14 floors · 154 apartments · 120,000 sq ft · built 1951 · class D3 · owner of record: Nyc Housing Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 58 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 120,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5702). Agency page | Dec 31, 2032 in 2250 days | Next due 2032 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | On file | Cycle 10 filing on record: UNSAFE (2025-12-09) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 24, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, 15-STORY BUILDING OBSERVED WITH SIDEWALK SHED NOT PROPERLY MAINTAINED. PARAPET PANELS WERE DAMAGED/MISSING AND PROTECTIVE MESH FENCING WAS INADEQUATE, ALLOWING UNAUTHORIZED ACCESS INTO TH #39557030M | Nov 6, 2026 PENDING | $2,400 |
| Apr 24, 2026 | Unknown CLASS - 1 I OBSERVED ELEVATOR INSTALLED WITHOUT AN ELECTRICAL PERMIT ON FILE. ELEVATOR ID#1P0997819 UNDER ELEVATOR APP M00836842. BIN# 1064533 .ELECTRICAL APPLICATION M00753751 IS NOT TAKING RESPONSIBILITY., OBTAIN PERMI #39186426Z | Jan 8, 2027 PENDING | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Sep 20, 2018 | FACADE SAFETY PROGRAM #HAZ87599 | DOB VIOLATION - ACTIVE |
| Sep 2, 2018 | FACADE SAFETY PROGRAM #HAZ87599 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 20, 2018 | Facades FISP CYCLE 8C UNSAFE REPORT FILED | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Closed |
| Jul 24, 2026 | ECB | Construction: AT TIME OF INSPECTION, 15-STORY BUILDING OBSERVED WITH SIDEWALK SHED NOT PROPERLY MAINTAINED. PARAPET PANELS WERE DAMAGED/MISSING AND PROTECTIVE MESH FENCING WAS INADEQUATE, ALLOWING UNAUTHORIZED ACCESS INTO TH | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)