1 floors · 2,748 sq ft · built 1952 · class K1 · owner of record: 221 Linden Blvd Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-23 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 27, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: OBSERVED AT FRONT OF BLDG,THE ENTIRE PARAPET WALL IS LEANING OUTWARD. REMEDY: MAINTAIN EXTERIOR BLDG WALL. #35636216K | Sep 29, 2022 DEFAULT | $12,500 |
| Nov 10, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTED:OBSERVED AT EXP #1(FRONT OF BUILDING)ENTIRE PARAPET WALL SLIGHTLY LEANING TO SIDEWALK/GROUND.REMEDY:MAINTAIN EXTERIOR BUILDING WALL. #35632084J | Jul 19, 2022 DEFAULT | $12,500 |
| Sep 20, 2021 | Construction CLASS - 1 AT FRONT OF BUILDING PARAPET WALL IS OUT OF PLUMB AND LEANS TOWARD STREET., ALSO NOTED WATERPROOFING MEMBRANE IS OPEN AT ROOF SIDE OF PARAPET., MAINTAIN EXTERIOR BUILDING WALL #39047786M | Nov 9, 2021 DEFAULT | $6,250 |
| May 16, 2014 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BLDG DEPT.RECORDS.NOTED:COQ #65217 INDICATES,CELLAR(STORAGE)1ST FL(RETAIL STORES).@ TIME OF INSP.1ST FL REAR HAS BEEN CONVERTED INTO SLEEPIN #35076251N | Dec 2, 2014 IN VIOLATION | $0 |
| Oct 24, 2006 | Construction Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY THE COFO.NOTED:C/O #65217 INDICATES 1)CELLAR-STORAGE;2)OSP-PARKING@REAR;3)001 FLR-(1)RETAIL STORE.@ TIME OF INSPEC.001 FLR IS OCCUPIED AS(2)STORES(SUB-DIVISION),AS INDICATE #34541202L | Dec 12, 2006 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 20, 2021 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT ROOF LEVEL PARAPET WALL LEANING OUTWARD AND WATERPROOFING MEMBRANE PULLING APART ON ROOF SIDE OF PARAPET. #21-01123 | DOB VIOLATION - ACTIVE |
| Sep 18, 2017 | CONSTRUCTION FAILURE TO COMPLY WITH STOP WORK ORDER ORDER ISSUED ON 8/9/2010 #C1301KC | DOB VIOLATION - ACTIVE |
| Aug 9, 2010 | CONSTRUCTION #1307ZC | DOB VIOLATION - ACTIVE |
| Jan 6, 2006 | LOCAL LAW 62/91 - BOILERS #21077 | DOB VIOLATION - ACTIVE |
| Jun 25, 1999 | IMMEDIATE EMERGENCY #218/99 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 6, 2006 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 9:14 PM ET. BBL 4113220001.