Manhattan · Block 1414 · Lot 44 · 10022

206 East 60 Street

4 floors · 2 apartments · 4,075 sq ft · built 1910 · class K4 · owner of record: P.T.Z. Realty, Llc

20open violations
$38,750ECB/OATH penalties owed
0HPD class C (immediately hazardous)
44dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 44 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Required only if the owner doesn't live there
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-07 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (12) · $38,750 owed
IssuedViolationHearingBalance
Jun 12, 2026Construction CLASS - 2
UNABLE TO GAIN ACCESS. CERTIFICATE OF CORRECTION NOT SUBMITTED FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #35684597J ISSUED ON 2/7/2025 FOR LACK OF FIRE ALARM SYSTEM FOR TRANSIENT USE IN 2ND FLOOR APARTMENT., FI
#39192424X
May 20, 2027
PENDING
$1,250
Jun 12, 2026Construction CLASS - 2
NO ACCESS. CERTIFICATE OF CORRECTION HAS NOT BEEN OBTAINED FOR CLASS 1 OCCUPANCY CONTRARY VIOLATION #35684594Y ISSUED ON 2/7/2025, FOR THE 2ND FLOOR APARTMENT CONVERTED INTO TRANSIENT USE W/ 3 GUESTS BOOKED STA
#39192423Y
May 20, 2027
PENDING
$1,250
Jun 12, 2026Construction CLASS - 2
UNABLE TO GAIN ACCESS. CERTIFICATE OF CORRECTION NOT SUBMITTED FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #35684595X ISSUED ON 2/7/2025 FOR LACK OF REQUIRED MEANS OF EGRESS AT 2ND FLOOR APARTMENT, TRANSIENT USED
#39192422M
May 20, 2027
PENDING
$1,250
Jun 12, 2026Construction CLASS - 2
UNABLE TO GAIN ACCESS. CERTIFICATE OF CORRECTION NOT SUBMITTED FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #35684596H ISSUED ON 2/7/2025 FOR LACK OF AUTOMATIC SPRINKLER SYSTEM FOR TRANSIENT USE OF 2ND FLOOR APART
#39192425H
May 20, 2027
PENDING
$1,250
Aug 1, 2025Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY DEPT. OF BUILDINGS. NOTED: 2 FLOOR UNIT USED/CONVERTED TO TRANSIENT USE HAVING 3 GUESTS STAYING FOR LESS THAN 30 DAYS WITH NO HOST ON OWNER STAYING WITH THEM. NOTE GUEST BO
#35690189L
Jan 21, 2027
PENDING
$6,250
Aug 1, 2025Construction CLASS - 1
BC 907.2.8. FAILURE TO PROVIDE A FIRE ALARM SYSTEM FOR TRANSIENT USE AT 2 FLOOR UNIT. PREVIOUS VIOLATION 35684597J. REMEDY: DISCONTINUE ILLEGAL USE/OCCUPANCY.
#35690192M
Jan 21, 2027
PENDING
$6,250
Aug 1, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR AS PER BC 1018.1, BC 1021.1, BC 1006.3 AND 27-366 FOR TRANSIENT USE AT 2 FLOOR. PREVIOUS VIOLATION 356845
#35690190Z
Jan 21, 2027
PENDING
$6,250
Aug 1, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED AS PER BC 903.2, 27-954 FOR TRANSIENT USE AT 2 FLOOR UNIT. PREVIOUS VIOLATION 35684596H. REMEDY: DISC
#35690191K
Jan 21, 2027
PENDING
$6,250
Feb 7, 2025Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY DEPARTMENT OF BUILDINGS RECORDS.ILLEGAL OCCUPANCY NOTED AT 2ND FLOOR APARTMENT HAVING BEEN CONVERTED/OCCUPIED AS TRANSIENT WITH 3 GUEST BOOKED ON AIRBNB.COM STAYING FOR LES
#35684594Y
Apr 15, 2027
PENDING
$2,500
Feb 7, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. FAILURE TO PROVIDE THE REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR AS PER BC1018.1(2008); BC 1021.1(2014); BC 1006.3(2022) AND 27-366 FOR TRANSIEN
#35684595X
Apr 15, 2027
PENDING
$2,500
Feb 7, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF A SYSTEM AUTOMATIC SPRINKLERS WHERE REQUIRED AS PER BC 903.2 AND 27-954 FORTRANSIENT USE AT APARTMENT ON 2ND FLOOR. REMEDY: DISCONTINUE ILLEGAL O
#35684596H
Apr 15, 2027
PENDING
$1,250
Feb 7, 2025Construction CLASS - 1
BC 907.2.8. FAILURE TO PROVIDE THE REQUIRED FIRE ALARM SYSTEM FOR TRANSIENT USE AT 2ND FLOOR APARTMENT. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY.
#35684597J
Apr 15, 2027
PENDING
$2,500
DOB (3)
IssuedViolationStatus
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#02777
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#01332
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#04741
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 8)
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
Jan 6, 2006Boiler LL6291
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 7:13 PM ET. BBL 1014140044.