| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 23, 2026 | Construction CLASS - 2 THE RESPONDENT HAS FAILED TO COMPLY WITH THE COMMISSIONER'S ORDER AND TO FILE A CERTIFICATION OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR A CLASS I VIOLATION ISSUED ON 02/20/2026. REF ECB: 39550649Y.FILE #39560988H | Jan 15, 2027 PENDING | $1,250 |
| Aug 19, 2026 | Construction CLASS - 2 GENERAL CONTRACTOR FAILED TO FILE CERTIFICATE OF CORRECTION WITH THE DOB. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION# 039550649Y-ISSUED 2-20-2026... #39558142L | Jan 22, 2027 PENDING | $1,250 |
| Jun 23, 2026 | Construction CLASS - 2 DURING INSPECTION OF A CLOSED 4-STORY NB, AND UPON REVIEWING THE DOB SYSTEM, IT WAS REVEALED THAT THE PERMIT HOLDER HAD FAILED TO COMPLY WITH THE COMMISSIONER'S ORDER AND TIMELY PROVIDE A CERTIFICATE OF CORRECT #39555805J | Mar 19, 2027 PENDING | $1,250 |
| Apr 16, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF A CLOSED PROPOSED 4-STORY NB. UPON REVIEWING THE DOB SYSTEM, IT WAS REVEALED. THAT THE PERMIT HOLDER FAILED TO TIMELY PROVIDE A CERTIFICATION OF CORRECTION FOR CLASS ONE VIOLATIO #39553115N | Nov 20, 2026 PENDING | $1,250 |
| Feb 20, 2026 | Unknown CLASS - 2 GC 626425-ON ACTIVE JOBSITE, OBSERVED MULTIPLE FIRE EXTINGUISHERS INADEQUATE TO THE FIRE. THE FIRE EXTINGUISHERS ARE ALL MISSING FDNY INSPECTION TAGS. STOP ALL WORK UNDER APPLICATIONCOMPLY WITH FIRE CODE, PROVI #39550651N | Mar 5, 2027 | $625 |
| Feb 20, 2026 | Unknown CLASS - 2 GC 626425-(3307.6.4.4 VERTICAL MEMBERS AND BEAMS)- OBSERVED SIDEWALK SHED OVER DRIVEWAY OF ADJACENT PROPERTY @ EXPOSURE 2. THE VERTICAL MEMBERS OF SHED IS NOT ANCHORED INTO GROUND AND NO HIGH VISIBILITY MARKING #39550653R | Apr 9, 2027 | $2,500 |
| Feb 20, 2026 | Construction CLASS - 1 GC-626425 OBSERVED FLOOR FRAMING CONSISTING OF COLD FORM STEEL AND DRAGON BOARD. UPON REVIEW OF PROVIDED APPROVED DRAWINGS IT SHOWS FLOORS IS TO METAL DECK WITH POURED CONCRETE TOPPING & REBAR. NOÂ SPECIALÂ IN #39550642L | Mar 5, 2027 PENDING | $2,500 |
| Feb 20, 2026 | Construction CLASS - 1 GC 626425-OBSERVED ACTIVE JOBSITE IN SUPERSTRUCTURE PHASE CURRENTLY ON 4TH FLOOR. CELLAR LVL OF JOBSITE AND REAR YARD EXPO 3 HAS SOE WORK DONE. UPON REVIEW OF DOB RECORDS SOE PERMIT X0108062-S7-SE HAS OBJECTION #39550637R | Mar 5, 2027 | $2,500 |
| Feb 20, 2026 | Unknown CLASS - 2 3301.13.8- OBSERVED JOBSITE WITH MULTIPLE UNSAFE/VIOLATING CONDITIONS. JOBSITE WITH SOE WORK DONE W/OUT ISSUED PERMIT, WORK CONTRARY TO APPROVED PLANS, NO DESIGN DRAWINGS FOR TEMP STAIRS AND INADEQUATE FIRE EXT #39550659H | May 7, 2027 PENDING | $2,500 |
| Feb 20, 2026 | Construction CLASS - 1 GC-626425 (1704.1.2)- OBSERVED ACTIVE JOBSITE IN CURRENTLY @ 4TH FLOOR. WORK CONSIST OF COLD FORM STEEL AND DRAGON BOARD. UPON REVIEW OF DOB RECORDS THERE ARE NO SPECIAL INSPECTION REPORTS (TR1) FOR COLD FORM S #39550649Y | Mar 5, 2027 PENDING | $2,500 |
| Feb 20, 2026 | Construction CLASS - 2 GC 626425-ON ACTIVE JOBSITE OBSERVED INADEQUATE HOUSEKEEPING IN MULTIPLE LOCATIONS. REAR YARD OF JOBSITE WITH LARGE AMOUNT OF CMU AND OTHER CONSTRUCTION DEBRIS/MATERIALS. ON FLOORS OF JOBSITE CONSTRUCTION DEBRI #39550652P | Mar 5, 2027 | $1,250 |
| Feb 20, 2026 | Unknown CLASS - 2 GC 626425-(3301.6.2 DESIGN REQUIREMENTS)- OBSERVED ACTIVE JOBSITE WITH TEMPORARY WOODEN STAIRS INSTALLED FROM THE SECOND FLOOR TO FOURTH FLOOR. UPON REQUEST FROM ONSITE PERSONNEL FOR ENGINEER DESIGN DRAWINGS, N #39550654Z | Mar 5, 2027 | $2,500 |
| Jan 31, 2026 | Construction CLASS - 2 DURING MY INSPECTION OF A CLOSE 4-STORY NB SITE. I OBSERVED THE JOBSITE FENCE IN PLACE, NOT AS PER CODE 3307.7, AND NOT MAINTAINED WITH MAKESHIFT EXTENDED NETTING ON TOP. #39549753X | Nov 12, 2026 | $1,000 |
| Jan 2, 2026 | Construction CLASS - 2 ON ACTIVE JOBSITE OBSERVED STAY-FORM INSTALLED INTO FOUNDATION WALLS @ EXPOS 2&4. UPON REVIEW OF DOB APPROVED SOE PLANS PROVIDED, THERE ARE NO INDICATIONS FOR THE USE OF STAY FORM. STOP ALL SOE AND FOUNDATION W #39548644M | Mar 20, 2026 STIPULATION/IN-VIO | $0 |
| Jan 2, 2026 | Unknown CLASS - 2 3303.14.5 DEWATERING- ON ACTIVE JOBSITE OBSERVED LARGE AMOUNT OF STANDING WATER IN EXCAVATED AREA. NO DEWATERING MEASURES HAVE BEEN IMPLEMENTED TO REMOVE WATER FROM JOBSITE. STOP ALL SOE AND FOUNDATION OPERATIO #39548646X | Feb 1, 2027 | $2,500 |
| Jan 2, 2026 | Construction CLASS - 1 OBSERVED ACTIVE JOBSITE WITH EXCAVATED ELEVATOR PIT AREA. UPON REVIEW OF DOB RECORDS, THERE IS NO EARTHWORK NOTIFICATION PROVIDED. EXCAVATOR ONSITE SHOWS INDICATION OF USE TO DIG ELEVATOR PIT WHICH IS GREATER T #39548645Y | Feb 1, 2027 | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| May 6, 2020 | UNSAFE BUILDINGS #2009/20 | DOB VIOLATION - ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 23, 2026 | ECB | Construction: THE RESPONDENT HAS FAILED TO COMPLY WITH THE COMMISSIONER'S ORDER AND TO FILE A CERTIFICATION OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR A CLASS I VIOLATION ISSUED ON 02/20/2026. REF ECB: 39550649Y.FILE | Open |
| Aug 19, 2026 | ECB | Construction: GENERAL CONTRACTOR FAILED TO FILE CERTIFICATE OF CORRECTION WITH THE DOB. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION# 039550649Y-ISSUED 2-20-2026... | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 2:41 PM ET. BBL 2031220040.