5 floors · 4 apartments · 6,662 sq ft · built 1920 · class S4 · owner of record: 214-216 5th Ave Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2025-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 20, 2008 | Plumbing Non-Hazardous GAS BEING SUPPLIED TO BLDG W/O INSPECTION AND ANTICIPATION BY THE DEPARTMENT HAZARDOUS RESEARCHED DOB RECORDS AND FOUND NO GAS AUTHORIZATION USE APPROVED FOR USE IN KITCHEN EQUIPMENT ON HVAC EQUIPMENT GAS METER #34623262M | Feb 9, 2009 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 4, 2011 | CONSTRUCTION #CN0601EQ | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 19, 2025 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Apr 30, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 3, 2026 |
| Jun 5, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 8, 2025 |
| Feb 19, 2010 | C | Apt 2 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, APARTMENT AT SOUTH | Feb 25, 2010 |
| Feb 19, 2010 | B | Apt 2 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2, 2nd STORY, APARTMENT AT SOUTH | Mar 26, 2010 |
| Feb 19, 2010 | B | Apt 2 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2, 2nd STORY, APARTMENT AT SOUTH | Mar 26, 2010 |
| Sep 17, 2009 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING , 100 WATTS REQUIRED. | Oct 22, 2009 |
| Apr 9, 2009 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED | May 14, 2009 |
| Jun 5, 2008 | B | Apt 3L · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY SOUTHAPT 3L ALVERADO. LOCATED AT APT 3L | Jul 10, 2008 |
| Jun 5, 2008 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE 1 STY PUBLIC HALL TO CELLAR METER ROOM. | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 2R · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED GAS PIPE AT WALL 2 STY SOUTHWEST APT 2R FOYER. LOCATED AT APT 2R | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-17.09, 18.01 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM GAS SPCEHTR KIT&FRNT RM 2 STY SOWEST APT 2R. | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 2 · D26-17.09, 18.01 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM HOT WATER HTR KITCHEN 2 STY SOWEST APT 2 R. LOCATED AT APT 2 | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3L · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS THRU OUT 3 STY SOUTH APT 3L. LOCATED AT APT 3L | Jul 10, 2008 |
| Jun 5, 2008 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 50 WATTS NIGHT INSPECTION. | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 2R · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 2 STY NORTH APT 2R. LOCATED AT APT 2R | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3L · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL SYSTEM FRONT ENTRANCE DOOR TO 3 STY SOUTH APT 3L. LOCATED AT APT 3L | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3L · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 3 STY SOUTH APT 3L. LOCATED AT APT 3L | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 3L · SECTION 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD 3 STY SOUTH APT 3L. LOCATED AT APT 3L | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 3R · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 3 STY NORTH APT 3R. LOCATED AT APT 3R | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 2R · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 2 STY NORTH APT 2R. LOCATED AT APT 2R | Jul 10, 2008 |
| Jun 5, 2008 | B | SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL 1 TO 2 STY PUBLIC HALL. | Jul 10, 2008 |
| Jun 5, 2008 | B | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTERS 2 STY PUBLIC HALL. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT MORTAR CLG REAR CELLAR. | Jul 10, 2008 |
| Jun 5, 2008 | A | SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION OPENING CREATED IN FLOOR CONVEYER BELT INSTALLED 1 STY TO CELLAR REAR STORE. | Sep 8, 2008 |
| Jun 5, 2008 | B | D26-17.09, 18.01 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM 3 STY NORTH APT KITCHEN. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-17.09, 18.01 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM 3 STY NORTH APT FRONT ROOM. | Jul 10, 2008 |
| Jun 5, 2008 | A | D26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING. | Sep 8, 2008 |
| Jun 5, 2008 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE SOUTH & NORTH AIR SHAFT TO BLDG. | Jul 10, 2008 |
| Mar 8, 2007 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED | Apr 17, 2007 |
| Nov 14, 2006 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING , 100 WATTS MINIMUM REQUIRED | Dec 24, 2006 |
| Jul 28, 2006 | A | SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DOORS AIR SHAFT SEALED WITH MASONRY CELLAR NORTH CENTER. | Nov 24, 2006 |
| Jul 28, 2006 | A | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALLUSTERS STAIR 3 STY PUBLIC HALL TO ROOM. | Nov 24, 2006 |
| Jul 28, 2006 | A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS 1 STY PUBLIC HALL VESTIBULE. | Nov 24, 2006 |
| Jul 28, 2006 | A | Apt 3L · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED CEILINGS 3 STY SOUTH APT 3L KITCHEN AND CENTER ROOM. , SECTION '' '' | Nov 24, 2006 |
| Jun 28, 2005 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS. LIGHTS NOT ON. | Aug 7, 2005 |
| Sep 25, 1990 | B | Apt 3R · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SMOKE DETECTOR INSTALLED 3 STY NORTH APT 3R KITCHEN. LOCATED AT APT 3R | Nov 12, 1990 |
| Sep 25, 1990 | B | Apt 3R · SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILING 3 STY NORTH APT 3R 2ND ROOM FROM FRONT. LOCATED AT APT 3R | Nov 12, 1990 |
| Sep 25, 1990 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTERBOARD CEILINGS THRU OUT CELLAR. | Nov 12, 1990 |
| Sep 25, 1990 | B | Apt 2R · SECTION 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 2 STY NORTH APT 2R. LOCATED AT APT 2R | Nov 12, 1990 |
| Sep 25, 1990 | B | SECTION 27-2005 ADM CODE PROVIDE GUARDRAIL AIR SHAFT ROOF CENTER AT NORTH & SOUTH. | Nov 12, 1990 |
| Sep 25, 1990 | B | Apt 3R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING 3 STY NORTH APT 3R 2ND ROOM FROM FRONT. LOCATED AT APT 3R | Nov 12, 1990 |
| Sep 25, 1990 | B | SECTION 27-2044 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS TOP CELLAR 1 STY PUBLIC HALL STAIR. | Nov 12, 1990 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)