Brooklyn · Block 1749 · Lot 1 · 11206

211 Throop Avenue

3 floors · 85,953 sq ft · built 1959 · class W1 · owner of record: Nyc Department Of Parks And Recreation

19open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
183dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 85,953 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 183 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 183 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 793 days
Next cycle year 2028
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1749). Agency page

Dec 31, 2029
in 1158 days
Next due 2029
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-05 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (15)
IssuedViolationHearingBalance
May 21, 2026Construction CLASS - 2
REISSUE ECB#35719601K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:AT 1ST FL CAFETERIA EMERGENCY LIGHTS NOT WORKIN
#35731833L
Jun 15, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
EXIT DOOR NOT SELF CLOSING.NOTED:AT 1ST FL CLASSROOMS 101 AND 102 TO EXIT 6,GYM DOORS IN DISREPAIR NOT CLOSING WHEN TESTED.REM:REPAIR/REPLACE DOORS.
#35731837Z
Jun 15, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1;27-371(J).NOTED:AT MAIN ENTRANCE AND 1ST FL THRU 3RD FL FLOORS INSTALLED/USED HOOK/KICK DOOR STOPPERS T
#35731835P
Jun 15, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
REISSUE ECB#35719600Z FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED AT ROOF PARAPET NOT INSTALLED/PROVIDED WITHOUT REQUIRED HEIGHT/RAILS.REM:REPAIR AND/OR REPLACE.
#35731834N
Jun 15, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.NOTED:AT 1ST FL CLASSROOM SPA 101 AND 102 EXIT 6 NOT INSTALLE
#35731836R
Jun 15, 2026
POP/IN-VIO
$0
Apr 30, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 1ST FLOOR AUDITORIUM 3
#35719601K
Jun 12, 2025
POP/IN-VIO
$0
Apr 30, 2025Construction CLASS - 2
REISSUE #35677457M DATE OF ISSUE: 04-23-2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER AT THE TIME OF INSPECTION NOTED AND OBSERVED AT ROOF LEVEL BULKHEAD ACCESS TO 3 STORY BUILDING ROOF WITH PARAP
#35719600Z
Jun 12, 2025
POP/IN-VIO
$0
Apr 23, 2024Construction CLASS - 2
REISSUE#35671674L FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT TIME OF MY INSPECTION I OBSERVED AT THE ROOF LEVEL SEENING 22"FLOOR IN HEIGHT WILL BULKHEAD ACCESS TO 16 3 STORY BUILDING ROOF WILL 16
#35677457M
May 13, 2024
POP/IN-VIO
$0
Feb 9, 2023Construction CLASS - 2
RE-ISSUE #35643520K (4/29/22) FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED AT ROOF LEVEL BULKHEAD ACCESS TO 3 STORY BUILDING ROOF WITH PARAPET UNDER MINIMUM REQUIRED HEIGHTS.REMEDY:REPAI
#35671674L
May 10, 2023
POP/IN-VIO
$0
Apr 29, 2022Construction CLASS - 2
RE-ISSUED #35556029P FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED AT ROOF LEVEL ROOF EXCEEDING 22 FT IN HEIGHT WITH BULKHEAD ACCESS HAS PARAPET WALL THAT IS TOO LOW NOT IN COMPLIANCE WIT
#35643520K
Oct 12, 2022
POP/IN-VIO
$0
Apr 19, 2021Construction CLASS - 2
REISSUE#35415284N-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT ROOF LEVEL AT PARAPET WALL HEIGHT IS LOWER THAN REQUIEREMENT @ THROOP AND REARING THE BUILDING.REMEDY:REPAIR AND/OR REPLACE.
#35556029P
Sep 22, 2021
POP/IN-VIO
$0
Apr 14, 2020Construction CLASS - 2
REISSUE#35415284N.FAILURE TO MAINAIN BUILDING IN CODE-COMPLIANT MANNERAT ROOF LEVEL THE PARAPET WALL,HEIGHT IS LESS THAN THE REQUIRED HEIGHTMUST ADD A GUARDRAIL TO COMPLY WITH BUILDING CODE.REMEDY:COMPLY WITH C
#35473239J
Oct 14, 2020
POP/IN-VIO
$0
Apr 9, 2019Construction CLASS - 2
REISSUE 35253147H FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MAN NER AT ROOF THE PARAPET WALL HEIGHT LESS THAN 1 FOOT ALONG PARK AVE. RMDY: REPAIR REPLACE.
#35415284N
Aug 12, 2019
POP/IN-VIO
$0
Mar 15, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTED:AT ROOF,THE PARAPET HEIGHT IS LESS THAN 1FT ALONG AV,THROOP AVE AND REAR OF THE BLDGREM:COMPLY W/CODE.
#35325103X
Jul 16, 2018
POP/IN-VIO
$0
Apr 27, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED: AT PARAPET HEIGHT LESS THAN 1 FOOT ALONG PARK AVE, THROOP AVE AND REAR OF BUILDING .REMEDY: COMPLY WITH CODE.
#35253147H
Jun 12, 2017
POP/IN-VIO
$0
DOB (2)
IssuedViolationStatus
Jun 23, 2024FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
#00608
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#20994
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Jun 23, 2024Retro-Commissioning - LL87 FTF-EN-EARCX
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 8:44 AM ET. BBL 3017490001.