6 floors · 42 apartments · 27,600 sq ft · built 1900 · class C1 · owner of record: Sloyer-Furman Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 27,600 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 778 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-14 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 5, 2025 | Construction CLASS - 1 ATOI AT ABOVE PREMISES IN UNITS #1 AND #2 FIRE RATING HAS BEEN REMOVED FROM THE ENTIRE UNITS. UNITS #4 AND #5 REMAINS OCCUPIED AND ONGOING CONSTRUCTION AND NO FIRE GUARD PRESENT., PROVIDE/MAINTAIN FIRE STOPPING #39156040Z | Dec 21, 2026 DEFAULT | $6,250 |
| Aug 5, 2025 | Unknown CLASS - 2 ATOI OBSERVED IN UNITS 1 AND 2 WORK NOT IN COMPLIANCE WITH THE TPP SUBMITTED. FIRE RATING HAS BEEN FULLY REMOVED, WHILE THE UNITS ABOVE REMAINS OCCUPIED. THE TPP DOES NOT INDICATED THAT A FIRE GUARD WOULD BE PR #39156022P | Dec 21, 2026 DEFAULT | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| Feb 15, 2012 | CONSTRUCTION #0301RJ | DOB VIOLATION - ACTIVE |
| Feb 15, 2012 | CONSTRUCTION #ER0301RJ | DOB VIOLATION - ACTIVE |
| Feb 15, 2012 | CONSTRUCTION MATTERS NOT PROVIDED #NE01LA | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 14, 2023 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCK DOOR AT BOILER ROOM | Aug 20, 2023 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)