Bronx · Block 3149 · Lot 111 · 10457

2085 Valentine Avenue

6 floors · 78 apartments · 72,666 sq ft · built 1929 · class D7 · owner of record: 2085 Valentine Llc D

82open violations
$53,125ECB/OATH penalties owed
10HPD class C (immediately hazardous)
50dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 50 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 66 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 72,666 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 171 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 171 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 294 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1146 days
Next cycle year 2029
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3149). Agency page

Dec 31, 2029
in 1146 days
Next due 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-21 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (17) · $53,125 owed
IssuedViolationHearingBalance
Nov 4, 2026Elevators CLASS - 2
CLASS2 ITEMS: PHONE INOPERATIVE ASME A17.1-2013 SECTION 2.27.1.1 EMERGENCY COMMUNICATIONS REQUIRES, 2-ELEVATOR NOT LEVEL WITH LANDING FLOOR 2.26.1.6 - LEVELING ZONE OPERATION AJUST.
#39210495J
Jan 15, 2027
PENDING
$625
Oct 30, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, NO ACCESS WAS GAINED TO THE PREMISES, AND NO CERTIFICATE OF CORRECTIO
#39210139N
Jan 15, 2027
PENDING
$1,250
Oct 30, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIMES OF INSPECTION, NO ACCESS WAS GAINED TO THE PREMISES, AND NO CERTIFICATE OF CORRECTI
#39210137J
Jan 15, 2027
PENDING
$1,250
Oct 30, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIMES OF INSPECTION, NO ACCESS WAS GAINED TO THE PREMISES, AND NO CERTIFICATE OF CORRECTI
#39210141M
Jan 15, 2027
PENDING
$1,250
Oct 30, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED THAT THE VIOLATING CONDITION HAD BEEN CORRECTED UNDER PERMIT
#39210138L
Jan 15, 2027
PENDING
$1,250
Oct 30, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, DOB RECORDS INDICATE WORK WAS PERMITTED UNDER PERMIT #X01294794-I1-EL
#39210142Y
Jan 15, 2027
PENDING
$1,250
Oct 30, 2026Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. AT TIME OF INSPECTION, OBSERVED EXCESSIVE CONSTRUCTION MATERIALS, DEBRIS, APPLIANCES, AND A MAKESHIFT SHANTY CONSTRUCTED OF 2X4 LUMBER OBSTRUCTING THE BASEMENT PASSAGE
#39210140K
Jan 15, 2027
PENDING
$6,250
Sep 28, 2026Elevators CLASS - 2
ELEVATOR MACHINE ROOM/EMR OVERHEAD DOOR IS DAMAGED AND FOUND OPEN, WITH DEBRIS OBSERVED INSIDE THE OVERHEAD LOCK. DOOR/LOCK SHALL BE REPAIRED AND SECURED TO PREVENT UNAUTHORIZED ACCESS. ASME A17.1-2013 2.7.3. E
#39205838X
Dec 4, 2026
ADMIT/IN-VIO
$0
Nov 14, 2025Elevators CLASS - 1
CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. ELEVATOR DIVISION AT FOR A REINSPEC
#39167001J
Jan 30, 2026
ADMIT/IN-VIO
$0
Jul 10, 2024Construction CLASS - 2
I OBSERVED IN APTS 1F, 1H, 4F,4G,4H,4J THE REMOVAL OF THE PLUMBING FIXTURES UP TO AND INCLUDING THE SANITARY LINES AS WELL AS THE WATERLINES TO NEW FIXTURES, NO PERMIT IN DOB RECORDS COVERS THE SCOPE OF WORK PE
#39118891J
Sep 20, 2024
ADMIT/IN-VIO
$0
Jul 10, 2024Construction CLASS - 1
I OBSERVED IN THE BASEMENT AREA FROM THE BASEMENT DOOR ON VALENTINE AVE TO THE SECOND EXIT DOOR EXCESSIVE CONSTRUCTION MATERIAL , DEBRIS AND APPLIANCES ALONG THE PASSAGEWAY. THIS IS AN IMMEDIATE FIRE AND SAFETY
#39118888Z
Nov 25, 2025
IN VIOLATION
$0
Jul 10, 2024Unknown CLASS - 1
I OBSERVED IN APTS 1F, 1H,4H,4J 4F,4G, THE INSTALLATION OF A NEW CIRCUIT BREAKER PANEL AND BRANCH CIRCUIT WIRING THROUGHOUT THE APARTMENT, NO PERMIT ON FILE IN DOB RECORDS COVERS THIS WORK. STOP ALL ELECTRICAL
#39118886P
Nov 25, 2025
IN VIOLATION
$0
Sep 18, 2023Unknown CLASS - 2
AT TIME OF INSPECTION ,OBSERVED NEWLY CONSTRUCTED ROOM IN BASEMENT ,BLOCKING ELECTRICAL METERS ,AND NOT MAINTAINING A 3 FOOT SPACE BETWEEN METERS AND NEWLY CONSTRUCTED ROOM ., PROVIDE/MAINTAIN ACCESS/WORK SPACE
#39095133L
Jul 8, 2025
DEFAULT
$2,500
Sep 18, 2023Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED IMPROPER /UNSAFE STORAGE OF COMBUSTIBLE MACHINE/MATERIAL AND EQUIPMENT (GAS SNOW BLOWER)STORE IN COMMON AREA (WALK WAY) OF BASEMENT ., MAINTAIN STORAGE IN COMPLIANCE WITH FIRE COD
#39095135P
Dec 1, 2023
DEFAULT
$12,500
Sep 18, 2023Construction CLASS - 1
AT TIME OF INSPECTION ,OBSERVED EXCESSIVE STORAGE CONSTRUCTION COMBUSTIBLE MATERIALS ALONG THE HALL WAY OF BASEMENT COMMAN AREA ,POOR HOUSEKEEPING IMMIDATE DANGER TO PROPERTY ,TENANTS AND INCASE OF AN EMERGANCE
#39095134N
Dec 1, 2023
DEFAULT
$12,500
Sep 18, 2023Construction CLASS - 1
AT TIME OF INSPECTION,OBSERVED EXCESSIVE STORAGE OF CONSTRUCTION COMBUSTIBLE GARBAGE STORED IN APT 4H AND 4 J ON THE 4 FLOOR OF BUILDING, MAINTAIN ADEQUATE CONSTRUCTION HOUSEKEEPING
#39095131H
Dec 1, 2023
DEFAULT
$12,500
Apr 30, 2023Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING WALL AND APPURTENANCE - APPROX. 100' OUT OF 150' OF THE RETAINING WALL COLLAPSED INTO THE REAR YARD CAUSING EXTERIOR WALL BLOW OF APARTMENT 1F AND INTERIOR DAMAGES TO 1H. THE REMAIN
#39085038Y
Feb 27, 2024
ADMIT/IN-VIO
$0
DOB (13)
IssuedViolationStatus
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00395
DOB VIOLATION - ACTIVE
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00394
DOB VIOLATION - ACTIVE
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00393
DOB VIOLATION - ACTIVE
Apr 3, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00088
DOB VIOLATION - ACTIVE
Jan 3, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00051
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01156
DOB VIOLATION - ACTIVE
Feb 3, 2023FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00030
DOB VIOLATION - ACTIVE
Nov 3, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00042
DOB VIOLATION - ACTIVE
Aug 3, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00096
DOB VIOLATION - ACTIVE
Jun 2, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00282
DOB VIOLATION - ACTIVE
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#03813
DOB VIOLATION - ACTIVE
May 31, 2018NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
#00446
DOB VIOLATION - ACTIVE
Jan 7, 2006ELEVATOR

#9444/153826
DOB VIOLATION - ACTIVE
DOB NOW Safety (15)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Jul 24, 2024AEUHAZ FTC-AEU-HAZ
Active
Jun 12, 2024AEUHAZ FTC-AEU-HAZ
Active
Apr 3, 2024AEUHAZ FTC-AEU-HAZ
Active
Jan 3, 2024AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Feb 3, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 3, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 3, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 2, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Sep 6, 2019Elevators ACC1
Active
May 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
Active
HPD (37) · C 10 · B 20 · A 7
IssuedClassViolationCorrect by
Sep 8, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD LESS THAN 10 SQ FEET AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' ORIGINAL VIOLATION 18908767 ISSUED 09-MAY-26 HAS BEEN UPGRADED TO CLASS B PEOct 13, 2026
Sep 4, 2026C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF STORE FRONT [GOMEZ TAX SERVICE] GATE SLEEVE IMPENDING DOWNWARD MOTION TO DROP LADDER AT 2ND FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL (BUILDING FRONT)Sep 10, 2026
Sep 4, 2026A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER [AND PROPERLY SECURE BY USING APPROPIATE NUTS AND BOLTS] AT 1ST FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL (BUILDING FRONT) AT FIRE ESCAPEDec 8, 2026
Sep 4, 2026C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GARBAGE BINS OBSTRUCTING DOWNWARD MOTION TO DROP LADDER AT 1ST FIRE ESCAPE FROM EAST AT NORTH EXTERIOR WALL (TRASH AREA AT BUILDING FRONT)Sep 10, 2026
Aug 11, 2026AApt 2F · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''south''Nov 14, 2026
Jul 2, 2026CApt 2F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''south''Jul 28, 2026
Jul 2, 2026AApt 2F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''south''Oct 5, 2026
Jul 2, 2026CApt 2F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH GLASS PANE AT THE 2ND WINDOW FROM SOUTH AT WEST IN THE 4th ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''south''Jul 8, 2026
Jul 2, 2026CApt 2F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''south''Jul 28, 2026
Jun 8, 2026BApt 6M · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES : WASH BASIN IN THE BATHROOM LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHJul 13, 2026
Jun 8, 2026BApt 6M · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BY METHOD OF PORCELIN ENAMEL FINISH AT BATH TUB IN THE BATHROOM LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHJul 13, 2026
Jun 8, 2026BApt 6M · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES : WASH BASIN IN THE BATHROOM LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHJul 13, 2026
May 19, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD GREATER THAN 10 SQ FEET AT CEILING ,EAST AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 23, 2026
May 19, 2026BApt 6E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 23, 2026
May 18, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT CEILING AND NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 22, 2026
May 18, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT CEILING, EAST NORTH AND SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 22, 2026
May 18, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD GREATER THAN 10 SQ FT AT THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 22, 2026
May 11, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD LESS THAN 20 SQ FEET AT CEILING AND ALL WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 15, 2026
May 11, 2026BApt 6E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BROKE TILE FLOOR IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 15, 2026
May 11, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD LESS THAN 20SQ FEET AT ALL WALL AND CEILNG IN THE 2nd ROOM FROM EAST LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 15, 2026
May 11, 2026BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD MORE THAN 10 SQ FEET AT THE CEILING AND ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jun 15, 2026
May 6, 2026CApt 3G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJun 1, 2026
May 6, 2026CApt 3G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJun 1, 2026
Apr 9, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAJul 13, 2026
Oct 29, 2025CApt 2G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''Nov 24, 2025
Oct 29, 2025BApt 3G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTDec 3, 2025
Oct 29, 2025BApt 3G · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTDec 3, 2025
Oct 29, 2025BApt 3G · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3G, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTDec 3, 2025
Oct 29, 2025BApt 3G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS AND CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3G, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTDec 3, 2025
Oct 29, 2025CApt 3G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTNov 24, 2025
Oct 29, 2025CApt 3G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTNov 24, 2025
Oct 29, 2025BApt 2G · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING KNOB AT RADIATOR SHUT OFF VALVE IN THE 2nd ROOM FROM EAST LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''Dec 3, 2025
Oct 29, 2025BApt 2G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE TOP ESCUTCHEON PLATE AT HEAT RISER IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''Dec 3, 2025
Feb 4, 2025BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT WEST WALL IN THE FOYER LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' ORIGINAL VIOLATION 17325449 ISSUED 04-OCT-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRMar 11, 2025
Sep 17, 2024A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL PARTS AND COMPONENTS AT ALL STORIES AT 1ST, 2ND AND 3RD FIRE ESCAPE, BUILDING FRONTDec 21, 2024
Sep 17, 2024A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL PARTS AND COMPONENTS AT ALL STORIES AT 1ST FIRE ESCAPE FROM WEST AT SOUTHDec 21, 2024
Sep 6, 2011AApt 1A · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD WALL PANELING IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHDec 10, 2011

Issued in the last 120 days

DateSourceWhatNow
Nov 4, 2026ECBElevators: CLASS2 ITEMS: PHONE INOPERATIVE ASME A17.1-2013 SECTION 2.27.1.1 EMERGENCY COMMUNICATIONS REQUIRES, 2-ELEVATOR NOT LEVEL WITH LANDING FLOOR 2.26.1.6 - LEVELING ZONE OPERATION AJUST.Open
Oct 30, 2026ECBConstruction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, NO ACCESS WAS GAINED TO THE PREMISES, AND NO CERTIFICATE OF CORRECTIOOpen
Oct 30, 2026ECBConstruction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIMES OF INSPECTION, NO ACCESS WAS GAINED TO THE PREMISES, AND NO CERTIFICATE OF CORRECTIOpen
Oct 30, 2026ECBConstruction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIMES OF INSPECTION, NO ACCESS WAS GAINED TO THE PREMISES, AND NO CERTIFICATE OF CORRECTIOpen
Oct 30, 2026ECBConstruction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED THAT THE VIOLATING CONDITION HAD BEEN CORRECTED UNDER PERMITOpen
Oct 30, 2026ECBConstruction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, DOB RECORDS INDICATE WORK WAS PERMITTED UNDER PERMIT #X01294794-I1-ELOpen
Oct 30, 2026ECBConstruction: FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. AT TIME OF INSPECTION, OBSERVED EXCESSIVE CONSTRUCTION MATERIALS, DEBRIS, APPLIANCES, AND A MAKESHIFT SHANTY CONSTRUCTED OF 2X4 LUMBER OBSTRUCTING THE BASEMENT PASSAGEOpen
Sep 28, 2026ECBElevators: ELEVATOR MACHINE ROOM/EMR OVERHEAD DOOR IS DAMAGED AND FOUND OPEN, WITH DEBRIS OBSERVED INSIDE THE OVERHEAD LOCK. DOOR/LOCK SHALL BE REPAIRED AND SECURED TO PREVENT UNAUTHORIZED ACCESS. ASME A17.1-2013 2.7.3. EOpen
Sep 8, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD LESS THAN 10 SQ FEET AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' ORIGINAL VIOLATION 18908767 ISSUED 09-MAY-26 HAS BEEN UPGRADED TO CLASS B PEOpen
Sep 4, 2026HPD C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF STORE FRONT [GOMEZ TAX SERVICE] GATE SLEEVE IMPENDING DOWNWARD MOTION TO DROP LADDER AT 2ND FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL (BUILDING FRONT)Open
Sep 4, 2026HPD A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER [AND PROPERLY SECURE BY USING APPROPIATE NUTS AND BOLTS] AT 1ST FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL (BUILDING FRONT) AT FIRE ESCAPEOpen
Sep 4, 2026HPD C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GARBAGE BINS OBSTRUCTING DOWNWARD MOTION TO DROP LADDER AT 1ST FIRE ESCAPE FROM EAST AT NORTH EXTERIOR WALL (TRASH AREA AT BUILDING FRONT)Open
Aug 11, 2026HPD A§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''south''Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 5:25 PM ET. BBL 2031490111.

Look up another building