2 floors · 2 apartments · 2,700 sq ft · built 1939 · class M9 · owner of record: Iglesia De Dios Pntcs
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Required only if the owner doesn't live there |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1139 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 3, 2009 | Construction CLASS - 1 WORK W/O A PERMIT:CELLAR CONVERTED TO MEETING ROOM WITH PARTITION CREATING TWO BATHROOMS & KITCHEN AREA WITH GAS STOVE,KITCHEN SINK AND COUNTER TOP.A SERACH OF DEPT.RECORDS SHOWN NO PERMIT ISSUED FOR SAID WORK #34805524K | Jul 19, 2011 IN VIOLATION | $0 |
| Nov 3, 2009 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT(ALLOWED) ACCORDING TO DOB RECORDS.DOB RESULTS INDICATE CELL TO USED AS STORAGE CELL NOW OCCUPIED AS MEETING ROOM WITH REREHTEUC WITH GAS STORAGE,SINK 2 BATHROOMS USED AS CLASSROOM #34805523Z | Jul 19, 2011 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 1, 2013 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT #15640 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #20722 | DOB VIOLATION - ACTIVE |
| Nov 3, 2009 | CONSTRUCTION WORK W/OUT PERMIT #ERR02 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Jan 1, 2009 | LOCAL LAW 62/91 - BOILERS #25736 | DOB VIOLATION - ACTIVE |
| Jan 3, 2008 | LOCAL LAW 62/91 - BOILERS #25844 | DOB VIOLATION - ACTIVE |
| Jun 13, 1996 | CONSTRUCTION #C13W03 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 1, 2013 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Jan 1, 2009 | Boiler LL6291 | Active |
| Jan 3, 2008 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 3, 2008 | A | SECTION 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2ND STY. FRONT AND REAR APTS. | Oct 6, 2008 |
| Jul 3, 2008 | C | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING RADIATORS 2 STY REAR APT ALL ROOMS. | Jul 9, 2008 |
| Jul 3, 2008 | A | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE -SO AS TO MAKE READILY OPENABLE- UPPER WINDOW SASH- 2 STY. FRONT APT. FRONT EAST & WEST ROOM & CENTER ROOM. | Oct 6, 2008 |
| Jul 3, 2008 | A | SECTION 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS 2 STY. FRONT APT. - ALL ROOMS. | Oct 6, 2008 |
| Jul 3, 2008 | C | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING -RADIATORS 2ND STY. REAR APT. ALL ROOMS ER1. | Jul 9, 2008 |
| Jul 3, 2008 | B | SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASH BASIN BATHROOM - 2ND STY. REAR APT. | Aug 7, 2008 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 6:30 PM ET. BBL 4105450093.