Bronx · Block 3947 · Lot 55 · 10462

2155 St Raymond Avenue

3 floors · 72,215 sq ft · built 1927 · class W2 · owner of record: Church Of St Raymond

15open violations
$3,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
56dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 56 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-03-20 (Accepted). Agency page

Dec 31, 2026
in 56 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 72,215 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 177 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 177 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3947). Agency page

Dec 31, 2027
in 421 days
Next due 2027

Open violations

ECB / OATH (6) · $3,125 owed
IssuedViolationHearingBalance
Nov 1, 2021Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39022172R ISSUED ON 5/12/2020 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01(D)(2)AN ACCEPTABLE CERTIFIC
#37021967N
Mar 4, 2022
DEFAULT
$3,125
May 12, 2020Boilers CLASS - 2
CORROSION ON BLOW OFF PIPE AT FRONT OF BOILER-HW TEMP. GAGE DEFECTIVE-STOP LEFT ON BAROMETRIC DAMPER, GAS BURNING EQUIPM'T-CHEM. FEED PIPE UNCAPPED-CHECK VALVE LEAKING ON GAS TRAIN-NO SUPP'T ON SAFETY DISCH PIP
#39022172R
Jul 17, 2020
STIPULATION/IN-VIO
$0
Sep 28, 2015Plumbing CLASS - 2
FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.INSPECTION TIME:NOON ON 9-8-15,I OBSERVED AN ALTERED GAS SYSTEM INCLUDING GAS BOOSTER,BYPASS,AND GAS PIPING IN CELLAR.ADDITIONALLY,NEW PIPING WAS RUN FROM
#35141181P
Dec 4, 2015
IN VIOLATION
$0
Sep 28, 2015Plumbing CLASS - 2
GAS BEING SUPPLIED W/O INSPECTION AND CERTIFICATION BY DOB.INSPECTION TIMENOON ON 9-28-15, I OBSERVED IN ABOVE CITED PREMISES A NEW GAS BOOSTER CONSISTING OF GAS PIPING AND VALVES IN CELLAR.ADDITIONALLY,THERE
#35141182R
Dec 4, 2015
IN VIOLATION
$0
Sep 28, 2015Construction CLASS - 1
WORK W/O A PERMIT: INSTALLATION OF GAS BOOSTER AND GAS PIPING. INSPECTION TIME: NOON ON 9-28-15, I INSPECTED THE ABOVE CITED PREMISES.I OBSERVED IN CELLAR A NEW GAS BOOSTER SYSTEM INCLUDING BYPASS.ADDITIONALLY
#35141180N
Dec 4, 2015
IN VIOLATION
$0
May 14, 2015Construction CLASS - 1
WORK DOES NOT CONFORM TO CRUST DOCS & OR AMENDMENTS.IN CATHOLIC SCHOOL.OBSERVED ON MAY 14,2015 @2:00 PM HOT WATER HEATER GAS LINE HAS (FUTURE TEE) CONNECTION ILLEGAL.APP#220230532.REM:CONFORM WORK CONST DOCS &
#35115862L
Aug 21, 2015
DEFAULT
$0
DOB (6)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#07562
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#06819
DOB VIOLATION - ACTIVE
Aug 17, 2021ELEVATOR

#9027/705947
DOB VIOLATION - ACTIVE
Aug 14, 2020ELEVATOR

#9027/684412
DOB VIOLATION - ACTIVE
Aug 19, 2019ELEVATOR

#9027/660498
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#04914
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Jan 26, 2018Elevators ACC1
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 3:38 PM ET. BBL 2039470055.