Brooklyn · Block 1822 · Lot 49 · 11216

202 Madison Street

5 apartments · 5,533 sq ft · built 2025 · class C2 · owner of record: Roz Aig Llc

13open violations
$47,400ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028

Open violations

ECB / OATH (18) · $47,400 owed
IssuedViolationHearingBalance
Sep 21, 2026Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE-EXPIRED PERMITRENEW PERMIT
#39559398J
Nov 25, 2026
PENDING
$1,250
Aug 28, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION, NO ACCESS OBTAINED, CONTRACTOR FAILED TO COMPLY WITH COMMISSIONER'S ORDER. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION#039556033N ISSUED ON 7.01.2026...
#39558497K
Nov 4, 2026
PENDING
$1,250
Aug 28, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION, NO ACCESS OBTAINED, CONTRACTOR FAILED TO COMPLY WITH COMMISSIONER'S ORDER. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION#039556034P ISSUED ON 7.01.2026 ..
#39558499Y
Nov 4, 2026
PENDING
$1,250
Aug 4, 2026Construction CLASS - 2
ATOI OBSERVED AT EXPOSURE 1 OF CONSTRUCTION SITE, FULLY ERECTED SIDEWALK SHED UNDER APPLICATION#B00981725 EXP DATE 07/02/2026. NOV ISSUED FOR EXPIRED TEMPORARY EQUIPMENT., RENEW PERMIT; RENEW PERMIT
#39199107Y
Nov 25, 2026
PENDING
$1,250
Jul 28, 2026Unknown CLASS - 2
UPON INSPECTION OF A NON-ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED A FENCE INSTALLED AT EXPOSURE 1 THAT DID NOT FULLY ENCLOSE ON GOING CONSTRUCTION WORK AND POTENTIAL HAZARDS CONTRARY TO CODE 3307.7 FENCE
#39557166L
Oct 7, 2026
IN VIOLATION
$2,500
Jul 28, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 INSTALLED CONTRARY TO CODE. 8FT MIN HEIGHT REQUIREMENT NOT MAINTAINED INFRONT OF ADJOINING PROPERTY AT EXPOS 2 CONTRARY TO CODE 3307.6.4.7. DRIVEW
#39557168P
Oct 7, 2026
IN VIOLATION
$2,400
Jul 28, 2026Unknown CLASS - 1
I OBSERVED A SIDEWALK SHED NOT MAINTAINED AND BEING USED IN SAFE CONDITION CONTRARY TO CODE 3307.6.5.1 SAFE CONDITION. MULTIPLE ROTTED MUDSILLS. LARGE ROLLING GATE UNSAFELY ATTACHED TO SHED CREATING A POTENTIAL
#39557169R
Mar 5, 2027
PENDING
$5,000
Jul 1, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF THE ACTIVE 4-STORY JOB SITE, GUARDRAIL SYSTEMS WERE MISSING AT MULTIPLE LOCATIONS, INCLUDING ELEVATOR SHAFTS AND STAIRWAY OPENINGS, CREATING AN IMMEDIATE HAZARD TO WORKERS. STOP ALL
#39556034P
Oct 21, 2026
$5,000
Jul 1, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OF THE ACTIVE 4-STORY JOB SITE, DEBRIS WAS OBSERVED THROUGHOUT THE SITE, CREATING TRIPPING, FIRE, AND SAFETY HAZARDS TO WORKERS, THE PUBLIC, AND PROPERTY. STOP ALL WORK, MAINTAIN PROPE
#39556035R
Oct 21, 2026
PENDING
$1,250
Jul 1, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION OF THE ACTIVE 4-STORY JOB SITE, OVERHEAD PROTECTION WAS MISSING AT EXPOSURE 1, THE CORNERS OF EXPOSURES 1/2 AND 1/4, AND THE REAR OF EXPOSURES 2 AND 4, CREATING AN IMMEDIATE HAZARD TO
#39556033N
Oct 21, 2026
PENDING
$10,000
Apr 24, 2026Unknown CLASS - 2
OBSERVED EXP #1 OFFICE TRAILER ON THE STREET, BUT NO DEPT OF TRANSPORTATION PERMITS ON SITE (BC 3307.1), NO JERSEY BARRIERS ENCLOSURE, CONTRARY TO SSP PLAN. STOP ALL STREET OPERATION ON EXP #1. OBTAIN DOT PERMI
#39553453X
Jul 1, 2026
IN VIOLATION
$625
Apr 24, 2026Construction CLASS - 1
OBSERVED EXP #3 FOUNDATION WALL IN PLACE BUT NO GUARDRAIL ON GRADE. FALLING OVER 6FT WAS A SURE HAZARD FOR WORKERS. STOP WORK ON EXP#3 AND STAY 10 FT FROM THE LEADING EDGE.
#39553452Y
Jul 1, 2026
IN VIOLATION
$5,000
Aug 21, 2025Construction CLASS - 1
OBSERVED SOE AT EXP#2 CONTRARY TO APPROVE DOCUMENTS. INDICATE 5 SOLDIER PILES. SITE ADD H PILE GO TO DETAIL 1A SOE-200., CONFORM WORK TO APPROVED CONSTRUCTION DOCUMENTS/AMENDMENTS; STOP ALL WORK UNDER PERMIT B0
#39157984K
Nov 6, 2026
$2,500
Jul 22, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED: EXCAVATION WORK IN PROGRESS UNDER PERMIT# B00797380-S4-FO-EA UPON REVIEWED DEPARTMENT RECORD NOT EARTHWORK NOTIFICATION CREATING UNSAFE CONDITION FOR SAFETY MONITORING AND COMPLI
#39542687P
Oct 1, 2025
IN VIOLATION
$2,500
Mar 3, 2025Construction CLASS - 2
UPON ARRIVAL OF DEMO SAFETY MONITORING INSPECTION #B00896730 I OBSERVED A CLOSED JOB SITE. NO WORK BEING PERFORMED. UPON FURTHER RESEARCH I SAW THAT SIDEWALK SHED PERMIT IN PLACE WITH AN EXPIRED PERMIT. COMPLY
#39537512R
Oct 6, 2025
IN VIOLATION
$1,250
Mar 3, 2025Unknown CLASS - 2
REVIEWED DOBNOW SWS PERMIT B00981725 ,REVEALED SWS PERMIT EXPIRED 01/11/2025 AND WAS NOT RENEWED. RENEWED SWS PERMIT
#39537532Y
Jun 18, 2026
IN VIOLATION
$1,250
Mar 4, 2022Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOL TION #35560905H ISSUED 05/18/21 AND FILE CERTIFICATE OF CORRECTION PU SUANT TO 28-201.1 AND 1RCNY 102-01.FOR WORK W/O A PERMIT.NOTE:JOB #B0
#35569467H
Oct 21, 2022
DEFAULT
$3,125
Oct 2, 2020Zoning CLASS - 3
PLANTING REQUIREMENTS.PLANTING AREA AT FRONT YARD HAS BEEN REMOVED ANDFILLED IN WITH MASONRY TILES.THE ENTIRE FRONT YARD WAS OBSERVED COVERED.REM:COMPLY WITH PLANTING REQUIREMENTS AS PER ZONING.
#35501372Y
Feb 10, 2021
DEFAULT
$0
DOB (1)
IssuedViolationStatus
Jan 19, 2021CONSTRUCTION
AT TIME OF INSPECTION OBSERVED DAMAGE TO THE BACK EXTERIOR WALL DUE TO CONSTRUCTION CAUSED THE WALL TO SEPARATE AND SHIFT APPROXIMATELY 12 INCHES . AS A RESULT THE FIRE WALL BETWEEN THE PROPERTIES IS COMPROMIS EDAND UINSAFE TO RESIDE IN. THE RESULT OF DAMAGE DUE TO CONSTRUCTION HAS RENDERED THIS STR
#CER02ND
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 21, 2026ECBConstruction: TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE-EXPIRED PERMITRENEW PERMITOpen
Aug 28, 2026ECBConstruction: AT THE TIME OF INSPECTION, NO ACCESS OBTAINED, CONTRACTOR FAILED TO COMPLY WITH COMMISSIONER'S ORDER. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION#039556033N ISSUED ON 7.01.2026...Open
Aug 28, 2026ECBConstruction: AT THE TIME OF INSPECTION, NO ACCESS OBTAINED, CONTRACTOR FAILED TO COMPLY WITH COMMISSIONER'S ORDER. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION#039556034P ISSUED ON 7.01.2026 ..Open
Aug 4, 2026ECBConstruction: ATOI OBSERVED AT EXPOSURE 1 OF CONSTRUCTION SITE, FULLY ERECTED SIDEWALK SHED UNDER APPLICATION#B00981725 EXP DATE 07/02/2026. NOV ISSUED FOR EXPIRED TEMPORARY EQUIPMENT., RENEW PERMIT; RENEW PERMITOpen
Jul 28, 2026ECBUnknown: UPON INSPECTION OF A NON-ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED A FENCE INSTALLED AT EXPOSURE 1 THAT DID NOT FULLY ENCLOSE ON GOING CONSTRUCTION WORK AND POTENTIAL HAZARDS CONTRARY TO CODE 3307.7 FENCEOpen
Jul 28, 2026ECBConstruction: UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 INSTALLED CONTRARY TO CODE. 8FT MIN HEIGHT REQUIREMENT NOT MAINTAINED INFRONT OF ADJOINING PROPERTY AT EXPOS 2 CONTRARY TO CODE 3307.6.4.7. DRIVEWOpen
Jul 28, 2026ECBUnknown: I OBSERVED A SIDEWALK SHED NOT MAINTAINED AND BEING USED IN SAFE CONDITION CONTRARY TO CODE 3307.6.5.1 SAFE CONDITION. MULTIPLE ROTTED MUDSILLS. LARGE ROLLING GATE UNSAFELY ATTACHED TO SHED CREATING A POTENTIALOpen
Jul 1, 2026ECBConstruction: AT THE TIME OF INSPECTION OF THE ACTIVE 4-STORY JOB SITE, GUARDRAIL SYSTEMS WERE MISSING AT MULTIPLE LOCATIONS, INCLUDING ELEVATOR SHAFTS AND STAIRWAY OPENINGS, CREATING AN IMMEDIATE HAZARD TO WORKERS. STOP ALLClosed
Jul 1, 2026ECBConstruction: AT THE TIME OF INSPECTION OF THE ACTIVE 4-STORY JOB SITE, DEBRIS WAS OBSERVED THROUGHOUT THE SITE, CREATING TRIPPING, FIRE, AND SAFETY HAZARDS TO WORKERS, THE PUBLIC, AND PROPERTY. STOP ALL WORK, MAINTAIN PROPEOpen
Jul 1, 2026ECBUnknown: AT THE TIME OF INSPECTION OF THE ACTIVE 4-STORY JOB SITE, OVERHEAD PROTECTION WAS MISSING AT EXPOSURE 1, THE CORNERS OF EXPOSURES 1/2 AND 1/4, AND THE REAR OF EXPOSURES 2 AND 4, CREATING AN IMMEDIATE HAZARD TOOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 1:33 PM ET. BBL 3018220049.

Look up another building