6 floors · 30,000 sq ft · built 2025 · class R0 · owner of record: Ddg 362 Ave U Owner Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 30,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 15 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 411 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 7, 2025 | Unknown CLASS - 2 MISCELLANEOUS VIOLATIONS.3314.4.4.12 PRECAUTIONS WHILE WORKING AROUND POWERLINES.OSHA 1926.451(F)(6).AT THE TIME OF INSPECTION OF A PROPOSED6 STORY NEW APARTMENT BUILDING IT WAS OBSERVED AT EXPOSURE 1 TEMPORARY #39543430Y | Dec 2, 2026 DEFAULT | $5,000 |
| Aug 7, 2025 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO HANDRAILS.AT THE TIME OF INSPECTION OF A PROPOSED 6 STORY NEW APARTMENT BUILDING UNDER CONSTRUCTION,PERMIT#B00829312-I1 IT WA #39543429R | Dec 2, 2026 DEFAULT | $6,250 |
| Jul 11, 2024 | Unknown CLASS - 1 THE WORKER FELL OFF THE CONSTRUCTION LADDER, AND THE AMBULANCE WAS CALLED. UPON REVIEW OF THE DEPARTMENT RECORDS IT WAS REVEALED THAT NO NOTIFICATION WAS MADE TO THE DEPARTMENT WITHIN 3 BUSINESS WORKING DAYS AF #39530441R | Jun 18, 2026 IN VIOLATION | $5,000 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 7:29 PM ET. BBL 3071277502.