Queens · Block 857 · Lot 25 · 11105

21-19 27 Street

4 floors · 16 apartments · 11,000 sq ft · built 1927 · class C1 · owner of record: 21-19 27 Street Realty Llc

35open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
60dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 60 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 76 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 791 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-17 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (1)
IssuedViolationStatus
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#17848
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
HPD (33) · C 3 · B 29 · A 1
IssuedClassViolationCorrect by
Jun 30, 2022B§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING DROP LADDER AT REAR FIRE ESCAPE AT FIRE ESCAPEAug 4, 2022
Jun 3, 2021CApt C2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT C2, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJun 29, 2021
Jun 3, 2021BApt C2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEVICE DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT C2, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJul 8, 2021
Jun 3, 2021BApt C2 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEVICE DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT C2, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJul 8, 2021
May 29, 2008AApt 4D · D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS CLG TRIM FRONT ROOM KITCHEN BATHROOM 4 STY EAST APT 4D. LOCATED AT APT 4DSep 1, 2008
May 29, 2008BApt C1 · D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALL SOUTH BATHROOM 3 STY WEST APT C1. LOCATED AT APT C1Jul 3, 2008
May 29, 2008BD26-10.01 ADM CODE PROVIDE ELECTRICAL BOX COVER OVER OIL TANK CELLAR.Jul 3, 2008
May 29, 2008BApt D2 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 4 STY APT D2 TENANT DAPONTES. LOCATED AT APT D2Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRING THROUGH NORTH WALL OF BOILER ROOM CELLAR.Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEET ROCK & METAL FIRE RETARDED CEILING BOILER ROOM CELLAR.Jul 3, 2008
May 29, 2008BApt B3 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRING WALLS FRONT ROOM 2 STY APT B3. LOCATED AT APT B3Jul 3, 2008
May 29, 2008BApt C1 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WASHBASIN BATHROOM 3 STY APT C1. LOCATED AT APT C1Jul 3, 2008
May 29, 2008BApt C1 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY APT C1 TENANT LEBOS. LOCATED AT APT C1Jul 3, 2008
May 29, 2008BApt C3 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY APT C3. , SECTION '' ''Jul 3, 2008
May 29, 2008BApt D3 · SECTION 27-2026 ADM CODE REPAIR BY CLOSING SO AS TO BE GAS TIGHT ALL OPENINGS IN THE KITCHEN SINK WASTE PIPE 4 STY APT D3. LOCATED AT APT D3Jul 3, 2008
May 29, 2008BApt D3 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & WALLS 4 STY APT D3 REAR ROOM. LOCATED AT APT D3Jul 3, 2008
May 29, 2008BApt D3 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 4 STY APT D3 TENANT MS MANILLO. LOCATED AT APT D3Jul 3, 2008
May 29, 2008BApt D3 · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT ENTRANCE TO 4 STY APT D3. LOCATED AT APT D3Jul 3, 2008
May 29, 2008BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER WALLS PUB HALL BULKHEAD.Jul 3, 2008
May 29, 2008BApt B3 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 2 STY APT B3 TENANT ZANFAKYRES. LOCATED AT APT B3Jul 3, 2008
May 29, 2008BApt D2 · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DUMBWAITER DOOR SEALED CLOSED 4 STY APT D2. , SECTION '' ''Jul 3, 2008
May 29, 2008BD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR LOCK ASSEMBLY VESTIBULE TO 1 STY PUB HALL R202.Jul 3, 2008
May 29, 2008BApt C3 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG BATHROOM 3 STY NORTHEAST APT C3. LOCATED AT APT C3Jul 3, 2008
May 29, 2008BApt C3 · D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC WALL TILE WEST WALL BATHROOM 3 STY NORTHEAST APT C3. LOCATED AT APT C3Jul 3, 2008
Apr 8, 2004BApt A4 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE. IN THE ENTIRE APARTMENT LOCATED AT APT A4, 1st STORY, APARTMENT AT EASTMay 18, 2004
Apr 8, 2004BApt A4 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT A4, 1st STORY, APARTMENT AT EASTMay 18, 2004
Feb 20, 1996CSECTION 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM TO BECOME INOPERABLE CONSISTING OF DAY THERMOSTAT DIAL SET BELOW 55 DEGREES AT HEAT TIMER AT CELLAR.Mar 12, 1996
Feb 20, 1996CSECTION 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM TO BECOME INOPERABLE CONSISTING OF NIGHT THERMOSTAT DIAL SET BELOW 40 DEGREES AT HEAT TIMER AT CELLAR.Mar 12, 1996
Apr 2, 1991BSECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FIRE PROOF SELF CLOSING DOOR PUB HALL BULKHEAD TO ROOF.May 20, 1991
Apr 2, 1991BApt D3 · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASH BASIN BATHROOM 4 STY APT D3. LOCATED AT APT D3May 20, 1991
Apr 2, 1991BSECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SASH CHAIN 3 TO 4 STY PUB HALL STAIRS WINDOW.May 20, 1991
Apr 2, 1991BSECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES REAR STACK ALL STY.May 20, 1991
Apr 2, 1991BApt D3 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR TO BATHROOM 4 STY APT D3. LOCATED AT APT D3May 20, 1991

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 10:41 AM ET. BBL 4008570025.