5 floors · 23,506 sq ft · built 1920 · class G1 · owner of record: Bldg East 38 Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 11, 2023 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01998, DATED 7/6/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11/202 #37025501J | Aug 15, 2024 IN VIOLATION | $0 |
| Jul 6, 2023 | Construction CLASS - 1 OBSERVED INSIDE OCCUPIED PARKING GARAGE ROTTED WOOD FLOOR AND BOEING OF WOOD JOIST AT ALL LEVELS. AT FONT OF BUILDING OBSERVED BRICK THAT AT LOOSE AT VARIOUS LOCATIONS ALSO OBSERVED STEP CRACKS AND SPAWLING STO #39089772R | Sep 14, 2023 ADMIT/IN-VIO | $0 |
| Jul 6, 2023 | Construction CLASS - 1 OBSERVED INSIDE OCCUPIED PARKING GARAGE SISTERING OF WOOD JOIST AT VARIOUS LOCATIONS AND ON MULTIPLE FLOORS. NO PERMIT ON FILE FOR THIS WORK, OBTAIN PERMIT #39089774K | Sep 14, 2023 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 6, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.FEU OHS VARIOUS CRCKS THRUOUT THE PERIMETER MASONRY WALLS.SOME OF THE INT WYTHE BRICKS WERE DISLOCATED&LOOSE.THE EGRESS SHAFTS&STAIRSWERE DETERIORATED.IMMEDIATELY COMPLY WITH THE COMMISSIONER'S ORDER 343572 (051024FEU10603ZT) TO REPAIR THE BUILDING UNDER #FEU10601ZT | DOB VIOLATION - ACTIVE |
| May 10, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.FEU OHS VARIOUS CRCKS THRUOUT THE PERIMETER MASONRY WALLS.SOME OF THE INT WYTHE BRICKS WERE DISLOCATED&LOOSE.THE EGRESS SHAFT&STAIRS WERE DETERIORATED.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,DETERMINE THE STRCTRL STBILITY, PREPARE/FILE RPAIR DWGS.B #FEU10603ZT | DOB VIOLATION - ACTIVE |
| Jul 6, 2023 | CONSTRUCTION OBSERVED INSIDE OF OCCUPIED PARKING GARAGE SISTERING OF WOOD JOIST AT ALL LEVEL, ROTTED WOOD FLOOR AND BOEING OF WOOD JOIST AT ALL LEVELS. AT FONT OF BUILDING OBSERVED BRICK THAT AT LOOSE AT VARIOUS LOCATIONS ALSO OBSERVED STEP CRACKS AND SPAWLING STONE SILL AT VARIOUS LOCATIONS. #23-01998 | DOB VIOLATION - ACTIVE |
| Jul 13, 2020 | CONSTRUCTION EMERG WORK:EXP4 APPRX 20'X6'HIGH SECT.BRICK FACADE@EXP1 COLLAPSED ONTO SIDEWLK 7/8/2020.ROOFING IN STATE DISRPR/CRACKED.REMAINING EXP1 FACADE NOT PROPERLY TIED/SECURE TO BACKUP WALL AND RISK OF COLLAPSE&DANGER TO PUBLIC.OWNER RTAIN NYSPE&LIC CONTRCT-IMMED ERCT SCAFLD&NET@EXP1&REMOVE LOOSE FACADE,TEM #FEU10601FF | DOB VIOLATION - ACTIVE |
| Jul 8, 2020 | CONSTRUCTION EMERG WORK:AT EXP1 APROX 20'LNGX6'HIGH OF BRICK VENEER PEELED OFF FROM ROOF LVL PART COLP INTO SIDWLK.AT ROOF LVL EXP1 PARPET ROOFING DISRPR& CRCK'D.BRICK VENEER FACADE NOT PROP TIED/SECURE TO BACK UP WALL @ RISK FURTH COLAPSE.OWNER HIRE PE&CONTR IMMED REMOVE ADDT'L LOOSE BRICKS IN COORD W/ NYC DEP& #FEU10601FF | DOB VIOLATION - ACTIVE |
| Jul 8, 2020 | CONSTRUCTION FTM SAFE COND:AT EXP1 APROX 20'LNGX6'HIGH BRICK VENEER PEELED OFF FROM ROOF LVL OF BLDG PART COLP INTO SIDWLK.AT ROOF LVL EXP1 PARPET ROOFING IN DISRPR&CRCKD.EXP1 BRCK VENEER FACDE IS NOT PROP TIED/SECURED BACKUP WALL AT RISK FURTH COLP.OWNER HIRE NYSPE&CONTR TO EVALUATE WHOLE BLDG OBTAIN PRMTS FOR #FEU10602FF | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Nov 25, 2024 | Parking Structures FTF-PS-INITL Failure to file sub cycle 1A compliance report by 12/31/2023 | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 3:08 PM ET. BBL 1009190006.