2 floors · 2,250 sq ft · built 1931 · class O2 · owner of record: Perfect Timing
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-01-12 (Accepted). Agency page | Dec 31, 2026 in 58 days | 2 of 2 without an accepted 2026 report yet |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 423 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 12, 2021 | Boilers CLASS - 2 WILLIAMSON BLR GWA140 140,000 BTUS,FIRE PROOF DOOR,REMOVE STORAGE,MISSING DISCHG FOR BLR,WTR HTR & BACKFLOW,NEED SUPPORT FOR EXP TNK,EXP,WIRES,NEED CHIMNEY CAP #39044273N | Aug 31, 2021 DEFAULT | $1,562 |
| Mar 11, 2020 | Boilers CLASS - 2 B 254-36 FOUND A WILLIAMSON GAS FIRED BOILER SERIAL# CP 7622424 NOT REGISTERED, REGISTER THE BOILER AND SUBMIT A CERTIFICATE OF CORRECTION #39019506K | Jan 19, 2021 DEFAULT | $1,562 |
| Dec 11, 2018 | Construction CLASS - 1 B101. FOUND WILLIAMSON GAS FIRED BOILER INSTALLED WITHOUT A PERMIT. OBTAIN PROPER PERMITS AND SUBMIT A CERTIFICATE OF CORRECTION. #32098159Z | Apr 2, 2019 DEFAULT | $6,250 |
| Dec 11, 2018 | Boilers CLASS - 2 36,15,34A,38,50B,5B,16,36,50A,50C. B254-36 FOUND WILLIAMSON GAS FIRED BOILER NOT REGISTERED 50 A) NO STORAGE IN BOILER ROOM B) NO DISCHARGE PIPES ON ALL RELIEF VALUES C) NOT ENOUGH PIPE SUPPORT. REGISTER THE B #32098158R | Apr 2, 2019 DEFAULT | $1,562 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 11) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 10:53 AM ET. BBL 4062880013.