9 floors · 29 apartments · 30,248 sq ft · built 2009 · class RR · owner of record: 2217 Caton Avenue Condominum
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 30,248 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 181 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 181 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 425 days | Next cycle year 2027 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $32,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 843 days | Filing window not open yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 15, 2026 | Elevators CLASS - 2 1) EXPIRED BRAKE MAINTENANCE TAG. 2) EXPIRED CAT5 TAG. 3) SECURE BOLTS ON SHACKLES THAT IS ON THE COUNTER WEIGHT FRAME (LOOSENED). 4) EQUALIZE CABLES. 5) EXCESSIVE METAL SHAVINGS SEEN AROUND HOIST MACHINE. #39188748K | Jul 22, 2026 DEFAULT | $1,562 |
| Aug 6, 2021 | Elevators CLASS - 2 REPAIR 3RD FLOOR DOOR LOCK. CHANGE CAR DOOR HANGER ROLLERS. CHANGE CAR ROLLER GUIDE. #39045654L | Jan 24, 2024 DEFAULT | $1,562 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Sep 23, 2026 | Parking Structures FTF-PS-INITL Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 28, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCK AT CELLAR AT BOILER ROOM | Oct 4, 2026 |
| Sep 24, 2026 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REFERIGERATOR WITH DOORS ATTACHED AT PUBLIC HALL STAIRS, 6th STORY, SECTION ''EAST'' | Sep 30, 2026 |
| Sep 9, 2026 | B | Apt 6B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 14, 2026 |
| Sep 9, 2026 | B | Apt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CIELING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 14, 2026 |
| Sep 9, 2026 | C | Apt 6B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 5, 2026 |
| Sep 4, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Dec 8, 2026 |
| Sep 3, 2026 | B | Apt 4D · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 8, 2026 |
| Sep 3, 2026 | B | Apt 4D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 8, 2026 |
| Sep 3, 2026 | B | Apt 4D · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 8, 2026 |
| Sep 3, 2026 | C | Apt 4D · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 17, 2026 |
| Jan 15, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT BUILDING ENTRANCE DOOR | Jan 21, 2026 |
| Jan 15, 2026 | B | § 27-2005 ADM CODE PROVIDE AN ACCEPTABLE HEAVY DUTY LOCK AND LACH SET INSTALLED AT BUILDING ENTRANCE DOOR | Feb 19, 2026 |
| Oct 31, 2025 | B | Apt 6D · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 5, 2025 |
| Feb 28, 2024 | B | Apt 9C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX SQUARE FEET AT EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 9C, 9th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16342406 ISSUED 27-OCT-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE C | Apr 3, 2024 |
| Aug 16, 2021 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER., 1st STORY | Nov 19, 2021 |
| May 25, 2021 | B | Apt 7B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1SQ.FT. AT THE CLOSET CEILIN G IN THE 2nd ROOM FROM EAST LOCATED AT APT 7B, 7th STORY, APARTMENT AT EAST ORIGINAL VIOLATION 14002763 ISSUED 24-JAN-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2 | Jun 29, 2021 |
| May 25, 2021 | B | Apt 7B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 1SQ.FT. AT THE LOWER SECTION OF THE EAST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 7B, 7th STORY, APARTMENT AT EAST ORIGINAL VIOLATION 14002765 ISSUED 24-JAN-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTR | Jun 29, 2021 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 28, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCK AT CELLAR AT BOILER ROOM | Open |
| Sep 24, 2026 | HPD C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REFERIGERATOR WITH DOORS ATTACHED AT PUBLIC HALL STAIRS, 6th STORY, SECTION ''EAST'' | Open |
| Sep 23, 2026 | DOB Safety | Parking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Open |
| Sep 23, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 9A, 9th STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
| Sep 9, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 9, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CIELING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 9, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 9, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT HOPPER DOOR AT SOUTH WALL , 6th STORY | Closed |
| Sep 4, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Open |
| Sep 3, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 3, 2026 | HPD B | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 3, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 3, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)