Bronx · Block 3162 · Lot 29 · 10453

2195 Grand Concourse

6 floors · 55 apartments · 67,842 sq ft · built 1940 · class D7 · owner of record: 2195 Grand Concourse Realty Llc

18open violations
$10,000ECB/OATH penalties owed
5HPD class C (immediately hazardous)
68dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 67,842 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 189 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 189 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 312 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1164 days
Next cycle year 2029
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3162). Agency page

Dec 31, 2032
in 2260 days
Next due 2032
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-07 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $10,000 owed
IssuedViolationHearingBalance
Apr 21, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION I OBSERVED AT EXP #1 EAST (1)HAIRLINE CRACKED BRICK AT WINDOW SPANDRELS MUTLI LOC. (2)CRACKED/BROKEN WINDOW GLASS 2FL.-EXP
#35693676M
Dec 15, 2026
$5,000
Apr 21, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXP #4 NORTH-OBJECTS ON FIRE ESCAPE 4TH FL. REMEDY: REMOVE ALL OBSTRUCTIONS FROM ALL FIRE ESCAPES.
#35693677Y
Dec 15, 2026
$1,250
Jul 5, 2024Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIO BUILDING FACADE AND APPURTENANCES. NOTE ATTIME OF INSPECTION OBSERVED AT ALL EXPOSURES MULTIPLE AREAS OF STEP CRACKS AT MULTIPLE DIFFERENT LEVEL OF EACH FACADE. AT EXPOSURE #1 OBSERV
#35685368K
Nov 16, 2026
PENDING
$2,500
Jul 5, 2024Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE AT TIME OF INSPECTION OBSERVED OBJECTS ON FIRE ESCAPE AT EXPOSURE #2, 3, 4. REMEDY: REMOVE OBSTRUCTION.
#35685369M
Nov 16, 2026
$1,250
DOB (3)
IssuedViolationStatus
Sep 12, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00055
DOB VIOLATION - ACTIVE
Jul 5, 2024CONSTRUCTION
EMERGENCY WORK ORDER DUE TO HAZARDOUS MATERIAL OBSERVED.NOTE AT TIME O F INSPECTION OBSERVED HAZARDOUS MATERIAL.OBSERVED AT EXP1,4,2 MULTIPLE STEP CRACKS AND LOOSE FACE OF BRICKS.OBSERVED STEP CRACLS FROM WINDOW SILL TO WINDOW LINTEL.REMEDY:IMMEDIATELY REMOVE HAZARDOUS MATERIAL NOT ED.PROVIDE SAFETY
#FA20502DO
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2101676
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Sep 12, 2024AEUHAZ FTC-AEU-HAZ
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (12) · C 5 · B 5 · A 2
IssuedClassViolationCorrect by
Apr 9, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE VESTIBULE DOORApr 23, 2026
Jan 26, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR HINGES AT VESTIBULE DOOR IN THE PUBLIC HALL LOCATED AT PUBLIC PARTS, 1st STORYFeb 9, 2026
Aug 4, 2025B§ 27-2005 ADM CODE PROVIDE RE-ENTRY BY MEANS OF UNLOCKABLE SLIDE BOLT OR HOOK INSTALLED ON DOOR THAT ALLOWS RE-ENTRY FROM ROOF TO PUBLIC HALL BULKHEAD AT 2nd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY, SECTION ''SOUTH''Sep 8, 2025
Aug 4, 2025C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT 2ND FROM NORTH AT EAST LOWER WINDOW SASH AT PUBLIC HALL, 6th STORY, SECTION ''SOUTH''Aug 10, 2025
Aug 4, 2025A§ 27-2022 ADM CODE POST A SIGN INDICATING HOURS OF COLLECTION AND METHOD OF COLLECTION OF WASTE MATERIAL WHERE DUMBWAITER SERVICE IS NOT PROVIDED. AT PUBLIC HALL, 1st STORYNov 7, 2025
May 20, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AT PUBLIC HALL, 1st STORYAug 23, 2025
Feb 7, 2023C§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKSET AT FIRE DOOR [ FROM SOUTH TO NORTH SECTION] AT PUBLIC HALL, 3rd STORYFeb 13, 2023
Apr 23, 2020CApt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 2C, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTMay 14, 2020
Oct 1, 2018BApt 3H · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE BATHROOM LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHNov 5, 2018
Oct 1, 2018BApt 3H · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK IN THE ENTRANCE LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHNov 5, 2018
Sep 26, 2018BApt 3H · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOct 31, 2018
Sep 26, 2018BApt 3H · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOct 31, 2018

Issued in the last 120 days

DateSourceWhatNow
Aug 13, 2026ECBConstruction: FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 EAST-CRACKED BRICK,-EXP #2 SOUTH-DEFECTIVE MORTAR JOINT, PARAPET LEVEL BY LOUVER.-EXP #2 SOUTH-DEFECTIVClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 4:53 PM ET. BBL 2031620029.

Look up another building