Brooklyn · Block 307 · Lot 29 · 11201

216 Court Street

3 floors · 2 apartments · 2,400 sq ft · built 1854 · class S2 · owner of record: 216 Court Street Llc

19open violations
$25,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
45dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 45 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 289 days
Required only if the owner doesn't live there
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-15 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8) · $25,000 owed
IssuedViolationHearingBalance
Aug 16, 2025Unknown CLASS - 2
OBSERVED ACTIVE SITE SIDEWALK SHED @EXP.1 WITH OVERLOADED CONSTRUCTION MATERIAL ON DECKING. 3307.6.5.4 STORAGE OR PLACEMENT OF MATERIAL ON TOP OF SIDEWALK SHED SHALL BE DESIGN TO SUPPORT THE MAXIMUM LOAD FOR ST
#39543812J
May 11, 2026
IN VIOLATION
$2,500
Aug 16, 2025Construction CLASS - 1
OBSERVE ACTIVE SITE WITHOUT AFTER HOUR VARIANCE PERMIT UNDER STRUCTURAL PERMIT # B011288832-I1-ST. STOP ALL WORK UNDER JOB # B011288832-I1-ST. MUST OBTAIN AFTER HOUR VARIANCE PERMIT PER CODE
#39543790H
Dec 11, 2026
PENDING
$2,500
Aug 16, 2025Construction CLASS - 2
OBSERVED ACTIVE SITE WORKING UNDER STRUCTURAL PERMIT # B01128832-I-ST. THE CONDITIONS NOTED UNDER PERMIT STATES THAT NO WORK MUST BE COMMENCE UNTIL THE GENERAL CONSTRUCTION PERMIT IS PERMITTED. STOP ALL WORK UN
#39543787R
Dec 11, 2026
PENDING
$1,250
Aug 16, 2025Unknown CLASS - 2
OBSERVED ACTIVE SITE WITH ERECTED SUPPORTED SCAFFOLD @ EXP. 1MISSING TOE-BOARDS, GUARDRAILS & NOT PROPERLY MAINTAIN PER CODE 3314.4.8 . STOP ALL USE OF SUPPORTED SCAFFOLD. MUST PROVIDE AND MAINTAIN TOE-BOARDS,
#39543811H
May 11, 2026
IN VIOLATION
$2,500
Jul 28, 2025Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED WITH EQUIPMENT, MATERIALS, DEBRIS THROUGHOUT CREATING UNSAFE CONDITION FOR PEDESTRIANS. STOP ALL WORK AND USE OF SIDEWALK SHED COMPLY WITH BC 3307.6.4.2.2 AND BC 33
#39542919P
Oct 1, 2025
DEFAULT
$5,000
Jul 28, 2025Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: DEBRIS FROM FACADE DEMOLITION THROUGHOUT SIDEWALK UNDER SIDEWALK SHED, CREATING UNSAFE CONDITION FOR PEDESTRIANS COULD GET SERIOUSLY INJURED. STOP ALL FACADE WORK, PROVIDE MEANS
#39542917L
Oct 1, 2025
DEFAULT
$5,000
Jul 28, 2025Unknown CLASS - 2
3301.6 AT TIME OF INSPECTION OBSERVED: WOOD SHORING SUPPORTING FACADE WALL ATTACHED TO TEMPORARY EQUIPMENT (SIDEWALK SHED AND SUPPORTED SCAFFOLDS) AT EXPOSURE#1, UPON REQUEST FOR DESIGN DRAWINGS, NONE WAS PROVI
#39542920M
Oct 1, 2025
DEFAULT
$5,000
Jul 28, 2025Construction CLASS - 2
AT TIME OF MY INSPECTION OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1 WITH SUPPORTED SCAFFOLD ON TOP, NO SHOWING ON DRAWINGS, CREATING AN UNSAFE CONDITION FOR PEDESTRIANS AND NEGATIVELY IMPACT ON STRUCTURE. STO
#39542918N
Apr 2, 2026
IN VIOLATION
$1,250
DOB (10)
IssuedViolationStatus
Aug 22, 2022CONSTRUCTION
FAILURE TO COMPLY W/COMMISSIONER'S ORDER#340783(070822FEU30603ZT)DATED 07/08/22 REQUIRING THE OWNER TO START BLDG REPAIRS UNDER PERMIT FOR FACADE CRACKS. AS OF 08/19/22 THERE ARE NO JOBS FILED IN BIS OR DOB NOW TO REPAIR THE BLDG. REMEDY:IMMED COMPLY W/COMMISSIONER'S ORDER #340783(070822FEU30603ZT)T
#FEU30603ZT
DOB VIOLATION - ACTIVE
Jul 8, 2022CONSTRUCTION
FAIL TO MAINTAIN-ATTACHD,3-STORY+CELLAR,WOOD FRAME W/MASNRY WALL,APPRX 20'W X 40'D,ON AN INTERIOR LOT APPRX 20'W X 77'D.THE EXP1 APPEARED TO HAVE VERTICAL & DIAGONAL CRACKS NEAR THE WINDOW LINTELS AND SILLS OWNR RTAIN NYSPE-EVALU ENTIRE BLDG & PREPARE/FILE RPR DWGS.RPRS START UNDR PRMT BY 8/1/22 & C
#FEU30603ZT
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#07540
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#12983
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#13399
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#12864
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#12491
DOB VIOLATION - ACTIVE
Jun 1, 1994LOCAL LAW 62/91 - BOILERS

#09005
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#25197
DOB VIOLATION - ACTIVE
Jun 1, 1993LOCAL LAW 62/91 - BOILERS

#09004
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
Jan 3, 2008Boiler LL6291
Active
Jan 19, 2007Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
Jun 1, 1994Boiler LL6291
Active
Jun 1, 1993Boiler LL6291
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 8:12 PM ET. BBL 3003070029.