2 floors · 2,976 sq ft · built 2024 · class K4 · owner of record: 21-02 Usa, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1158 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 19, 2025 | Unknown CLASS - 2 @NB SITES(21-08/06/04/02 COLLEGE POINT BLVD)WITH SAME SUPER ON PERMITS OBSERVE SUPER FAILED TO PERFORM DUTIES-NONE OF THE LOGS NOTE ANY UNSAFE+CORRECTIVE ACTIONS&DEPARTMENTS VIOS+STOP WORK ORDER+APPARENT SITE V #39538163M | Mar 22, 2027 | $5,000 |
| Mar 19, 2025 | Construction CLASS - 1 @ACTIVE SITE OBSERVE NO CONTAINER, EQUIPMENT-MATERIAL-DEBRIS OBSTRUCTING EGRESS PATHWAYS IN&OUT OF SITES, UNSECURED ELEVATED MATERIAL SUSCEPTIBLE TO DISLODGMENT, ACCUMULATED COMBUSTIBLE DEBRIS(LUMBER) STORED WI #39538164Y | Sep 28, 2026 IN VIOLATION | $1,250 |
| Mar 5, 2025 | Unknown CLASS - 2 OBSERVED WORK BEING PERFORM ON SUPPORTED SCAFFOLD AT EXPOSURE #1. THE SCAFFOLD PLATFORM WAS NOT FULLY PLANK, TOE BOARDS AND GUARDRAILS WERE NOT INSTALLED. IN ADDITION, THERE WERE MIXED FRAMES OBSERVED. ALSO, TH #39537639Y | Feb 23, 2027 | $2,500 |
| Feb 17, 2025 | Unknown CLASS - 2 OBSERVED NO WINDOW PROTECTION & NO OVER HEAD PROTECTION PROVIDED TO WALK WAY OF ADJACENT PROPERTY @ EXPOSURE 2 OF JOBSITE. STOP ALL EXTERIOR WORK @ EXPOSURE 2 & 10 FT FROM PROVIDE/MAINTAIN ADEQUATE PROTECTION F #39537035N | Oct 9, 2025 IN VIOLATION | $2,500 |
| Oct 25, 2024 | Unknown CLASS - 1 3309.1-OBSERVED CMU BLOCKS BEING INSTALLED & CONSTRUCTION OPERATIONS ABOVE ADJACENT PROPERTY MISSING OVERHEAD PROTECTION @ 2 & 3. LACK OF PROTECTION CREATES HAZARDOUS CONDITIONS FOR RESIDENTS & PROTECTION OF T #39533812K | Jul 24, 2026 IN VIOLATION | $2,500 |
| Oct 25, 2024 | Construction CLASS - 1 3301.1.1-OBSERVED CONSTRUCTION OPERATIONS @ MULTIPLE LOCATIONS, EDGES, OPEN HOLES, WORKERS NOT PROPERLY TIED OFF, WORKING ON EDGE OF OPEN HOLES W/ REBARS DOWELS @ EDGE APPROX. 3 FEET IN HEIGHT, NO GUARDRAILS AN #39533813M | Jul 24, 2026 IN VIOLATION | $625 |
| Oct 25, 2024 | Unknown CLASS - 1 3305.3.5.2-OBSERVED CONSTRUCTION OPERATIONS USE OF A CONCRETE MIXER, MULTIPLE PALLETS OF CONCRETE STORED & CMU BLOCKS STORED ON AN UNPOURED QDECK.STORAGE OF LIVE LOADS/ DEAD LOADS CAN CREATE A DEFLECTION OF QDE #39533814Y | Jan 15, 2027 | $5,030 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)