6 floors · 52 apartments · 63,960 sq ft · built 1934 · class D1 · owner of record: Ditmas Park 2212 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 63,960 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 429 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5208). Agency page | Dec 31, 2028 in 795 days | Next due 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-28 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 14, 2020 | Elevators CLASS - 1 DOOR ZONE LOCK BYPASSED/MISSING PARTS. THIS IS A SAFETY DEVICE ON THE ELEVATOR TO ENSURE PASSENGER SAFETY. REPAIR DEVICE AND RE-INSPECTION REQUIRED. #39030375R | Feb 17, 2021 IN VIOLATION | $1,250 |
| Issued | Violation | Status |
|---|---|---|
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #05655 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #06500 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 26, 2018 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 26, 2026 | B | Apt 4B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Oct 26, 2026 | B | Apt 4B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING INSIDE CLOSET AND AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Oct 26, 2026 | B | Apt 4B · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Oct 26, 2026 | B | Apt 4B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Oct 26, 2026 | C | Apt 4B · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET IN THE ENTRANCE LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 26, 2026 | B | Apt 4B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Oct 26, 2026 | B | Apt 4B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Oct 26, 2026 | C | Apt 4B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 21, 2026 |
| Oct 26, 2026 | B | Apt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT UPPER WINDOW SASH AT (1ST, 2ND) WINDOW FROM NORTH AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Oct 26, 2026 | B | Apt 4B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING INSIDE CLOSET AND EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Sep 8, 2026 | A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY CAPS AT PUBLIC HALL, 1st STORY | Dec 12, 2026 |
| Sep 8, 2026 | C | Apt 4G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 4, 2026 |
| Sep 8, 2026 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS, AT PUBLIC HALL, 1st STORY | Oct 13, 2026 |
| Sep 8, 2026 | C | Apt 4G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 4, 2026 |
| Sep 8, 2026 | B | Apt 4G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN SEAL AT LOWER REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jul 23, 2026 | A | Apt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 26, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE FOYER LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT WEST WALL IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jul 23, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER CHUTE AT COMPACTOR CLOSET, 3rd STORY | Aug 6, 2026 |
| Jul 23, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER CHUTE AT COMPACTOR CLOSET, 1st STORY | Aug 6, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT STANDING SHOWER IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jul 23, 2026 | C | Apt 6E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 18, 2026 |
| Jul 23, 2026 | A | Apt 6E · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 26, 2026 |
| Jul 23, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER CHUTE AT COMPACTOR CLOSET, 4th STORY | Aug 6, 2026 |
| Jul 23, 2026 | C | Apt 6E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 6, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jul 23, 2026 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 27, 2026 |
| Jun 30, 2026 | C | Apt 5J · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Jul 24, 2026 |
| Jun 29, 2026 | A | Apt 5J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 2, 2026 |
| Jun 29, 2026 | A | Apt 5J · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM WEST AT NORTH WALL, 2nd WINDOW FRAME FROM WEST AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 2, 2026 |
| Jun 29, 2026 | A | Apt 5J · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 2, 2026 |
| Jun 29, 2026 | C | Apt 5J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5J, 5th | Jul 23, 2026 |
| Jun 29, 2026 | C | Apt 5J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE AND EITHER TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 OR TESTED POSITIVE FOR LEAD CONTENT ON A METAL OR CERAMIC SUBSTRATE AS SET FORTH IN (28 RCNY §11-07(b)) USING WORK PRACTICES S | Jul 23, 2026 |
| Jun 29, 2026 | C | Apt 5J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2 | Jul 23, 2026 |
| Jun 29, 2026 | C | Apt 5J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT A | Jul 23, 2026 |
| Jun 29, 2026 | A | Apt 5J · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE FOYER , THE 1st ROOM FROM NORTH AT EAST, THE PRIVATE HALLWAY LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 2, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | A | Apt 5J · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 2, 2026 |
| Jun 29, 2026 | C | Apt 5J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 25, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ESCUTCHEON PLATE AT RISER AT NORTH WALL AT CEILING IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD BASEBOARD AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | A | Apt 5J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT 2nd WINDOW FRAME FROM WEST AT NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 2, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL, SOUTH WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 5J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 29, 2026 | A | Apt 5J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 2, 2026 |
| Jun 22, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Jul 18, 2026 |
| Dec 18, 2025 | A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVERS FOR ELECTRICAL OUTLETS AT NORTH WALL AT PUBLIC HALL, 1st STORY | Mar 23, 2026 |
| Sep 19, 2025 | C | Apt 6H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 15, 2025 |
| Sep 19, 2025 | C | Apt 6H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 15, 2025 |
| Sep 4, 2025 | B | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Oct 9, 2025 |
| Sep 4, 2025 | B | Apt 4A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Oct 9, 2025 |
| Sep 4, 2025 | B | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Oct 9, 2025 |
Showing 60 of 135. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 26, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING INSIDE CLOSET AND AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD B | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET IN THE ENTRANCE LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT UPPER WINDOW SASH AT (1ST, 2ND) WINDOW FROM NORTH AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING INSIDE CLOSET AND EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Sep 8, 2026 | HPD A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY CAPS AT PUBLIC HALL, 1st STORY | Open |
| Sep 8, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS, AT PUBLIC HALL, 1st STORY | Open |
| Sep 8, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN SEAL AT LOWER REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 23, 2026 | HPD B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSISTING OF A PANIC BAR INSTALLED AT ROOF DOOR THAT DOES NOT ALLOW RE-ENTRY FROM ROOF TO PUBLIC HALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY | Closed |
| Jul 23, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 23, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 23, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE FOYER LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 23, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT DOOR AT COMPACTOR CLOSET, 5th STORY | Closed |
| Jul 23, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ROOF DOOR AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY | Closed |
| Jul 23, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT WEST WALL IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 23, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT DOOR AT COMPACTOR CLOSET, 2nd STORY | Closed |
| Jul 23, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT DOOR AT COMPACTOR CLOSET, 3rd STORY | Closed |
| Jul 23, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND IT'S ASSEMBLY AT DOOR AT COMPACTOR CLOSET, 5th STORY | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)