4 floors · 5 apartments · 3,000 sq ft · built 1900 · class C2 · owner of record: Ross, Robert
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 63 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 63 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 79 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-26 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #07344 | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT #08266 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #10709 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #08051 | DOB VIOLATION - ACTIVE |
| Mar 26, 2002 | LOCAL LAW 62/91 - BOILERS #13707 | DOB VIOLATION - ACTIVE |
| Mar 16, 1999 | LOCAL LAW 62/91 - BOILERS #13121 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #21237 | DOB VIOLATION - ACTIVE |
| Sep 16, 1997 | LOCAL LAW 62/91 - BOILERS #212155 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #17231 | DOB VIOLATION - ACTIVE |
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #29146 | DOB VIOLATION - ACTIVE |
| Jun 1, 1994 | LOCAL LAW 62/91 - BOILERS #12683 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #27691 | DOB VIOLATION - ACTIVE |
| Jun 1, 1993 | LOCAL LAW 62/91 - BOILERS #12682 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| Mar 3, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Mar 26, 2002 | Boiler LL6291 | Active |
| Mar 16, 1999 | Boiler LL6291 | Active |
| May 4, 1998 | Boiler LL6291 | Active |
| Sep 16, 1997 | Boiler LL6291 | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| Aug 29, 1995 | Boiler LL6291 | Active |
| Jun 1, 1994 | Boiler LL6291 | Active |
| Jun 1, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 1, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 4, 2026 |
| Jun 6, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 9, 2025 |
| Apr 9, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 13, 2024 |
| Mar 21, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 24, 2023 |
| Feb 23, 2022 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | May 29, 2022 |
| Apr 7, 2021 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 11, 2021 |
| Jun 5, 2008 | B | Apt 4 · D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK 2 STY WEST APT 4 KITCHEN. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 4 · D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR 2 STY WEST APT 4 BATHROOM. , SECTION '' '' | Sep 8, 2008 |
| Jun 5, 2008 | A | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WOOD CORNICE ROOF FRONT. | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 1R · D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 1 STY REAR APT 1R. LOCATED AT APT 1R | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 1R · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS 1 STY REAR APT 1R KITCHEN. LOCATED AT APT 1R | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 1R · D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR 1 STY REAR APT 1R KITCHEN. LOCATED AT APT 1R | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 1R · D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK 1 STY REAR APT 1R KITCHEN. LOCATED AT APT 1R | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 1R · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 1 STY REAR APT 1R. LOCATED AT APT 1R | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 1R · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD DOOR 1 STY REAR APT 1R BATHROOM. LOCATED AT APT 1R | Jul 10, 2008 |
| Jun 5, 2008 | A | D26-21.03 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALL AT OR NEAR STAIRS ALL STYS PUBLIC HALL. | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 4R · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS 3 STY REAR APT 4R FRONT ROOM. LOCATED AT APT 4R | Jul 10, 2008 |
| Jun 5, 2008 | C | Apt 4R · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED ENTRANC DOOR TO 3 STY REAR APT 4R. LOCATED AT APT 4R | Jun 11, 2008 |
| Jun 5, 2008 | B | Apt 4R · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW FRAMES & SASHES 3 STY REAR APT 4R REAR ROOM. LOCATED AT APT 4R | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 4R · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 3 STY REAR APT 4R. LOCATED AT APT 4R | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 2F · D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASHBASIN 2 STY FRONT APT 2F BATHROOM. LOCATED AT APT 2F | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 2F · D26-20.05 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD 2 STY FRONT APT 2F. LOCATED AT APT 2F | Sep 8, 2008 |
| Jun 5, 2008 | A | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILINGS ALL STYS PUBLIC HALL. | Sep 8, 2008 |
| Jun 5, 2008 | A | D26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING. | Sep 8, 2008 |
| Jun 5, 2008 | C | D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR. | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-17.10 ADM CODE PROVIDE READY ACCESS TO BUILDING'S HEATING SYSTEM CELLAR DOOR LOCKED. | Jun 11, 2008 |
| Jun 5, 2008 | A | Apt 6 · D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING & WALL 3 STY WEST APT 6 KITCHEN. , SECTION '' '' | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 2F · D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES 2 STY FRONT APT 2F THRU OUT. LOCATED AT APT 2F | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 4 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & WALLS BATHROOM 2 STY WEST APT 4. , SECTION '' '' | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 4 · D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES THRU OUT 2 STY WEST APT 4. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 4 · D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASHBASIN 2 STY WEST APT 4 BATHROOM. , SECTION '' '' | Jul 10, 2008 |
| Jul 28, 2006 | A | Apt 5 · SECTION 27-2005 ADM CODE REFIT DOOR ENTRANCE 3 STY REAR APT 5. LOCATED AT APT 5 | Nov 24, 2006 |
| Jul 17, 1990 | C | Apt 5 · SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED ENTRANCE DOOR 3 STY REAR APT 5. LOCATED AT APT 5 | Aug 6, 1990 |
| Jul 17, 1990 | B | Apt 5 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EXTERIOR SILL NORTH WINDOW 3 STY REAR APT 5 REAR ROOM. LOCATED AT APT 5 | Sep 3, 1990 |
| Jul 17, 1990 | B | SECTION 27-2044 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 3 STY REAR APT 5. | Sep 3, 1990 |
| Jul 17, 1990 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR 1 STY PUBLIC HALL. | Sep 3, 1990 |
| Jul 17, 1990 | B | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 1 STY PUBLIC HALL. | Sep 3, 1990 |
| Jul 17, 1990 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING FIXTURES PRESENT LIGHTS NOT ON NIGHT INSPECTION. | Sep 3, 1990 |
| Jul 17, 1990 | B | Apt 5 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILINGS THRU OUT 3 STY REAR APT 5. LOCATED AT APT 5 | Sep 3, 1990 |
| Aug 25, 1987 | C | Apt 2F · D26-12.01 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING CENTER ROOM & WALL BATHROOM 2 STY FRONT APT 2F NURSE NO PHONE. LOCATED AT APT 2F | Sep 14, 1987 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)