6 floors · 49 apartments · 42,115 sq ft · built 1938 · class D1 · owner of record: L & H Realty
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-09 (Accepted). Agency page | Dec 31, 2026 in 67 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 42,115 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 432 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 5, 2026 | Construction CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39161647L ISSUED ON 09-25-2025 FOR TAMPERED WITH, REMOVED OR DEFACED A WRITTEN POSTED STOP WORK ORDER.( NO STICKER FOUND ), FILE A CERTIFICATE OF CORREC #39206738N | Dec 10, 2026 PENDING | $1,250 |
| Oct 5, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION NO OBSTRUCTION AT EXPOSURE # 4 HOWEVER FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39086235H ISSUED ON 05-11-2023 FOR FAILURE TO PROVIDE AN UNOBSTRUCTED EXIT PASSAGEWAY., FIL #39206737L | Dec 10, 2026 PENDING | $1,250 |
| Sep 26, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED AT MAIN ENTRY DOOR THE REMOVAL/TAMPERING & DEFACED OF ACTIVE POSTED FULL STOP WORK ORDER .NOTICE (ISSUED UNDER COMPLAINT# 1543175) ON 05/15/2020 BY BADGE #3099 WITH SUMMONS # 3546 #39161647L | Jun 28, 2027 DEFAULT | $25,000 |
| Jul 18, 2025 | Elevators CLASS - 2 CLASS 2: DOOR OPEN BUTTON MISSING INSTALL NEW BUTTON. ADJUST CAR DOOR TO REMOVE GAPS. MAINTANENCE COMPANY REMOVED STICKER FROM MAINLINE. SHOW EVIDENCE OF VALID MAINTANENCE CONTRACT & TAG MAINLINE. FIRE EXTINGUI #39154172L | Oct 23, 2025 IN VIOLATION | $625 |
| Mar 5, 2025 | Elevators CLASS - 2 CLASS 2: CAR DOOR MISALIGNED CREATING LARGE GAP ADJUST TO REMOVE. DOORCLOSE BUTTON MISSING ON CAR BUTTON STATION INSTALL NEW BUTTON. CARTOP LIGHT DAMAGED REPAIR. REMOVE NON ELEVATOR STORAGE FROM MOTOR ROOM. RE #39140448X | May 15, 2025 IN VIOLATION | $625 |
| Dec 17, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR, BUILDING FACADE AND APPURTENANCES. NOTE:OBSERVED AT EXPOSURE 1, AOUTH ELEVATION SPALLING WINDOW SILLS. AT EXPOSURE 2, WEST ELEVATION OBSERVED CRACKS IN MASONRY AND DETERIORATED MOR #35689311H | Jun 28, 2027 DEFAULT | $6,250 |
| Aug 5, 2024 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED SIDEWALK SHED IN PLACE, MISSING CAPS FROM THE BOLTS 3307.6.5.6 SHARP EDGES AT SIDEWALK SHED CREATE HAZARDOUS CONDITION FOR PEDESTRIAN .. #39531068M | Dec 5, 2024 IN VIOLATION | $2,400 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8C AND 9C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#914058.REM:FILE ACCEPTABLE REPORT. #37026261Y | Apr 18, 2024 DEFAULT | $6,250 |
| May 12, 2023 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EGRESS PASSAGEWAY. 8'-0" TALL PLYWOOD FENCE HAS BEEN ERECTED AT EXP #4 OF PROPERTY AND EXTENDS FULL WIDTH OF EGRESS PATHWAY, ADDITIONALLY THERE IS A LARGE QUANTITY OF HOUSEHOLD / #39086235H | Jun 28, 2027 DEFAULT | $6,250 |
| Mar 14, 2023 | Elevators CLASS - 2 CLASS 2: CAR DOOR MISALIGNED. ADJUST DOOR TO CLOSE GAPS TO CORRECT CLEARANCES. EMERGENCY LIGHT DAMAGED ON CAR BUTTON STATION. REPLACE WITH NEW LIGHT & TEST. CAB MIRROR DAMAGED & FADED. REPLACE WITH NEW MIRROR. #39081432Y | May 18, 2023 IN VIOLATION | $625 |
| Feb 22, 2023 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY W/ COMMISSIONER'S ORDER. ECB VIO:35669492H ISSUED ON 12/29/22 REQUIRED THE OWNER TO PROVIDE ADEQUATE SAFETYMEASURES TO PROTECT PUBLIC AND PROPERTY FROM DOCUMENTED UNSAFE FACADE. #35670658R | Jul 16, 2024 IN VIOLATION | $1,250 |
| Dec 29, 2022 | Construction CLASS - 1 FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES,SUCH AS SHED,NETTING,ETC,WHERE REQUIRED TO PROTECT AND SECURE PUBLIC SAFETY FROM DOCUMENTED UNSAFE FACADE AS PER 1RCNY 103-04.FACADE TECHNICAL REPORT#914058-9C-001 FI #35669492H | Mar 21, 2024 IN VIOLATION | $10,000 |
| Oct 19, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#814058. REMEDY:SUBMIT ACCEPTABLE REQUIR #37023032R | Feb 9, 2023 DEFAULT | $10,000 |
| May 15, 2020 | Construction CLASS - 1 WORK W/O A PERMIT NOTE: @TIME OF INSPECTION OBSERVED @ 20 BOGARDUS PLACE ON APT 3D, RENOVATION WORK WHICH INCLUDED ELECTRICAL WORK NEW CURCUIT BOX, NEW OUTLETS, SWITCHES, & CEALING FIXTURST ALSO OBSERVED NEW #35466344X | Jul 23, 2020 DEFAULT | $12,500 |
| May 15, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED @20 BOGARDUS PL REAR OF BUILDING COMBUSTABLE MATERIAL STACKED AGAINST FENCE; WOO STIPS, DOORS, 2*4 ETC. NEW MATERIAL STORED IN LOBBY COMPOUND #35466345H | Jul 23, 2020 DEFAULT | $6,250 |
| Feb 13, 2020 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#814058. REMEDY: SUBMIT ACCEPTABLE REQUIRE #37018725N | Oct 29, 2020 DEFAULT | $6,250 |
| Dec 18, 2014 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS. NOTED EXCESSIVE CRACKING EVIDENT THROUGHOUT EXPOSURE (2,3,4) IN MASONRY BRICK, SECTIONS ARE CRACKED, SEPARATING LOOSE & BULGING THROUGH OUT ALL LEVELS NEAR WINDOWS & THROUGH OUT #35117307L | Feb 5, 2015 IN VIOLATION | $0 |
| Sep 2, 2013 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS. NOTED: @ REAR & SIDE OF PREMISES MASONRY WALLS ARE CRACKED,LOOSE,BULGING IN VARIOUS LOCATIONS @ TIME OF INSPECTION. REMEDY: MAINTAIN EXTERIOR BLDG WALL SUBMIT ENGINEERS RESPOND #35030367L | Oct 17, 2013 IN VIOLATION | $0 |
| Nov 5, 2010 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.NOTED:2 UNSTABLE MARBLE PANELS,EACH APPROX 5'HIGH X 3'WIDE.LOCATED @ OPPOSITE SIDES OF THE BLDG ENTRY DOOR.NOTE:MARBLE PANELS ARE APPROX 2' ABOVE DOOR.MAINTAIN #34884596H | Dec 30, 2010 DEFAULT | $0 |
| Nov 5, 2010 | Unknown CLASS - 2 FAILURE TO COMPLY W/ COMM'S ORDER TO FILE A CERT OF CORRECTION W/ THE DOB.NOTED:RESPONDENT FAILED TO COMPLY W/ THE ORDER TO CORRECT THE VIOLATING CONDITIONS & FILE A CERT OF CORRECTION PURSUANT TO 28-204.2 FOR #34884597J | Dec 30, 2010 DEFAULT | $0 |
| Sep 9, 2010 | Construction CLASS - 2 FAILURE TO COMPLY W/ THE COMM'S ORDER TO FILE A CERT OF CORRECTION W/ DOB NOTED: RESPONDENT FAILED TO COMPLY W/ THE COMM'S ORDER TO CORRECT THE VIOLATING CONDITIONS & FILE A CERT OF CORRECTION, PURSUANT TO #34876792P | Jul 7, 2011 IN VIOLATION | $0 |
| Sep 9, 2010 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES NOTED: 2 DISLODGED MARBLE WALL PANELS APPROX 5'HX3'W EACH ABOVE BOTH SIDES OF ENTRY DOOR THROUGHOUT FRONT FACADE OF BLDG 2 VERTICAL & DIAGONAL CRACKS EACH APPROX #34876791N | Jul 7, 2011 IN VIOLATION | $0 |
| May 12, 2010 | Construction CLASS - 1 FAIL TO MAINTAIN EXTERIOR BLDG WALL. DEFECT IS: BULGING & CRACKED BRICK WALL & RUSTED STEEL LINTELS ALL FOUR SIDES OF BLDG. REMEDY: IMMEDIATELY ERECT A SIDEWALK SHED/OBTAIN PERMITS. MAKE ALL NECESSARY REPAIRS, #34851636M | Jul 1, 2010 DEFAULT | $0 |
| Jan 18, 2008 | Plumbing Non-Hazardous FAILURE TO MAINTAIN PLUMBING AND/OR APPURTENANCES. UPON PHYSICAL INSPECTION FOUND GAS PIPING IN BASEMENT TO LAUNDRY DRYERS NOT PROPERLY SUPPORTED - W/APPROVED SUPPORTS. REMEDY: MAINTAIN PLUMBING & APPURTENANCES #34610317H | Feb 4, 2010 IN VIOLATION | $0 |
| Jan 18, 2008 | Plumbing Non-Hazardous PLUMBING FIXTURE NOT PROPERTY TRAPED OR VENTED UPON PHYSICAL INSPENCTION FOUND SLOP SINK FOR WASTING MACHINES NOT HAVING A VENT TO THE BLDG VENTIZITION SYSTEM. REMEDY: PROPERTY TRAP OR VENT FIXTURE. #34610318J | Oct 1, 2009 IN VIOLATION | $0 |
| Jan 18, 2008 | Plumbing Non-Hazardous FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED. UPON PHYSICAL INSPECTION FOUND NO SPRINKLERS IN BASEMENT LAUNDRY ROOM FOR 2 DRYERS WHERE REQUIRED. REMEDY: PROVIDE AUTOMATIC SPRINKLERS. #34610316X | Oct 1, 2009 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00766 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00765 | DOB VIOLATION - ACTIVE |
| Feb 16, 2023 | HAZARDOUS CONDITION (FACADE) CYCLE 9C UNSAFE REPORT FILED #910757 | DOB VIOLATION - ACTIVE |
| Dec 29, 2022 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO SEVERELY CRACKED/DISPLACED BRICKWORK, DETERIORATED/LOOSE MORTAR JOINTS,DISPLACED DECORATIVE STONE,RUSTED/ SAGGING LINTELS & CRACKED/BOWED/LEANING PARAPET WALL ON ALL EXPOSURES REMEDY:IMMED TAKE ACTION AND PROVIDE SAFETY MEASURES TO SECURE AND PROTECT THE PUBLIC AND INSTAL #FA11201JP | DOB VIOLATION - ACTIVE |
| Dec 1, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2101214 | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2001564 | DOB VIOLATION - ACTIVE |
| Sep 2, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #01450 | DOB VIOLATION - ACTIVE |
| Sep 2, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #01449 | DOB VIOLATION - ACTIVE |
| Jan 18, 2008 | PLUMBING #12RL09 | DOB VIOLATION - ACTIVE |
| Jan 18, 2008 | PLUMBING #L12RL10 | DOB VIOLATION - ACTIVE |
| Jan 18, 2008 | PLUMBING #L12RL08 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 8, 2026 | GHG Emissions - LL97 FTF-EN-LL97321 FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Jun 24, 2026 | GHG Emissions - LL97 FTF-EN-LL97321 | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Feb 16, 2023 | Facades FISPHAZ CYCLE 9C UNSAFE REPORT FILED | Active |
| Dec 1, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Sep 2, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 2, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 30, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 14, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR LATCH , 1st STORY | Sep 28, 2026 |
| Sep 11, 2026 | B | Apt 5B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Oct 16, 2026 |
| Sep 11, 2026 | B | Apt 5B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET SEAL AT REFERIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Oct 16, 2026 |
| Sep 11, 2026 | B | Apt 5B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Oct 16, 2026 |
| Sep 11, 2026 | B | Apt 5B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Oct 16, 2026 |
| Sep 10, 2026 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY | Dec 14, 2026 |
| Apr 28, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BOILER ROOM DOOR AT BASEMENT | May 12, 2026 |
| Mar 30, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 3rd STORY | Apr 25, 2026 |
| Mar 30, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 2nd STORY | Apr 25, 2026 |
| Mar 30, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 5th STORY | Apr 25, 2026 |
| Mar 30, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 1st STORY | Apr 25, 2026 |
| Mar 30, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 6th STORY | Apr 25, 2026 |
| Mar 30, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 4th STORY | Apr 25, 2026 |
| Mar 25, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Apr 20, 2026 |
| Mar 25, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT BASEMENT | Apr 20, 2026 |
| Jan 14, 2026 | B | Apt 2G · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 18, 2026 |
| Jan 14, 2026 | B | Apt 2G · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 18, 2026 |
| Oct 8, 2025 | B | Apt 1F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17974557 ISSUED 09-JUN-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017. | Nov 12, 2025 |
| Oct 7, 2025 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT BASEMENT | Nov 2, 2025 |
| Oct 7, 2025 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT STORAGE ROOM | Nov 2, 2025 |
| Jun 11, 2025 | A | Apt 1F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 14, 2025 |
| Jun 11, 2025 | A | Apt 1F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 5th ROOM FROM NORTH, THE PRIVATE HALLWAY LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 14, 2025 |
| Jun 11, 2025 | C | Apt 1F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM | Jul 5, 2025 |
| Jun 11, 2025 | C | Apt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR PLASTER AT NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 17, 2025 |
| Jun 10, 2025 | B | Apt 1F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNICATION SYSTEM FROM BUILDING ENTRANCE TO PANEL AT WEST WALL IN THE FOYER LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 15, 2025 |
| Jun 10, 2025 | C | Apt 1F · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APAR | Jul 6, 2025 |
| Dec 23, 2024 | B | Apt 6D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 27, 2025 |
| Dec 23, 2024 | A | Apt 6D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 28, 2025 |
| Dec 2, 2024 | B | Apt 6D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 6, 2025 |
| Nov 29, 2024 | B | Apt 1F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 3, 2025 |
| Nov 29, 2024 | B | Apt 1F · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE DEVICE INSTALLED AT DOOR LEADING TO ROOM WITH THE FIRE ESCAPE IN THE 5th ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 3, 2025 |
| Nov 29, 2024 | B | Apt 1F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 3, 2025 |
| Aug 21, 2024 | B | Apt 2D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX. 5 (SQFT) AND WEST WALL APPROX. 3 (SQFT) IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16923329 ISSUED 19-APR-24 HAS BEEN UPGRADED TO CLASS B PER | Sep 25, 2024 |
| Jan 17, 2023 | C | Apt 1F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 12, 2023 |
| Jun 13, 2022 | A | Apt 1D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM VESTIBULE TO WEST WALL IN THE FOYER LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 16, 2022 |
| May 9, 2022 | A | Apt 1D · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DRYWALL PARTITION WALL ERECTED FROM FLOOR TO CEILING SUBDIVIDING ROOM AND DIMINISHING LIGHT IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1D, 1 | Aug 12, 2022 |
| Nov 20, 2020 | B | Apt 1D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM BUILDING ENTRANCE TO RETURN PANEL AT WEST WALL IN THE FOYER LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Dec 25, 2020 |
| Sep 23, 2019 | B | Apt 2D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 28, 2019 |
| May 8, 2018 | B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT THE REAR YARD. | Jun 12, 2018 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 8, 2026 | DOB Safety | GHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Open |
| Oct 5, 2026 | ECB | Construction: FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39161647L ISSUED ON 09-25-2025 FOR TAMPERED WITH, REMOVED OR DEFACED A WRITTEN POSTED STOP WORK ORDER.( NO STICKER FOUND ), FILE A CERTIFICATE OF CORREC | Open |
| Oct 5, 2026 | ECB | Construction: AT TIME OF INSPECTION NO OBSTRUCTION AT EXPOSURE # 4 HOWEVER FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39086235H ISSUED ON 05-11-2023 FOR FAILURE TO PROVIDE AN UNOBSTRUCTED EXIT PASSAGEWAY., FIL | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 14, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR LATCH , 1st STORY | Open |
| Sep 11, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Open |
| Sep 11, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET SEAL AT REFERIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Open |
| Sep 11, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Open |
| Sep 11, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM WEST AT NORTH | Open |
| Sep 10, 2026 | HPD A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)