3 floors · 72,215 sq ft · built 1927 · class W2 · owner of record: Church Of St Raymond
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 56 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-03-20 (Accepted). Agency page | Dec 31, 2026 in 56 days | 2 of 2 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 72,215 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 177 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 177 days | Annual filing |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3947). Agency page | Dec 31, 2027 in 421 days | Next due 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 1, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39022172R ISSUED ON 5/12/2020 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01(D)(2)AN ACCEPTABLE CERTIFIC #37021967N | Mar 4, 2022 DEFAULT | $3,125 |
| May 12, 2020 | Boilers CLASS - 2 CORROSION ON BLOW OFF PIPE AT FRONT OF BOILER-HW TEMP. GAGE DEFECTIVE-STOP LEFT ON BAROMETRIC DAMPER, GAS BURNING EQUIPM'T-CHEM. FEED PIPE UNCAPPED-CHECK VALVE LEAKING ON GAS TRAIN-NO SUPP'T ON SAFETY DISCH PIP #39022172R | Jul 17, 2020 STIPULATION/IN-VIO | $0 |
| Sep 28, 2015 | Plumbing CLASS - 2 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.INSPECTION TIME:NOON ON 9-8-15,I OBSERVED AN ALTERED GAS SYSTEM INCLUDING GAS BOOSTER,BYPASS,AND GAS PIPING IN CELLAR.ADDITIONALLY,NEW PIPING WAS RUN FROM #35141181P | Dec 4, 2015 IN VIOLATION | $0 |
| Sep 28, 2015 | Plumbing CLASS - 2 GAS BEING SUPPLIED W/O INSPECTION AND CERTIFICATION BY DOB.INSPECTION TIMENOON ON 9-28-15, I OBSERVED IN ABOVE CITED PREMISES A NEW GAS BOOSTER CONSISTING OF GAS PIPING AND VALVES IN CELLAR.ADDITIONALLY,THERE #35141182R | Dec 4, 2015 IN VIOLATION | $0 |
| Sep 28, 2015 | Construction CLASS - 1 WORK W/O A PERMIT: INSTALLATION OF GAS BOOSTER AND GAS PIPING. INSPECTION TIME: NOON ON 9-28-15, I INSPECTED THE ABOVE CITED PREMISES.I OBSERVED IN CELLAR A NEW GAS BOOSTER SYSTEM INCLUDING BYPASS.ADDITIONALLY #35141180N | Dec 4, 2015 IN VIOLATION | $0 |
| May 14, 2015 | Construction CLASS - 1 WORK DOES NOT CONFORM TO CRUST DOCS & OR AMENDMENTS.IN CATHOLIC SCHOOL.OBSERVED ON MAY 14,2015 @2:00 PM HOT WATER HEATER GAS LINE HAS (FUTURE TEE) CONNECTION ILLEGAL.APP#220230532.REM:CONFORM WORK CONST DOCS & #35115862L | Aug 21, 2015 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07562 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #06819 | DOB VIOLATION - ACTIVE |
| Aug 17, 2021 | ELEVATOR #9027/705947 | DOB VIOLATION - ACTIVE |
| Aug 14, 2020 | ELEVATOR #9027/684412 | DOB VIOLATION - ACTIVE |
| Aug 19, 2019 | ELEVATOR #9027/660498 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #04914 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 5, 2026, 3:38 PM ET. BBL 2039470055.