5 floors · 94,750 sq ft · built 1923 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 94,750 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 434 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5371). Agency page | Dec 31, 2031 in 1895 days | Next due 2031 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-01 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 18, 2026 | Construction CLASS - 2 REISSUE ECB #35725491J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: AT(BASEMENT) BOILER RM JUMP PIT ACCESS/COVER ROTTCO/DETERIORATING/CORRODED. REMEDY: COMPLY WITH CODE. #35728963M | Mar 18, 2026 POP/IN-VIO | $0 |
| Feb 18, 2026 | Construction CLASS - 2 REISSUE ECB #35725492L. EXIT DOOR NOT SELF-CLOSING. NOTED: AT(1ST FL) EXIT 6 AND 4 DOORS NOT CLOSING WHEN TESTED. REMEDY: REPAIR/REPLACE DOOR. #35728962K | Mar 18, 2026 POP/IN-VIO | $0 |
| Feb 18, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT(3RD FL) EXIT 6(2ND FL) G AND D(1ST FL) EXIT F, AUDITORIUM ALL DOORS ARE IN DISREPAIR/RACKED. REMEDY: REPAIR AND/OR REPLACE. #35728964Y | Mar 18, 2026 POP/IN-VIO | $0 |
| Feb 18, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: AT(1ST FL) CAFETERIA/GYM AREAS AND AUDITORIUM THE EMERGENCY LIGH #35728965X | Mar 18, 2026 POP/IN-VIO | $0 |
| Oct 2, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT CELLARLEVEL BOILER ROOM, SUMP, PIT COVER WAS HEAVILY CORRODED WITH HOLES. POSES TRIPPING/FALLING HAZARD, RESULTING IN INJURY. REMEDY: REPAIR AND/O #35725491J | Oct 27, 2025 POP/IN-VIO | $0 |
| Oct 2, 2025 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED EXTERIOR DOOR AT EXIT #6 RUBS ON SADDLE, CAUSING IT TO NOT SELF-CLOSE OR OPEN PROPERLY. ADDITIONALLY MAIN ENTRANCE SMOKE DOORS ARE RACHED/RUB ON FRAME AND STAY AJAR. REMEDY: RE #35725492L | Oct 27, 2025 POP/IN-VIO | $0 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 8:51 PM ET. BBL 3053710001.