Queens · Block 15704 · Lot 5 · 11691

20-08 Cornaga Avenue

2 floors · 1 apartments · 2,800 sq ft · built 1931 · class S1 · owner of record: Beach Cornaga Llc

32open violations
$73,594ECB/OATH penalties owed
7HPD class C (immediately hazardous)
427dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 306 days
Required only if the owner doesn't live there
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 427 days
Next cycle year 2027

Open violations

ECB / OATH (7) · $73,594 owed
IssuedViolationHearingBalance
Jan 28, 2026Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VI023-00260/012823CER01J DATED 01-28-2023. RESPONDED WAS REQUIRE TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS
#39175168L
Jun 8, 2027
DEFAULT
$25,000
Jan 28, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR SUMMONS 39078611M, FILE A CERTIFICATE OF CORRECTION
#39175169N
Jun 8, 2027
DEFAULT
$6,250
Jan 28, 2026Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. FAILURE TO OBTAIN PERMITS OR FILE CERTIFICATE OF CORRECTIONS FOR SUMMONS 39078610K, COMPLY WITH COMMISSIONER'S ORDER
#39175167J
Jun 8, 2027
DEFAULT
$12,500
Oct 11, 2023Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-00260/012823CE01J, DATED 1/28/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDIITONS. AS
#37025788X
Oct 22, 2024
IN VIOLATION
$2,500
Jan 28, 2023Construction CLASS - 1
AFTER BEING CALLED TO SITE BY FDNY I NOTED ON 1ST FL SEVERAL LOAD BEARING WALLS REMOVED, BOILER WORK, GAS WORK, AND FIRE RATED PARTITIONS REMOVED EFFECTING STRUCTURE. ALSO KITCHEN AND BATHROOM ADDED 2ND FLOOR.
#39078610K
May 2, 2023
DEFAULT
$25,060
Jan 28, 2023Construction CLASS - 1
RESPONDING TO CALL BY FDNY NOTED HOLES IN FLOOR, EXPOSED DUCT WORK, EXPOSED BOILER, EXPOSED GAS LINE (1ST FLOOR), EXPOSED ELECTRICAL THROUGHOUT, HOLES IN HALL CIELING, AND SLOPING STAIRCASE IN HALLWAY 2ND FLOOR
#39078611M
May 2, 2023
DEFAULT
$2,284
Jun 6, 2017Construction CLASS - 2
WORK WITHOUT A PERMIT NOTED:CONSTRUCTED 2ND FLR EXTENSION WITH FULL HEIGHT PARTITIONS NEW PLYWOOD SUB FLR ELECTRICAL AND PLUMBING WORK:NO FILING IN DOB RECORDS.STOP ALL WORK FULL SWO ISSUED.REM:OBTAIN PERMIT OR
#35257259K
Sep 19, 2017
IN VIOLATION
$0
DOB (4)
IssuedViolationStatus
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#02304
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#02305
DOB VIOLATION - ACTIVE
Jan 28, 2023CONSTRUCTION
NOTED BEARING WALLS ADDED AND REMOVED AT 1ST FLOOR. ALSO STAIR CASE SLOPING, STEEL BEAMS ADDED, AND UNSUPPORTED JOISTS IN 1ST FLOOR CEILING.
#23-00260
DOB VIOLATION - ACTIVE
Jun 8, 2011BOILER

#TEMP-01
VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Jan 17, 2020Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
HPD (18) · C 7 · B 11 · A 0
IssuedClassViolationCorrect by
Jun 10, 2008BSECTION 27-2038 ADMIN CODE: PROVIDE ADEQUATE LIGHTING FOR 1ST STY. SHARED HALL FRONT 60 WATTS MIN. REQUIREDJul 15, 2008
Jun 10, 2008CSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE DISCONNETED COPPER HEAT PIPES FROM BOILER TO 1 STY APT E\R.Jun 16, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD PANELED WALLS OF 1 STY APT BATHROOM.Jul 15, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CELOTEX TYPE CEILING 1 STY APT FRONT ROOM.Jul 15, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC WALL LIGHT FIXTURE 1 STY BOILER ROOM.Jul 15, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT 1 STY PUBLIC HALL.Jul 15, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CEILING OF 1 STY PUBLIC HALL OVER BOXES.Jul 15, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILINGS ALL ROOMS 2ND STY. APT. 2Jul 15, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER BATHROOM AND PRIVATE HALL 2ND STY. APT. 2 D32411HJul 15, 2008
Jun 10, 2008BSECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES AND EXTENSION CORDS 2ND STY. SHARED HALLJul 15, 2008
Jun 10, 2008BSECTION 27-2032, 2034 ADNIM. CODE: DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM HOT WATER HEATER BATHROOM 2ND STY. APT. 2Jul 15, 2008
Jun 10, 2008BSECTION 27-2038 ADMIN CODE: PROVIDE ADEQUATE LIGHTING FOR 1ST AND 2ND STY. PUBLIC HALLS - ( ER - 1 )Jul 15, 2008
Jun 10, 2008CSECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES BATHROOM AND KITCHEN - 2ND STY. APT.Jun 16, 2008
Jun 10, 2008CSECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2 STY. APT 2C KITCHEN AND BATHROOM.Jun 16, 2008
Jun 10, 2008CSECTION 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES 2 STY. APT 2C KITCHEN AND BATHROOM.Jun 16, 2008
Jun 10, 2008CSECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING 2 STY. 2C APT. FRONT ROOM - ER - 1.Jun 16, 2008
Jun 10, 2008CSECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING 2 STY. APT 2 C - CENTER ROOM.Jun 16, 2008
Jul 3, 2006CSECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES BATHROOM AND KITCHEN 2ND STORY APARTMENT # 2.Sep 10, 2006

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 9:49 PM ET. BBL 4157040005.