12 floors · 165,875 sq ft · built 1910 · class O6 · owner of record: 120 E 16 St Co Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 165,875 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $202,500 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 850 days | Filing window not open yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 871). Agency page | Dec 31, 2031 in 1893 days | Next due 2031 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-19 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 30, 2005 | Boilers Non-Hazardous B4A/ 50/ 50A/ 50B/ 50C/ 50D/ (50) HOLES IN BOILER ROOM WALLS. (50A) PROVING SWITCH FOR FRESH AIR FAN DEFECTIVE (50B) BOILER SAFTY VALVE NOT PIPED DOWN. (50C) MAN HOLE CORRODED AND BOILER INSOLATOR JACKET CORROD #32048799L | Mar 8, 2007 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) CYCLE 9 FAILURE TO CORRECT SWARMP CONDITIONS #00012 | DOB VIOLATION - ACTIVE |
| Feb 19, 2025 | HAZARDOUS CONDITION (FACADE) CYCLE 9C UNSAFE REPORT FILED #912034 | DOB VIOLATION - ACTIVE |
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #00158 | DOB VIOLATION - ACTIVE |
| May 21, 2013 | ELEVATOR #9028/442920 | DOB VIOLATION - ACTIVE |
| May 20, 2013 | ELEVATOR #9028/442921 | DOB VIOLATION - ACTIVE |
| May 20, 2013 | ELEVATOR #9028/442920 | DOB VIOLATION - ACTIVE |
| Apr 4, 2001 | ELEVATOR 1P3528 #1P3528 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR #1147B-3 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR 51-RESTORE SIDEWALK ELEVATOR 2463 TO PROPER SERVICE SO INSPECTION CAN BE MADE BY A MEMBER OF THIS DEPARTMENT #1147B/7 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR #1147B-4 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR #1147B-6 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR #1147B-8 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR #1147B/1 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR #1147B/2 | DOB VIOLATION - ACTIVE |
| Nov 9, 1988 | ELEVATOR 51-FILE BUILDING NOTICE TO OBTAIN PERMIT FOR REMOVEL ELEVATOR #1147B/5 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| May 7, 2025 | Facades FISPFCS CYCLE 9 FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Feb 19, 2025 | Facades FISPHAZ CYCLE 9C UNSAFE REPORT FILED | Active |
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)