8 floors · 42 apartments · 65,392 sq ft · built 2013 · class D1 · owner of record: 210 N 12th St Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 65,392 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 171 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 171 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 781 days | Next cycle year 2028 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $18,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 833 days | Filing window not open yet |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2291). Agency page | Dec 31, 2031 in 1876 days | Next due 2031 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 29, 2026 | Construction CLASS - 1 CEASE USE ITEM: GOVERNOR INSTALLED WITHOUT A PERMIT. NO RECORD OF APPLICATION/TEST ON FILE WITH THIS DEPARTMENT. (2.18). CLASS 2 ITEM: TOP LANDING REMOVED FROM SERVICE. #39198142P | Oct 14, 2026 DEFAULT | $2,530 |
| May 1, 2026 | Elevators CLASS - 1 1) REPAIR REGROOVE SHEAVE. 2) REPLACE HOIST ROPES. 3) PROVIDE ILLUMINATION IN ELEVATOR MR. #39186957H | Jul 8, 2026 DEFAULT | $6,250 |
| Apr 8, 2025 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C AND 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #918350. REMEDY: SUBMIT ACCEPTAB #37035172R | Apr 22, 2027 DEFAULT | $5,000 |
| Dec 2, 2020 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS RODER TO FILE A CERTIFICATE FOC ORRECTION WITH THE DEPARTMENT OF BUILDING NOTE AT TH ETIM EOF MY INSPECTION OBSERVED THAT RESPONDENT DID NOT FILE CERTIFICATE OF CORRECTI #35542478N | Nov 29, 2021 IN VIOLATION | $625 |
| Oct 15, 2020 | Construction CLASS - 2 FAILURE TO COMPLY W/ COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION W/ THE DOB. NOTE:AT THE TIME OF INSPECTION RESPONDENT DID NOT COMPLY W/ PREVIOUS VIO#35466593R ISSUED ON 8-6-2020. AS OF DATE OF INS #35537964M | Apr 8, 2022 IN VIOLATION | $625 |
| Aug 6, 2020 | Construction CLASS - 1 FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.NOTE:AT PRESENT TIME NO ACCEPTABLE STRUCTURAL STABILITY EVALUATION REPORT OF BLDG FACADE WAS SUBMITTED TO DOB AS DIRECTED IN THE COMMISSIONER'S ORDER NUMBER. #35466592P | Mar 21, 2022 IN VIOLATION | $12,500 |
| Aug 6, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BLDG FACADE & APPURTENANCES.NOTE:ON 08/03/2020 AN STUCCO(EIFS)EXTERIOR INSULATION & FINISH SYSTEM WAS DISLODGED& FELL ONTO ADJOINING ROOF FROM 7TH FL LEVEL APPROX. 20'X20' AREA AT #35466593R | Nov 15, 2021 IN VIOLATION | $12,500 |
| Apr 30, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BLDG FACADE & APPURTENANCES.NOTE:AT THE TIME OF INSPECTION(FACADE) OBSERVE SECTION OF DEFECTS & IMMINENT HAZARDOUS CONDITION WERE OBSERVE:1)EXPOSURE#2{DRIGGS AVE} AT 7TH FL TERRACE #35466585R | Nov 15, 2021 IN VIOLATION | $12,500 |
| Mar 1, 2018 | Elevators CLASS - 1 05X10,100M07. 05X10-REPAIR DOOR ZONE RESTRICTOR; 100M07-PROVIDE ELEVATOR SERVICING COMPANY INFO DATA ON MAIN DISCONNECT BOX. #38261875P | Aug 20, 2018 IN VIOLATION | $1,000 |
| Issued | Violation | Status |
|---|---|---|
| Jun 23, 2024 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) #00193 | DOB VIOLATION - ACTIVE |
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #01265 | DOB VIOLATION - ACTIVE |
| Apr 22, 2023 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) #01123 | DOB VIOLATION - ACTIVE |
| Aug 21, 2022 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2021 #10323 | DOB VIOLATION - ACTIVE |
| Feb 3, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00060 | DOB VIOLATION - ACTIVE |
| Nov 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00072 | DOB VIOLATION - ACTIVE |
| Aug 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00378 | DOB VIOLATION - ACTIVE |
| May 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00564 | DOB VIOLATION - ACTIVE |
| Feb 17, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00159 | DOB VIOLATION - ACTIVE |
| Feb 2, 2018 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00226 | DOB VIOLATION - ACTIVE |
| Nov 2, 2017 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00271 | DOB VIOLATION - ACTIVE |
| Aug 2, 2017 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00345 | DOB VIOLATION - ACTIVE |
| May 2, 2017 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00696 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 23, 2026 | Parking Structures FTF-PS-INITL Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Feb 3, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Feb 17, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Feb 2, 2018 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 2, 2017 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 2, 2017 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 2, 2017 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 23, 2026 | DOB Safety | Parking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Open |
| Jul 29, 2026 | ECB | Elevators: MISSING IN CASE OF FIRE SIGN IN LOBBY (BC 3002.3). REPLACE WORN GIBS WHERE NEEDED (2.11.11.5.7.). TOP LANDING IS AN ILLEGAL VESTIBULE (2.11.6.5.). UNGUARDED MACHINE ROOM EQUIPMENT (8.6.4.1.). REMOVE ALL DEBRIS | Closed |
| Jul 29, 2026 | ECB | Construction: CEASE USE ITEM: GOVERNOR INSTALLED WITHOUT A PERMIT. NO RECORD OF APPLICATION/TEST ON FILE WITH THIS DEPARTMENT. (2.18). CLASS 2 ITEM: TOP LANDING REMOVED FROM SERVICE. | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 10:12 AM ET. BBL 3022910017.