8 floors · 37 apartments · 30,233 sq ft · built 2025 · class D3 · owner of record: 2183-2187 Ocean Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 68 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-04-29 (Accepted). Agency page | Dec 31, 2026 in 68 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 84 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 30,233 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 189 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 189 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 15 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 433 days | Next cycle year 2027 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 851 days | Filing window not open yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 29, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, EXTERIOR FACADE WORK WAS FOUND COMPLETED. COMPLAINT NO. 3A53086 RESULTED IN A PARTIAL STOP WORK ORDER DIRECTING ALL FACADE WORK TO STOP SITE CONDITIONS INDICATE FACADE WORK WAS PERFORMED #39554753M | Dec 1, 2026 | $10,000 |
| Mar 18, 2026 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING TOP OFF, I OBSERVED WORKERS INSTALLING BALCONY RAILS AT EXPOSURE #1&3 AND AT EXPOSURE #1 PIPE SCAFFOLD IN PLACE NOT FOLLY PLANK, NO GUARDRAILS, NO SAFETY N #39551961N | Feb 23, 2027 | $5,000 |
| Mar 18, 2026 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING TOP OFF, I OBSERVED WORKERS INSTALLING BALCONY RAILS AT EXPOSURE #1&3 AND AT EXPOSURE #1 NO PEDESTRIAN PROTECTION WAS PROVIDED. FAILURE TO PROVIDE AND MAIN #39551962P | Feb 23, 2027 | $4,800 |
| Mar 18, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING TOP OFF, I OBSERVED WORKERS INSTALLING BALCONY RAILS AT EXPOSURE #1&3 WITH NO FALL ARREST SYSTEM AND LIFE LINE IN PLACE FOR SAFETY MEASURES TO PREVENT THEM #39551963R | Feb 23, 2027 | $5,000 |
| Mar 18, 2026 | Unknown CLASS - 1 BC 3307.2.1 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING TOP OFF, I OBSERVED STORAGE CONTAINER ON STREET AT EXPOSURE #1, UPON REQUEST FOR DOT PERMIT TO OCCUPY STREET NONE WAS PRESENTED OR AT JOBSITE. #39551960L | Feb 23, 2027 | $5,000 |
| Mar 11, 2026 | Unknown CLASS - 2 MISCELLANEOUS VIOLATIONS. BC3303.7.2-DURING MY INSPECTION OF A 8 STORYNB ACTIVE JOB SITE, I OBSERVED THAT THE FIRE EXTINGUISHERS WERE INADEQUATE, WITH ISSUES SUCH AS MISSING SAFETY PINS/DAMAGE. ADDITIONALLY, AL #39551554X | Apr 8, 2027 DEFAULT | $2,530 |
| Mar 11, 2026 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO HANDRAILS. DURING THE INSPECTION OF AN ACTIVE 8-STORY NB JOB SITE, IT WAS OBSERVED THAT HANDRAILS ON THE STAIRWELLS WERE MISS #39551552M | Apr 8, 2027 DEFAULT | $2,530 |
| Mar 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33. DURING MY INSPECTION OF AN ACTIVE 8-STORY NEW BUILDING JOB SITE, I REQUESTED THE QSP TO PROVIDE THE SWS DAILY LOG, SWS 6 MONTH INSPECTION #39551557L | Apr 8, 2027 DEFAULT | $1,280 |
| Mar 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ATTHE TIME OF INSPECTION AT THE ACTIVE JOB SITE OF 8 STORY NB, I OBSERVED THAT HOUSEKEEPING WAS NOT MAINTAINED. THE SITE WAS FULL OF CONSTRUCT #39551553Y | Apr 8, 2027 DEFAULT | $1,280 |
| Mar 11, 2026 | Construction CLASS - 2 FAILURE TO POST. NO SMOKING SIGNS AT CONSTRUCTION SITES PER FIRE CODE.DURING MY INSPECTION OF AN ACTIVE 8-STORY NB JOB SITE, I OBSERVED THATFLOOR NUMBER SIGNS, AND NO SMOKING SIGNS WERE MISSING. THE ABSENCE OF #39551556J | Apr 8, 2027 DEFAULT | $1,280 |
| Mar 11, 2026 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. DURING THE INSPECTION, IT WAS OBSERVED THAT THE SIDEWALK SHED AT EXP #1 WAS NOT PROPERLY MAINTAINED. DEBRIS AND CONSTRUCTION EQUIPMENT WERE PRESENT AND N #39551555H | Apr 8, 2027 DEFAULT | $2,430 |
| Jan 16, 2026 | Construction CLASS - 1 STOP WORK ORDER WAS ISSUED 10/6/25 NO WORK ENTIRE SITE ABOVE 75'. COMPARING PREVIOUS PICS TO CURRENT PICS. OBSERVED THE ENTIRE 8TH FLOOR WAS FRAMED OUT AND WINDOWS AND SHEET ROCK WAS INSTALLED. THE BULKHEAD ROO #39549235X | Mar 1, 2027 DEFAULT | $12,500 |
| Jan 2, 2026 | Unknown CLASS - 2 MISCELLANEOUS VIOLATIONS.BC 3303.12 AT THE TIME OF MY INSPECTION OF ANEIGHT-STORY NEW BUILDING,I OBSERVED THAT THE STRUCTURE EXCEEDS 75 FEETIN HEIGHT WITH NO ELEVATOR OR HOIST IN PLACE.THIS CONDITION CREATES A #39548640P | Jan 4, 2027 | $2,500 |
| Oct 6, 2025 | Unknown CLASS - 1 BC 3303.12 AT THE TIME OF MY INSPECTION OF AN EIGHT-STORY NEW BUILDING, I OBSERVED THAT THE STRUCTURE EXCEEDS 75 FEET IN HEIGHT WITH NO ELEVATOR OR HOIST IN PLACE. THIS CONDITION CREATES A HAZARD FOR FDNY PERSO #39545708Z | Mar 25, 2027 | $5,000 |
| Aug 15, 2025 | Site Safety CLASS - 1 AT THE TIME OF MY INSPECTION, BUILDING AT 3 FLOOR DECKING LEVEL, I OBSERVED 7 WORKERS ON JOBSITE INSTALLING SIDEWALK SHED AT EXPOSURE #1, UPON REQUEST FOR THERE SITE SAFETY ORIENTATION AND REFRESHER NONE WAS PR #39543735P | May 6, 2026 IN VIOLATION | $2,500 |
| Aug 15, 2025 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION, BUILDING AT 3 FLOOR DECKING LEVEL, I OBSERVED WORKERS INSTALLING REBAR AND SCAFFOLDING WITH NO OVERHEAD PROTECTION FOR ADJACENT PROPERTY COURTYARD AT EXPOSURE #2, ALSO NONE FOR EXP #39543737Z | Jan 19, 2027 | $5,000 |
| May 20, 2025 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING FULL DEMOLITION, I OBSERVED BUILDING DEMO TO APPROXIMATELY 5 TO 6 FEET ABOVE GRADE, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT THERE WERE NO NOTIFICAT #39540402N | Mar 12, 2026 IN VIOLATION | $2,500 |
| May 20, 2025 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION, I OBSERVED BUILDING DEMO TO APPROXIMATELY 5 TO 6 FEET ABOVE GRADE WITH AN EXCAVATOR ON TOP OF DEMOLITION DEBRIS, FOOTPRINT OF BUILDING, UPON REVIEW OF THE DEPARTMENT RECORD IT REVE #39540404R | Mar 12, 2026 IN VIOLATION | $5,000 |
| Apr 24, 2025 | Construction CLASS - 2 AT THE TIME OF INSPECTION, A FULL DEMOLITION OF A TWO-STORY BUILDING WAS OBSERVED IN PROGRESS, WITHOUT PROVIDING THE NECESSARY PROTECTIVE MEASURES FOR THE PEDESTRIANS. THE SIDEWALK SHED WAS NOT COMPLETELY INSTA #39539523L | Dec 28, 2026 DEFAULT | $5,000 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 8:35 AM ET. BBL 3068030087.