Bronx · Block 4323 · Lot 35 · 10462

2196 Matthews Avenue

6 floors · 42 apartments · 34,518 sq ft · built 1940 · class D1 · owner of record: 2196 Realty Corp.

6open violations
$6,250ECB/OATH penalties owed
2HPD class C (immediately hazardous)
63dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 63 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 79 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 34,518 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 184 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 184 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 307 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 428 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-02 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (2) · $6,250 owed
IssuedViolationHearingBalance
Apr 8, 2025Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #919533. REMEDY: SUBMIT ACCEPTABLE REQU
#37035148R
Aug 1, 2025
IN VIOLATION
$0
Dec 12, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #2 NORTH(1) CRACKED/SPALLING BRICK MULTI LOC. AT SPANDREKS. (2)CRACKED/BULGING BRICK ABOVE TOP FL WINDOW C
#35689244R
Oct 27, 2025
DEFAULT
$6,250
DOB (1)
IssuedViolationStatus
Dec 12, 2024CONSTRUCTION
EWO DUE TO CRACKED/BULGING BRICK EXP2 N/W FACING WALL TOP FL CORNER & SPANDREDS BTW 5TH/6TH FL.CRACKED BRICK MORTAR JOINTS MULTI LOCAT @SPA -NDREDS OF EXP2 N.CONDITIONS POSE AN HZARD TO PUBLIC.REMDY: IMMEDLY TAKE/PROVIDE SAFETY MEAS TO PROTECT PUBLIC & INSTALL PUBLIC PROTECTION @ EXP2 N. MAKE REPAIR
#FA1102DD
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (4) · C 2 · B 2 · A 0
IssuedClassViolationCorrect by
Mar 9, 2026CApt 2G · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 13, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 3rd STORY, 1st APAApr 4, 2026
Mar 9, 2026BApt 2G · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SLIDE BOLT CAPABLE OF BEING PAD LOCKED AT DOOR IN THE ENTRANCE LOCATED AT APT 2G, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTApr 13, 2026
Mar 9, 2026C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT COMPACTOR CLOSET DOOR AT PUBLIC HALL, 3rd STORYMar 15, 2026
Jun 20, 2024BApt 4D · § 27-2005 HMC: REFIT DOOR TO FRAME IN THE ENTRANCE LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM SOUTH AT WESTJul 25, 2024

Issued in the last 120 days

DateSourceWhatNow
Jul 7, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT WINDOW STOOLS IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18690363 ISSUED 07-MAR-26 HAS BEEN UPGRADED TO CLASS B PER ADMIClosed
Jul 7, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT WINDOW STOOLS AT 1ST WINDOW FROM SOUTH AT WEST IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18690365 ISSUED 07-MAR-26 HAS Closed
Jul 7, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT WINDOW STOOLS IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18690364 ISSUED 07-MAR-26 HAS BEEN UPGRADED TO CLASS B PER ADMIClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 9:00 AM ET. BBL 2043230035.