Queens · Block 11155 · Lot 35 · 11429

220-20 Hempstead Avenue

2 floors · 2 apartments · 2,356 sq ft · built 1925 · class S2 · owner of record: Esa, Eman Ali

24open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
1154dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 302 days
Required only if the owner doesn't live there
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1154 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-09 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (9)
IssuedViolationStatus
Dec 13, 2011LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
#20939
DOB VIOLATION - ACTIVE
Dec 31, 2009LOW PRESSURE BOILER

#24043
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#21646
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#22349
DOB VIOLATION - ACTIVE
May 4, 1998LOCAL LAW 62/91 - BOILERS

#30080
DOB VIOLATION - ACTIVE
Sep 16, 1997LOCAL LAW 62/91 - BOILERS

#272348
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#39171
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#40897
DOB VIOLATION - ACTIVE
Jun 28, 1993LOCAL LAW 62/91 - BOILERS

#09864
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Dec 13, 2011Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Active
Dec 31, 2009Boiler LBLVIO
Active
Jan 3, 2008Boiler LL6291
Active
Jan 31, 2005Boiler LL6291
Active
May 4, 1998Boiler LL6291
Active
Sep 16, 1997Boiler LL6291
Active
Feb 10, 1997Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
Jun 28, 1993Boiler LL6291
Active
HPD (6) · C 1 · B 5 · A 0
IssuedClassViolationCorrect by
Aug 6, 2009BSECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE handrails at 1st and 2nd story AT PUBLIC HALLSep 10, 2009
Aug 6, 2009BApt 2 · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE lower sash glass pane IN THE LIVING ROOM LOCATED AT APT 2, 2nd STORYSep 10, 2009
Aug 6, 2009BApt 2 · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN roaches IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORYSep 10, 2009
Aug 6, 2009CApt 1FL · SECTION 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT KITCHEN. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORYAug 12, 2009
Aug 6, 2009BApt 2F · SECTION 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES range IN THE KITCHEN LOCATED AT APT 2F, 2nd STORYSep 10, 2009
Aug 6, 2009BSECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE THROUGHOUT 2ND STORY. REAR APARTMENT # 2R.Sep 10, 2009

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 12:59 AM ET. BBL 4111550035.