Manhattan · Block 1675 · Lot 2 · 10029

2002 2 Avenue

4 floors · 6 apartments · 5,660 sq ft · built 1920 · class S9 · owner of record: Morris Park Holding Llc

7open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 70 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 86 days
Annual
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 435 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-19 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (2)
IssuedViolationStatus
Sep 24, 2026CONSTRUCTION
CORRECTIVE ACTION PLAN REQ'D-OBSVD DISLODGED BRICKS AT EXP1/2 CORNER ABOVE 4FL. OBSVD DETERIORATED MORTAR JOINTS AND CRACKS IN MASONRY AT VARIOUS LOCATIONS THROUGHOUT EXP1 AND 4. OWNER TO IMMED RETAIN RDP IN GOOD STANDING WITH DOB &NYS TO EVAL ENTIRE BLDG AND SUBMIT A CORRECTIVE ACTION PLAN BY 10/7/
#PI11101TC
DOB VIOLATION - ACTIVE
Apr 5, 2018UNSAFE BUILDINGS

#1001/18
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
HPD (3) · C 2 · B 1 · A 0
IssuedClassViolationCorrect by
Mar 20, 2024C§27-2005 (E) HMC: PROVIDE WRITTEN NOTICE TO THE TENANTS AT LEAST TWENTY-FOUR HOURS PRIOR TO ESSENTIAL SERVICE INTERRUPTION BY POSTING A NOTICE IN A PROMINENT PLACE WITHIN THE PUBLIC PART OF THE BUILDING AND ON EACH FLOOR OF SUCH BUILDING, WHERE AN OWNER MUST MAKE A REPAIR THAT MAY RESULT IN AN INTERMar 26, 2024
Mar 20, 2024B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AT 2ND STORY ROPE TIED AROUND DROP LADDER AT FIRE ESCAPE, 2nd STORYApr 24, 2024
Apr 21, 2021CApt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMay 17, 2021

Issued in the last 120 days

DateSourceWhatNow
Sep 24, 2026DOBCONSTRUCTION: CORRECTIVE ACTION PLAN REQ'D-OBSVD DISLODGED BRICKS AT EXP1/2 CORNER ABOVE 4FL. OBSVD DETERIORATED MORTAR JOINTS AND CRACKS IN MASONRY AT VARIOUS LOCATIONS THROUGHOUT EXP1 AND 4. OWNER TO IMMED RETAIN RDP IN GOOD STANDING WITH DOB &NYS TO EVAL ENTIRE BLDG AND SUBMIT A CORRECTIVE ACTION PLAN BY 10/7/Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 7:43 PM ET. BBL 1016750002.

Look up another building