Manhattan · Block 440 · Lot 6 · 10009

208 1 Avenue

4 floors · 5 apartments · 3,945 sq ft · built 1900 · class S5 · owner of record: 208 First Ave Llc

15open violations
$3,750ECB/OATH penalties owed
1HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 60 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 76 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 791 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-07 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7) · $3,750 owed
IssuedViolationHearingBalance
Oct 30, 2024Boilers CLASS - 2
FOUND PEERLESS ( MODEL#ECT 05) OIL FIRED BOILER IN CELLAR NOT REGISTERED CORRECT VIOLATING CONDITION SUBHMIT CERTIFICATE OF CORRECTION
#39128918J
Jan 9, 2025
IN VIOLATION
$0
Aug 24, 2021Boilers CLASS - 2
NEED COMBUSTION AIR FROM OUTSIDE TO DIRECTLY TO THE BOILER ROOM,SEAL LOUVER ON BOILER ROOM DOOR,COVER EXPOSED OIL LINES IN BOILER ROOM,NEED COVER ON OPEN ELECTRICAL BOX ,EXPOSED WIRES CORRECT VIOLATIONS AND SEN
#39046495H
Mar 10, 2022
DEFAULT
$3,125
Jun 3, 2021Construction CLASS - 1
AN UNLAWFUL ACT FAILURE TO COMPY WITH AN ORDER FO THE COMMISSIONERS FAILURE TO CORRECT AND CERTIFY SUMMONS #35547887R WHICH WAS ISSUED ON 04-22-2021 FOR YOU DOING ELECTRICAL WORK WITHOUT A PERMIT YOU ALSO
#35548053P
Oct 14, 2021
IN VIOLATION
$0
Apr 22, 2021Unknown CLASS - 2
FAILURE TO INSTALL GROUND FAULT CIRCUIT INTERRUPTER GFCI PROTECTION ASREQUIRED.NO GFCI FOR PLUG IN OUTDOOR LIGHTING IN EATING FACILITY.INSTALL GFCI PROTECTION.
#35547889K
Oct 14, 2021
IN VIOLATION
$0
Apr 22, 2021Unknown CLASS - 1
UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICE APPARATUS APPLIANCES MATERIALS OR WIRING IN USE DEFECTIVE&EXPOSED ELECTRICAL WIRING@OUTDOOR EATING FACILITY.COMPLY W/EC CODE.
#35547888Z
Oct 14, 2021
IN VIOLATION
$0
Apr 22, 2021Unknown CLASS - 1
ELECTRICAL WORK W/O PERMIT OBSERVED@140PM TEMP WIRING FROM BSMT TO OUTDOOR EATING FACILITY NOT FLEXIBLE CORD TEMP WIRING NO APP ON FILE FOR ELECTRICAL WORK FROM BSMT.OBTAIN PERMIT.
#35547887R
Oct 14, 2021
IN VIOLATION
$0
Sep 9, 2019Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED, AT THE TIME OF INSPECTION OBSERVED THE VENTILATION FANS LOCATED ON THE LOWER ROOF IN 2ND FLOOR IN FRONT OF 2ND AND 3RD FLOOR APARTMENTS WITHOUT CHIM
#39009127L
Jun 18, 2020
IN VIOLATION
$625
DOB (4)
IssuedViolationStatus
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#02092
DOB VIOLATION - ACTIVE
Oct 8, 1991CONSTRUCTION

#STN03
DOB VIOLATION - ACTIVE
Apr 26, 1990ELECTRIC SIGNS

#STA1M
DOB VIOLATION - ACTIVE
Aug 12, 1988CONSTRUCTION

#A4H02
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
HPD (2) · C 1 · B 1 · A 0
IssuedClassViolationCorrect by
Jun 12, 2025CApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 10 SQ FT AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16279213 ISSUED 03-OCT-23 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.Jul 8, 2025
Jun 11, 2025BApt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE BATHROOM LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 16, 2025

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 3:31 AM ET. BBL 1004400006.