| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-13 (Accepted). Agency page | Dec 31, 2026 in 43 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 408 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 2, 2026 | Construction CLASS - 2 AT THE TIME IF INSPECTION 5:00AM, I OBSERVED NO LIGHTING ON SWS AT EXP1. THIS CREATING DARK CONDITIONS BENEATH THE SIDEWALK SHED. THE LACK OF ILLUMINATION CREATES SLIP, TRIP, AND FALL HAZARDS FOR PEDESTRIANS AN #39558649K | Nov 12, 2026 PENDING | $2,400 |
| Sep 2, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION OF A 6-STORY MULTI-DWELLING, I OBSERVED AN ERECTED SIDEWALK SHED EXP1. A REVIEW OF DOB RECORDS DETERMINED THE SIDEWALK SHED PERMIT WAS ISSUED 2/09/2024, EXPIRED 2/09/2025, AND HAD NOT #39558650H | Nov 12, 2026 PENDING | $1,250 |
| Jul 8, 2026 | Unknown CLASS - 2 TEMP CONSTRUCTION EQUIP/INSTALLATION ON SITE EXPIRED PERMIT (SHED). ATOI I OBSERVED THE SIDEWALK SHED PERMIT IS EXPIRED AT PRESENT TIME., RENEW PERMIT #39195297X | Sep 17, 2026 DEFAULT | $6,250 |
| Jul 8, 2026 | Unknown CLASS - 2 ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN APT #9 THE INSTALLATION OF STACKABLE WASHER / DYER 30 AMP. CHECKED BIS / DOB NOW WAS NOT ON PERMITED WORK M363198 ALL WORK MUST BE FILLED 27-3018(B), OBTAIN PERMIT #39195274N | Sep 17, 2026 DEFAULT | $6,250 |
| Jul 8, 2026 | Unknown CLASS - 2 FAILURE TO PROVIDE/MAINTAIN SUFFICIENT ACCESS/WORK SPACE ABOUT ELECTRICAL EQUIPMENT. OBSERVED IN THE BASEMENT THE BLOCKING OF THE MAIN ELECTRICAL SERVICE EQUIPMENT WITH LADDERS, TABLES. EQUIPMENT MUST BE ACCESS #39195273L | Sep 17, 2026 DEFAULT | $2,500 |
| Jul 8, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ATOI I OBSERVED CRACKS THROUGHOUT FACADE AT EXPOSURE 1 PARAPET, 2, 3 BELOW WINDOW SILL AND ABOVE WINDOW LINTEL'S, 4 AT PARAPET, ALSO I OBSERVED CRACKS AND #39195296Y | Sep 17, 2026 DEFAULT | $12,500 |
| Jul 8, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN. OBSERVED IN THE BASEMENT THE CON EDISON SPLICE BOX IS IN A STATE OF CORROSION THE SERVICE CONDUCTOR FEEDERS ARE EXPOSED DUE TO WATER DAMAGE ROTTING THE TROUGH COMPLETELY. HIGH RISK OF ELECT #39195270X | Sep 17, 2026 DEFAULT | $12,500 |
| Jul 8, 2026 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN APT #16 IN THE KITCHEN REGULAR RECEPTACLES NO GFCI INSTALLED ALSO IN THE LIVING RM CEIL #39195272J | Sep 17, 2026 DEFAULT | $8,000 |
| Jul 8, 2026 | Construction CLASS - 1 ATOI OBSERVED IN BASEMENT BOILER IS LEAKING AND NOT MAINTAINING TEMP, HOUSE TRAP IS CLOGGED AND PVC PIPE IS BEING USED PER PC 102.3 MAINTENANCE INSTALLATIONS BOTH EXISTING AND NEW AND PARTS THEREOF SHALL BE MAI #39195303N | Sep 17, 2026 DEFAULT | $12,500 |
| Jul 8, 2026 | Unknown CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED THE SIDEWALK SHED HAS NO GROUND. THE J-CORD FEEDING THE SHED THE GROUND IS CUT AND NOT USING THE PROPER FITTING THERE IS EXPOSED WIRES AT POINT OF CONNECTION. ALL #39195271H | Sep 17, 2026 DEFAULT | $24,000 |
| Jul 8, 2026 | Construction CLASS - 1 ATOI OBSERVED ON ROOF CAP FOR CHIMINEY IS MISSING. DEBRIS CAN NOW ENTER AND CREATE A FIRE HAZARD.PER PC 102.3 MAINTENANCE INSTALLATIONS BOTH EXISTING AND NEW AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPER #39195304P | Sep 17, 2026 DEFAULT | $12,500 |
| Dec 23, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF 5 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE WITHOUT INFORMATION PANEL CAUSING HAZARDOUS CONDITIONS.PROVIDE INFORMATION PANEL #39548378Z | May 7, 2026 DEFAULT | $6,250 |
| Aug 12, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT I OBSERVED UNDERSIDE OF SIDEWALK SHED A NOT ILLUMINATED AS PER 3307.6.4.8. THIS CREATES A HAZARDOUS CONDITION FOR PUBLIC WALKING UNDERNEATH WHILE DARK AND NOT BEIN #39543547H | Oct 16, 2025 DEFAULT | $10,000 |
| Aug 12, 2025 | Unknown CLASS - 2 OBSERVED A SIDEWALK SHED INSTALLED AT LOCATION 212 EAST 105 STREET NOT IN COMPLIANCE WITH BUILDING CODE. LIGHTS ARE OUT UNDERNEATH SHED CREATING DARK AND UNSAFE CONDITIONS. UPON CHECKING DEPARTMENT RECORDS SHED #39543548J | Oct 16, 2025 DEFAULT | $6,250 |
| Jan 16, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH LIGHTING NOT IN OPERATING CONDITION CAUSING HAZARDOUS CONDITIONS.PROVIDE LIGHTING DUSK-DAWN #39536033P | Mar 27, 2025 DEFAULT | $10,000 |
| Nov 25, 2024 | Construction CLASS - 2 AT TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH NO INFORMATION PANEL ON PARAPET CAUSING HAZARDOUS CONDITIONS.PROVIDE INFORMATION PANEL AS REQUIRED #39534665Y | Feb 27, 2025 IN VIOLATION | $1,250 |
| Nov 25, 2024 | Construction CLASS - 2 AT TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH LIGHTING NOT IN OPERATING CONDITION CAUSING HAZARDOUS CONDITIONS.PROVIDE LIGHTING AS REQUIRED #39534664M | Feb 27, 2025 IN VIOLATION | $2,400 |
| Jan 24, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS. OBSERVED AT EXPOSURE #1 PARAPET LEVEL FACADE BULGING AND STUCCO PEELING OF BUILDING AT EXPOSURE #2. DEBRIS FALLING DOWN., MAINTAIN EXTERIOR BUILDING WALL #39104211J | Apr 4, 2024 DEFAULT | $12,500 |
| Issued | Violation | Status |
|---|---|---|
| Jan 24, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING WALLS. OBSERVED AT EXPOSURE #1 AND 2 FACADE IN A STATE OF DISREPAIR. #24-00200 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #07256 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 29, 2026 | B | Apt 6 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 19048776 ISSUED 23-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE | Dec 3, 2026 |
| Sep 28, 2026 | C | Apt 18 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 18, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 27, 2026 |
| Sep 28, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM | Oct 4, 2026 |
| Sep 2, 2026 | B | Apt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 7, 2026 |
| Sep 2, 2026 | B | Apt 8 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 7, 2026 |
| Sep 2, 2026 | B | Apt 8 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 7, 2026 |
| Sep 2, 2026 | C | Apt 8 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 28, 2026 |
| Sep 2, 2026 | B | Apt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 7, 2026 |
| Sep 2, 2026 | A | Apt 8 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 6, 2026 |
| Aug 7, 2026 | C | Apt 16 · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE PRESUMED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH | Aug 31, 2026 |
| Aug 6, 2026 | C | Apt 16 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, EAST WALL, WEST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WE | Aug 30, 2026 |
| Aug 4, 2026 | C | Apt 16 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 30, 2026 |
| Jul 15, 2026 | B | Apt 23 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 23, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 19, 2026 |
| Jul 15, 2026 | B | Apt 23 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB-FLOOR IN THE KITCHEN LOCATED AT APT 23, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 19, 2026 |
| Jul 15, 2026 | B | Apt 23 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW IN THE 2nd ROOM FROM NORTH LOCATED AT APT 23, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 19, 2026 |
| Jul 15, 2026 | A | Apt 7 · § 27-2005 HMC: REFIT DOOR AT ENTRANCE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 18, 2026 |
| Jul 15, 2026 | B | Apt 7 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT UPPER SASH WINDOW IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 19, 2026 |
| Jul 15, 2026 | B | Apt 7 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB-FLOOR IN THE KITCHEN LOCATED AT APT 7, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 19, 2026 |
| Jul 15, 2026 | B | Apt 7 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 7, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 19, 2026 |
| Jul 15, 2026 | B | Apt 7 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE UPPER SASH WINDOW IN THE BATHROOM LOCATED AT APT 7, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 19, 2026 |
| Jul 15, 2026 | A | Apt 7 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 7, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 18, 2026 |
| Jul 10, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT FIRE PASSAGE WAY | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 3 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT REAR YARD | Aug 14, 2026 |
| Jul 10, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING THROUGHOUT AT CELLAR | Aug 14, 2026 |
| Jul 10, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Aug 5, 2026 |
| Jul 10, 2026 | B | Apt 16 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE METAL BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 10, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BALCONIES AND ALL COMPONENTS AT BUILDING REAR FIRE ESCAPE | Oct 13, 2026 |
| Jul 10, 2026 | B | Apt 16 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 16 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD CABINET AT EAST WALL IN THE KITCHEN LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 8, 8th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 8, 8th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 3 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE UPPER GLASS WINDOW IN THE 4th ROOM FROM NORTH LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 3 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 16 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 10, 2026 | B | Apt 16 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 10, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DECORATIVE CONCRETE OVERHANG AT BUILDING FRONT ENTRANCE DOOR , 1st STORY | Jul 16, 2026 |
| Jul 10, 2026 | B | Apt 16 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 14, 2026 |
| Jul 7, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DECORATIVE CONCRETE OVERHANG AT BUILDING FRONT ENTRANCE DOOR , 1st STORY | Jul 13, 2026 |
| Jul 7, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT FIRE PASSAGE WAY | Aug 11, 2026 |
| Jul 7, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES, ALL BALCONIES AND ALL COMPONENTS AT BUILDING REAR AT FIRE ESCAPE | Oct 10, 2026 |
| Jul 7, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME AT BULKHEAD | Jul 21, 2026 |
| Jul 7, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Aug 2, 2026 |
| Jul 1, 2026 | B | Apt 6 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Jul 1, 2026 | B | Apt 6 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Jul 1, 2026 | B | Apt 6 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Jul 1, 2026 | B | Apt 6 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Jul 1, 2026 | B | Apt 11 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT CEILING, SOUTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 11, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Jul 1, 2026 | C | Apt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 27, 2026 |
| May 29, 2026 | B | Apt 24 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE FOYER LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 3, 2026 |
| May 29, 2026 | B | Apt 24 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 3, 2026 |
| May 29, 2026 | B | Apt 24 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING , EAST AND SOUTH WALLS IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 3, 2026 |
| May 29, 2026 | B | Apt 24 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, EAST , NORTH AND WEST WALLS IN THE KITCHEN LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 3, 2026 |
| May 29, 2026 | B | Apt 3 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2026 |
| May 29, 2026 | B | Apt 6 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30 SQFT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2026 |
| May 29, 2026 | B | Apt 24 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE DOOR AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 3, 2026 |
| May 29, 2026 | B | Apt 24 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30 SQFT AT CEILING AND ALL WALLS , APPROX 8 SQFT AT CEILING, 6 SQFT AT SOUTH , 2 SQFT AT EAST AND 1SQFT AT NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WES | Jul 3, 2026 |
| May 29, 2026 | B | Apt 24 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR AT ENTRANCE IN THE BATHROOM LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 3, 2026 |
| May 29, 2026 | A | Apt 24 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 24, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 1, 2026 |
| May 29, 2026 | B | Apt 6 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2026 |
Showing 60 of 132. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 19048776 ISSUED 23-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 28, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 18, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 28, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM | Open |
| Sep 2, 2026 | ECB | Construction: AT THE TIME IF INSPECTION 5:00AM, I OBSERVED NO LIGHTING ON SWS AT EXP1. THIS CREATING DARK CONDITIONS BENEATH THE SIDEWALK SHED. THE LACK OF ILLUMINATION CREATES SLIP, TRIP, AND FALL HAZARDS FOR PEDESTRIANS AN | Open |
| Sep 2, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION OF A 6-STORY MULTI-DWELLING, I OBSERVED AN ERECTED SIDEWALK SHED EXP1. A REVIEW OF DOB RECORDS DETERMINED THE SIDEWALK SHED PERMIT WAS ISSUED 2/09/2024, EXPIRED 2/09/2025, AND HAD NOT | Open |
| Sep 2, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 2, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 2, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 2, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 2, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 2, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 31, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR LEADING TO EAST YARD AT PUBLIC HALL, 1st STORY | Closed |
| Aug 7, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM NORTH AT WEST, THE KITCHEN , THE BATHROOM , THE FOYER LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
| Aug 7, 2026 | HPD C | § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE PRESUMED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH | Open |
| Aug 6, 2026 | HPD C | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, EAST WALL, WEST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WE | Open |
| Aug 4, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUBFLOOR IN THE FOYER LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
| Aug 4, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE FOYER LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
| Aug 4, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 16, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
| Aug 4, 2026 | HPD B | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT WEST WALL AT PUBLIC HALL, 1st STORY | Closed |