Brooklyn · Block 2102 · Lot 29 · 11205

211 Cumberland Street

4 floors · 10 apartments · 3,524 sq ft · built 1867 · class C5 · owner of record: 213 Cumberland St. Llc

46open violations
$0ECB/OATH penalties owed
9HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 59 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 59 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 75 days
Annual
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1155 days
Next cycle year 2029

Open violations

ECB / OATH (0)

None open.

DOB (5)
IssuedViolationStatus
Jan 10, 2007LANDMARK

#07-0282
DOB VIOLATION - ACTIVE
Mar 14, 2006LANDMARK

#06-0458
DOB VIOLATION - ACTIVE
Mar 31, 2004LANDMARK

#04-0674
DOB VIOLATION - ACTIVE
Aug 26, 2003LANDMARK

#04-0112
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#35587
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 2)
Active
HPD (40) · C 9 · B 24 · A 7
IssuedClassViolationCorrect by
Oct 26, 2010BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING ***MINIMUM 100 WATTS OF INCANDESCENT LIGHT REQUIRED***Nov 30, 2010
Feb 17, 2010BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINIMUM OF 100 WATTS REQUIRED.Mar 24, 2010
May 29, 2008AApt 3 · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILING 1 STY WEST APT 3 BATHROOM. LOCATED AT APT 3Sep 1, 2008
May 29, 2008AD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WROUGHT IRON FENCE NORTHWEST SIDE OF BUILDING.Sep 1, 2008
May 29, 2008BD26-10.01 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT BULGING BRICK MORTAR WALL NORTHEAST REAR SIDE OF BUILDING.Jul 3, 2008
May 29, 2008CD26-10.01 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT WOOD CORNICE ROOF NORTHEAST & WEST ER1.Jun 4, 2008
May 29, 2008CD26-10.01 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING TREAD 7 UP 1 TO 2 STY REAR ER1.Jun 4, 2008
May 29, 2008CD26-10.01 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING ROTTED TOP RETURN RAIL 2 STY BALCONY REAR ER1.Jun 4, 2008
May 29, 2008BD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS 1 STY & BASEMENT PUBLIC HALL.Jul 3, 2008
May 29, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING CELLAR THRU OUT.Jul 3, 2008
May 29, 2008CD26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW SASHES BASEMENT APT WEST ROOM.Jun 4, 2008
May 29, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL AND ON BOILER ROOM DOOR.Jun 4, 2008
May 29, 2008AD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOXES VESTIBULE 1 STY PUBLIC HALL.Sep 1, 2008
May 29, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BROWNSTONE SPALLING ALL STYS FRONT OF BLDG.Jul 3, 2008
May 29, 2008BD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE HANDRAILS STOOP FRONT OF BLDG.Jul 3, 2008
May 29, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING NEWEL POST WEST SIDE FRONT OF BLDG.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING THRU OUT WEST BASEMENT APT.Jul 3, 2008
May 29, 2008BSECTION 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING WEST BASEMENT APT.Jul 3, 2008
May 29, 2008BSECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES WEST BASEMENT APT.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BOTTOM GLASS PANE CASEMENT WINDOW BASEMENT WEST APT BATHROOM.Jul 3, 2008
May 29, 2008AD26-21.03 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALLS AT OR NEAR STAIRS ALL STYS PUBLIC HALL.Sep 1, 2008
May 29, 2008BSECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE WEST BASEMENT APT.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR BASEMENT PUBLIC HALL FRONT.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE BELL BUTTON & WIRE ENTRANCE TO BASEMENT PUBLIC HALL.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CHAIN & PADLOCK AT IRON DOOR ENTRANCE BASEMENT PUBLIC HALL.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE TREADS 4 6 7 & 8 UP FROM BOTTOM STAIRS ENTRANCE TO BLDG.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE WINDOW SILLS 2 & 3 STY BLDG FRONT.Jul 3, 2008
May 29, 2008BSECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 2 STY BALCONY REAR.Jul 3, 2008
May 29, 2008ASECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.Sep 1, 2008
May 29, 2008ASECTION 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE REAR ROOF.Sep 1, 2008
May 29, 2008ASECTION 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE STAIRS & LANDING 4 STY PUBLIC HALL.Sep 1, 2008
May 29, 2008BApt 7 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXTENSION CORD FROM 3 TY APT 7 TO 3 STY EAST APT 8. LOCATED AT APT 7Jul 3, 2008
May 29, 2008BSECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS SCUTTLE CLOSET 3 STY PUBLIC HALL.Jul 3, 2008
May 29, 2008CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED R94.Jun 4, 2008
May 29, 2008CSECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR.Jun 4, 2008
May 29, 2008CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED.Jun 4, 2008
May 29, 2008BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BRICK WALLS OBSTRUCTING WINDOW WEST BASEMENT APT BATHROOM.Jul 3, 2008
May 29, 2008BD26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THRU OUT.Jul 3, 2008
Jul 21, 2005BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PEELING SPALLING AT ALL STYS FRONT OF BLDGAug 30, 2005
Jul 21, 2005CSECTION 27-2005 ADM CODE PROVIDE TEMPORARY SECURING ALL ACCESSIBLE OPENINGS ON VACANT BLDG ER1Aug 1, 2005

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 2, 2026, 8:53 PM ET. BBL 3021020029.

Look up another building