Queens · Block 10626 · Lot 1 · 11428

213-09 213 Street

5 floors · 150,150 sq ft · built 1931 · class W1 · owner of record: Nyc Department Of Education

16open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
48dto Energy audit and retro-commissioning (2026)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 48 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 10626). Agency page

Dec 31, 2026
in 48 days
Due this year
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-16 (Accepted). Agency page

Dec 31, 2026
in 48 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 150,150 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 169 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 169 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1144 days
Next cycle year 2029

Open violations

ECB / OATH (14)
IssuedViolationHearingBalance
Feb 9, 2026Construction CLASS - 2
REISSUE#35676593M FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:UPON INSPECTION CELLAR LEVEL FOUNDING WALL AT 92ND AVE HAS BECOME POROUS ALLOWING THE RAINWATER INTO ELECTRICAL SWITCHES GEAR ROOM.R
#35728674X
Mar 12, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:UPON INSPECTION STAIRCASE F 5TH FLOOR GLASS PANEL CRACKED AND CAFETERIA SMOKE DOORS(2 DOORS).REM:REPAIR AND/OR REPLACE.
#35728673Y
Mar 12, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:UPON INSPECTION FIRE ROOFED SMOKE DOORS NOT PROPERLY CLOSING THROUGH MISSING DOOR CLOSURES,BINDING OR STRIKE PLATE ON DOORS 111,112,313,311,310A,306,3
#35728668J
Mar 12, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8(2014 CODE)27-371;BC 1008.1.9(2014 CODE)BC 1010.1.8(2022 CODE)BC 1010.1.9(2022 CODE).NOTED:UPON INSPEC
#35728669L
Mar 12, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 2
REISSUE#35692395L FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381 AND EXIT SIGNS.NOTED:BOX 18,AND GIRLS GYM/BALB OUT BOX 93
#35728670Z
Mar 12, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.NOTED:16 CARS IN SCHOOL YARD CONTRARY TO 6 AVAILABLE SPOTS FROM COFO.REM:DISCONTINUE ILLEGAL USE OR AMEND COFO.
#35728671K
Mar 10, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 2
REISSUE#35724731P FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:UPON INSPECTION EXPOSURE 2 168TH ST AND EXPOSURE 3 CORNER BY SCHOOL YARD A VERTICAL CRACK AND DELAMINATING BRICK FACE.REM:REPAIR AND
#35728672M
Mar 12, 2026
POP/IN-VIO
$0
Feb 11, 2025Construction CLASS - 2
REISSUE#35676592K FAILURE TO MAINTAIN EMG LIGHTS NOT WORK IN AUDITORIUM 1 LIGHT AND STAIRCASE BEHIND STAGE.REM:REPAIR/REPLACE LIGHTING.
#35692395L
Jun 17, 2025
POP/IN-VIO
$0
Feb 9, 2024Construction CLASS - 2
REISSUE#35663188X FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:THE FOLLOWING EMERGENCY EXIT LIGHTING FOUND INOPERA
#35676592K
Apr 22, 2024
POP/IN-VIO
$0
Feb 9, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:AT CELLAR LEVEL FOUNDATION WALL AT 92 AVENUE SIDE HAS BECOME POROUS ALLOWING THE RAINWATER INTO THE CELLAR.REM:MAINTAIN EXTERIOR WALL.
#35676593M
Apr 22, 2024
POP/IN-VIO
$0
Jan 13, 2023Construction CLASS - 2
REISSUE #35502902R FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.ILLUMINATED FOR EXIT DISCHARGES & PUBLIC CORRIDORS PER BC 1006.1; 27-381 @ 5TH FL GYM.REMEDY:COMPLY WITH CODE.
#35663188X
May 9, 2023
POP/IN-VIO
$0
Apr 6, 2022Construction CLASS - 2
REISSUED:35502362P FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 106.1;27-381.NOTED:EM VARIOUS LOCATIONS THE EMERGENCY LIGHTS ARE INOPE
#35644496Y
Oct 25, 2022
POP/IN-VIO
$0
Jan 28, 2021Construction CLASS - 2
REISSUE#35502902R DATE OF ISSUE 8-26-2020 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER ILLUMINATION FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDOR PER BC 1006.1;27-381. AT 1ST FL AUDITORIUM LIGHT NO 32 1 PLAC
#35502362P
May 18, 2021
POP/IN-VIO
$0
Aug 26, 2020Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER ILLUMINATION FOREXIT DESCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.AT 5TH FLOORGYMNASIUM 1 EMERGENCY LIGHT(LEFT SIDE)AT 3RD FLOOR BOYS GYMNASIUM ENTR
#35502902R
Nov 24, 2020
POP/IN-VIO
$0
DOB (1)
IssuedViolationStatus
May 5, 2001CONSTRUCTION

#11BK07
VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 13, 2026, 8:51 PM ET. BBL 4106260001.