4 floors · 58,660 sq ft · built 1931 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 58,660 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 775 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 423). Agency page | Dec 31, 2033 in 2601 days | Next due 2033 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-08 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 10, 2026 | Construction CLASS - 2 RE-ISSUE #35692174H. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: A STRUCTURAL GIRDER BEAM AT THE STAIR LANDING NEAR RM/DOOR #153 IS EXPOSED FROM DETERIORATION OF THE OUTER/COVER MATERIALS. THI #35724921X | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 10, 2026 | Construction CLASS - 2 RE-ISSUE #35692173X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: AT THE BOILER RM, OUTSIDE THE ELECTRIC ROOM, THERE ARE SEVERAL PENETRATIONS THRU WALLS T #35724922H | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 10, 2026 | Construction CLASS - 2 RE-ISSUE #35692172Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: IN THE MUSIC RM., THE DOOR LEADING TO THE BLOWER RM. AND THE SMOKE DOOR AT THE 4TH FLOOR STAIR F ARE NOT CLOSING PROPERLY. REME #35724923J | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 7, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT T. O.I. THE DOOR TO THE BLOWER RM. INSIDE THE MUSIC ROOM AND THE SMOKE DOORAT 4TH FLOOR STAIR F ARE NOT CLOSING. PROPERLY. REMEDY: REPAIR/REPLACE #35692172Y | Apr 29, 2025 POP/IN-VIO | $0 |
| Feb 7, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: AT THE BOILER RM, OUTSIDE THE ELECTRIC ROOM THERE ARE SEVERAL PENETRATIONS THAT REQUIRE FIRE STOPPING. REMEDY #35692173X | Apr 29, 2025 POP/IN-VIO | $0 |
| Feb 7, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT T. O.I. THERE IS A GIRDER/BEAM THAT CAN BE SEEN ON THE LANDING OF THE STAIRCASE THRU ROOM/DOOR #153. THE BEAM IS EXPOSED FROM CEILING AT THE LAND #35692174H | Apr 29, 2025 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 19, 2003 | Boiler LL6291 | Active |
None open.