5 floors · 4 apartments · 11,300 sq ft · built 1915 · class S4 · owner of record: 20 Warren Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 63 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 79 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 307 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 794 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 21, 2021 | Construction CLASS - 2 FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OFCORRECTION W/ THE DOB FOR VIOLATING CONDITIONS CITED ON NOV#35437831K ISSUED ON 7/1/19 PURSUANT TO SECTION:28-201.1;28-204.2;1RCNY 102.01. R #35590305L | Jul 21, 2022 IN VIOLATION | $1,250 |
| Jan 23, 2020 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED NEW PARTITION WALL AND DOOR ERECTED CREATING 2 SEPARATE ROOMS ON THE 3RD FLOOR APARTMENT OF THE BUILDING. NO PERMIT ON FILE WITH THE DEPARTMENT OF BUILDINGS FOR THIS WORK. NON CO #39016206P | Mar 12, 2020 IN VIOLATION | $1,250 |
| Apr 19, 2019 | Construction CLASS - 3 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS. AT TIME OF INSPECTION,OBSERVED A MAKE SHIFT PLATFORM ATTACHED TO THE CONSTRUCTION FENCE. ADD ONTO THE FENCE DOES NOT CONFORM #35373557R | Aug 29, 2019 ADMIT/IN-VIO | $0 |
| Jun 19, 2017 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVED AMENDMENTS FOR ALT-1 JOB#121958694 AT CELLAR LEVEL LOCATION OF BATHROOMS,OFFICES,LAYOUT ALSO WORK DOES NOT CONFORM TO PROPOSED SCHEDULE FOR #35257887L | Jun 7, 2018 IN VIOLATION | $0 |
| Aug 5, 2010 | Elevators CLASS - 1 21-N-10/12-M-07/21-N-10-DEFECTIVE BSMT DOOR LOCK-AT A RESULT THE USE OF PAPER LODGED SIDE IN ORDER FOR DEVICE TO OPERATE (BY PASSED)CEASE USE-CALL DOB BEFORE RETURNING BACK TO SERVICE 1-212-566-5542/12-M-07-PRO #38212146Y | Mar 24, 2011 IN VIOLATION | $0 |
| May 14, 2010 | Elevators CLASS - 1 97B17,12M07,16F01,100I11. 97B- DURING MY INSPECTION THE ELEVATOR DRIFTED ONTO THE OVERHEAD FINALS. APPARENTLY THIS CONDITION HAPPENED ONCE BEFORE THEREFORE (CEASE USE) A REINSPECTION IS REQUIRED CALL THE DEPT #38209949K | Apr 29, 2011 IN VIOLATION | $0 |
| Dec 9, 2009 | Elevators CLASS - 1 21N10.52BB12.59Y11.21B06 21N BSMT INTERLOCK BYPASSED C/U 52B RESHACKLE HOIST ROPES 59Y REPLACE OIL SOAKED BRAKE PADS 56Y GEAR CASE OIL LEAK 37B PROVIDE SALE ACCESS AS PER CODE 21B06 PROPERLY SECURE 5FL INTERLOC #38206983K | Jan 28, 2010 DEFAULT | $0 |
| Dec 2, 2009 | Construction CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS:NOTED;AT CELLAR WORK DOES NOT CONFORM TO JOB #104133509 APP-7/26/05 OR AMENDED PLANS UNDER JOB #104635904 APP-12-05-07 REMOVAL #34816930J | Jan 6, 2011 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #01685 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #01764 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #34832 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #14532 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #14809 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #35678 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #05216 | DOB VIOLATION - ACTIVE |
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #02190 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #03287 | DOB VIOLATION - ACTIVE |
| Feb 24, 2017 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT #02351 | DOB VIOLATION - ACTIVE |
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #02022 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #00444 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #00072 | DOB VIOLATION - ACTIVE |
| Jun 25, 1992 | CONSTRUCTION #A3BL02 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Feb 24, 2017 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 29, 2020 | C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING GRAVITY HOOK AT DROP LADDER AT BUILDING FRONT AT FIRE ESCAPE | Feb 6, 2020 |
| Jan 24, 2020 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF IRON BAR OBSTRUCTING THE FIRE ESCAPE DROP LADDER AT BUILDING FRONT | Feb 1, 2020 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)