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 473 days
No Cycle 10 report on record yet

Open violations

ECB / OATH (0)

None open.

DOB (10)
IssuedViolationStatus
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#01470
DOB VIOLATION - ACTIVE
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#00578
DOB VIOLATION - ACTIVE
Jul 1, 1992LL10/80-LOCAL LAW 10/80 - FACADE

#01377NRF
DOB VIOLATION - ACTIVE
Apr 7, 1992LOCAL LAW 10/81 - ELEVATOR
2
#03259
DOB VIOLATION - ACTIVE
Jul 31, 1990ELEVATOR
(17)GLASS OUT 1ST FLOOR
#1450C5
DOB VIOLATION - ACTIVE
Jul 31, 1990ELEVATOR
(17)1ST,9TH GLASS OUT.(73)RESTORE ELEVATOR TO SERVICE SO PROPER INSPECTION CAN BE DONE BY THIS DEPARTMENT
#1450C3
DOB VIOLATION - ACTIVE
Jul 31, 1990ELEVATOR
(17)GLASS OUT 1ST FL,6TH,& 12TH FLOORS
#1450C6
DOB VIOLATION - ACTIVE
Jul 31, 1990ELEVATOR
(17)GLASS OUT 1ST,6TH,8TH,&10TH FLOORS.(37)CAR STOP AT 2ND FLOOR RETURN UP
#1450C4
DOB VIOLATION - ACTIVE
Jul 31, 1990ELEVATOR
(17)GLASS OUT 2ND,4TH,6TH,8TH,10TH,11TH,12TH,13TH,14TH,15TH,18TH, 19TH FLOORS.(18)8TH FLOOR
#1450C1
DOB VIOLATION - ACTIVE
Jul 31, 1990ELEVATOR
(17)GLASS OUT MAIN FLOOR,2ND,4TH,6TH,8TH,9TH,10TH,11TH,12TH,13TH, 14TH,19TH.(73)RESTORED ELEVATOR SO PROPER INSPECTION CAN BE MADE BY THIS DEPARTMENT
#1450C2
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
HPD (2) · C 0 · B 2 · A 0
IssuedClassViolationCorrect by
May 8, 2006BApt 7I · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SHOWER BODY IN THE BATHROOM LOCATED AT APT 7I, 7th STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2006
May 8, 2006BApt 7I · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FAUCET ASSEMBLY AT SHOWER BODY IN THE BATHROOM LOCATED AT APT 7I, 7th STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2006

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 10:03 PM ET. BBL 2035370001.

Look up another building