Manhattan · Block 202 · Lot 7501 · 10013

2 Elizabeth Street

8 floors · 167 apartments · 176,254 sq ft · built 1985 · class R4 · owner of record: Bridgeview House Condominium

92open violations
$52,075ECB/OATH penalties owed
4HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 59 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 59 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-03-26 (Accepted). Agency page

Dec 31, 2026
in 59 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 75 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 176,254 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 180 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 180 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 790 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $733,760 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 842 days
Filing window not open yet
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 202). Agency page

Dec 31, 2032
in 2251 days
Next due 2032

Open violations

ECB / OATH (27) · $52,075 owed
IssuedViolationHearingBalance
Sep 23, 2026Construction CLASS - 2
NOTE: AT TIME OF INSPECTION OF A SIDEWALK SHED IN PLACE AT EXPO# 1-2-3, I OBSERVED THAT THE VERTICAL MEMBER LOCATED AT THE DRIVEWAY AT EXPO# 1-3 WAS MISSING HIGH VISIBILITY MARKING AND WAS NOT PROTECTED AGAINST
#39559505X
Dec 3, 2026
PENDING
$2,400
May 12, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH BC 3307.6.5.6 SHARP EDGES, SIDEWALK SHED VERTICAL ELEMENTS HAVE SHAPE EDGES IN SEVERAL LOCATIONS BY PEDESTRIAN'S PASSAGEWAY. BOLTS WITHOUT A CAP CREATE HAZARDS FOR PEDESTRIANS USING THE A
#39554028J
Mar 22, 2027
$2,400
Feb 4, 2026Construction CLASS - 1
NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK WITHOUT PERMIT VIOLATION #39086163H ISSUED 5/12/2023. SPRAY-ON FIRESTOPPING REMAINS INSTALLED AT THE SUB-CELLAR GARAGE CEILING IN CONJUNCTION WITH TEMPORARY
#39176056L
May 14, 2026
IN VIOLATION
$2,500
Feb 4, 2026Construction CLASS - 1
ACCESS GAINED, VIOLATING CONDITIONS STILL EXIST FOR VIOLATION #39084937N ISSUED 4/25/2023. CERTIFICATE OF OCCUPANCY #059649 PERMITS 46 PASSENGER VEHICLES IN THE CELLAR AND 70 IN THE SUB-CELLAR. AT TIME OF INSPE
#39176052Y
Jan 11, 2027
PENDING
$6,250
Feb 4, 2026Construction CLASS - 1
AGGRAVATED CONDITIONS OBSERVED, CONSISTENT WITH VIOLATIONS #39084643H AND #37025667J (ENGINEER'S REPORT REQUEST). AT THE OCCUPIED PARKING GARAGE CELLAR AND SUB-CELLAR LEVELS, OBSERVED RUSTED STRUCTURAL STEEL BE
#39176046H
Jan 11, 2027
PENDING
$6,250
Feb 4, 2026Construction CLASS - 1
CERTIFICATE OF CORRECTION HAS NOT BEEN SUBMITTED FOR CLASS 1 VIOLATION #37025667J ISSUED 10/11/2023 FOR FAILURE TO SUBMIT THE ENGINEER'S REPORT REQUESTED UNDER DOB VIOLATION #23-01167 DATED 4/25/2023. THE VIOLA
#39176030N
May 14, 2026
IN VIOLATION
$2,500
Feb 4, 2026Construction CLASS - 2
ACCESS GAINED. VIOLATING CONDITIONS ARE NO LONGER PRESENT. HOWEVER, A CERTIFICATE OF CORRECTION HAS NOT BEEN SUBMITTED FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39053752P ISSUED 1/4/2022 FOR MISSING MORTAR JOI
#39176034K
May 14, 2026
IN VIOLATION
$1,250
Feb 4, 2026Construction CLASS - 1
NO ACCESS GAINED. NO CERTIFICATE OF CORRECTION ON FILE AS PER COMMISSIONER'S REQUEST FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #3913533N ISSUED 7/14/2025, CITING ELECTRICAL WORK OBSERVED INCLUDING INSTALLATION
#39176055J
May 14, 2026
IN VIOLATION
$2,500
Aug 21, 2025Construction CLASS - 2
FAILURE TO MAINTAIN SIDEWALK SHED. AT EXPOSURE 4 BY THE GARAGE ENTRANCE OBSERVED DAMAGE HORIZONTAL BRACES AND VERTICAL MEMBERS BEEN DISLOCATED ADDITIONALLY NO SIGNS ON VERTICAL MEMBERS FOR VISIBILITY AT THE DRI
#39543936L
Oct 30, 2025
PENDING
$2,400
Jul 14, 2025Construction CLASS - 1
OBSERVED WORK BEING PERFORMED WITH INSUFICENT BARRIERS OF PROTECTION AND NOTICED OF WORK BEING PERFORMED DURING REGULAR BUISNESS OPERATIONS WITHOUT PROPER WORK PROTECTION FROM DUST, CONSTRUCTION DEBRIS, AND WOR
#39153554M
Apr 2, 2026
DEFAULT
$3,750
Jul 14, 2025Unknown CLASS - 1
AT TIME OF INSPECTION, GAINED ACCESS TO LOCATION. OBSERVED WORK BEING PERFORMED, (NSTALLATION OF ATM, EXPOSED WIRES, AND BX CABLES) INSTALLED WITHOUT PERMITS LOCATED AT FIRST/GROUND LEVEL COMMERCIAL SPACE AND C
#39153533N
Sep 18, 2025
DEFAULT
$8,000
Jul 14, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED WORK BEING DONE UNDER JOB# M01173182, NO MEANS AND METHODS FILED UNDER TPP.; 28-201-1, COMPLY WITH CODE
#39153553K
Apr 2, 2026
DEFAULT
$3,750
Apr 18, 2024Boilers CLASS - 2
AS PER ONE FEDERAL BOILER FST-300. SERIAL NO. 9705. FAILURE TO SIGN-OFF PERMIT NO. M00830624 FOR A DUAL FUEL BURNER. CORRECT VIOLATING CONDITIONS. REGISTER BURNER.
#39112001L
Aug 1, 2024
IN VIOLATION
$625
Feb 9, 2024Construction CLASS - 1
FAILURE TO TAKE/PROVIDE REQUIRED ACTION TO SECURE PUBLIC SAFETY AT A DESIGNATED UNSAFE BUILDING FACADE AS PER TECHNICAL REPORT #"UNSAFE-900453-9L-001" ISSUE DATE" 02/05/2024". NOTE:-ACCORDING TO Q.E.W.I'S FILIN
#35679961K
Aug 15, 2024
IN VIOLATION
$0
Dec 21, 2023Construction CLASS - 2
WORK WITHOUT A PERMIT. FULL HEIGHT PARTITIONS FROM FLOOR TO CEILING ERECTED IN APT #3P TO CONVERT LIVING ROOM OF LEGAL (1) BEDROOM UNIT TO (2) ADDITIONAL BEDROOMS. APT #3P IS NOW ARRANGED AS (3) BEDROOM UNIT WI
#39102076R
Mar 21, 2024
DEFAULT
$6,250
Oct 11, 2023Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01167, DATED 4/25/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11/2023,
#37025667J
Jun 6, 2024
IN VIOLATION
$0
May 12, 2023Construction CLASS - 1
AT TIME OF INSPECTION, SPRAY ON FIRESTOPPING INSTALLED AT CEILING AT GARAGE AT SUB CELLAR OF PREMISES IN CONJUNCTION WITH TEMPORARY SHORING WORK UNDER DOB EMERGENCY WORK ORDER #042623CFEU10301BS - SAID WORK WAS
#39086163H
Jan 4, 2024
IN VIOLATION
$0
Apr 25, 2023Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED AT THE OCCUPIED PARKING GARAGE STRUCTURE, CELLAR & SUB CELLAR LEVELS: RUSTED & DETERIORATED STRUCTURAL STEEL BEAMS AT MULTIPLE LOCATIONS. VERTIC
#39084643H
Jun 29, 2023
IN VIOLATION
$0
Apr 25, 2023Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR DOB RECORDS. CO 059649 INDICATES CELLAR LEVEL USE FOR 46 PASSENGER VEHICLES & SUB-CELLAR LEVEL FOR 70 VEHICLES. AT TIME OF INSPECTION OBSERV
#39084937N
Jul 25, 2024
IN VIOLATION
$0
Apr 25, 2023Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTION OBSERVED AT PARKING GARAGE SUB CELLAR LEVEL ACCESS TO EXIT STAIRWELL AT CENTER OF THE LEVEL OBSTRUCTED BY A PARKED VEHICLE DIRECTLY IN THE
#39084939R
Jun 20, 2024
IN VIOLATION
$1,250
Jan 4, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED A HORIZONTAL CRACK TO THE MORTAR JOINT/MISSING MORTAR ALONG THE LINTEL OF THE 8TH FLOOR WINDOWS TO THE LEFT AT EXPOSURE #
#39053752P
Nov 3, 2022
IN VIOLATION
$0
Dec 11, 2015Local Law CLASS - 2
FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW FISP REPORT. RMDY: FILE AN AMENDED REPORT FOLLOWING REMEDIAL REP
#36023624Y
Oct 6, 2016
ADMIT/IN-VIO
$0
Jul 30, 2013Construction CLASS - 2
FAIL TO MAINTAIN EXTERIOR BLDG.NOTE:SOUTH ELEVATION, EXP #1:OBSERVE SWELLING,DETERIORATING FAILURE IN SHELF ANGLES & PARAPET FACADE;BENDING & DETERIORATING IN LINTEL FACADE,EAST ELEVATION,EXP #4 OBSERVE DETERIO
#35002028Z
Sep 19, 2013
IN VIOLATION
$0
Jan 14, 2012Construction CLASS - 1
FAILURE TO MAINTAIN NOTE: PARKING GARAGE HAS LOOSE SECTIONS OF CONCRETE @ CEILING OF STAIRWELL B FROM LEVEL"B TO C" & EXPOSED REBAR W/SPALLING CONCRETE IN VARIOUS AREAS OF CEILING OF GARAGE. REMEDY MAINTAIN &
#34921024M
Jun 14, 2012
WRITTEN OFF
$0
Nov 3, 2011Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. 1-EXIT DOOR TO STAIRWELLS, NOT SELF CLOSING THROUGHOUT; MISSING DOOR AT CELLAR -HOLD OPEN. 2-EXIT DOOR "PULL HERE TO OPEN ALARM WILL SOUND" HARDWARE NOT FU
#34933984H
Feb 23, 2012
IN VIOLATION
$0
Nov 3, 2011Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER:ILLUMINATION FOR EXITS DISCHARGES & PATHWAY BC1006.1;27-381.EXIT LIGHT FIXTURES NOT ILLUMINATED SUB-BSMNT @ C-1,S STAIR.EMERGENCY BATTERY PACK/HARDWIRED NOT FUN
#34933982Y
Feb 23, 2012
IN VIOLATION
$0
Nov 3, 2011Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.SUB-CELLAR(COL C-1)CEILING CONCRETE BROKEN & CRACKED EXPOSING REBAR-RUSTING WIRE MESH & REBAR(COVERED BY BLUE TARP).SUB CELLAR-STAIR C(LAND B GOING TO C)CEILING
#34933983X
Feb 23, 2012
IN VIOLATION
$0
DOB (18)
IssuedViolationStatus
Apr 13, 2026CONSTRUCTION
FTM, INSPECT & REPORT PS: PARKING STRUCTURE W/PSID#M02413 OCCUPIES 1FL,CEL & SUBCEL OF BLDG.PVO ORDINALLY ISSUED ON 4/26/23 DUE TO UNSAFE CONDITIONS IN PS.PIPS REPORT FILING DEADLING WAS 12/31/2023. AS OF 4/13/26,NO PIPS REPORT SUBMITTED.REMEDY:IMMED EVAL ENTIRE PS & SUBMIT PIPS REPORT BY 5/15/26.IM
#PS10301BS
DOB VIOLATION - ACTIVE
Jan 13, 2026CONSTRUCTION
FTM, INSPECT & REPORT PARKING STRUCTURE:PSID#M002413 OCCUPIES PORTIONS OF 1FL, CELLAR & SUB-CELLAR OF BLDG. PVO ISSUED ON 2/26/23 DUE TO UN SAFE CONDITIONS IN PARKING STRUCTURE.REPORT FILING DEADLING WAS 12/31/23.REMEDY:IMMED EVAL ENTIRE PS,SUBMIT REPORT.FILE PIPS REPORT BY 5/13/2026.IMPLEMENT REPAI
#PS10301BS
DOB VIOLATION - ACTIVE
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00015
DOB VIOLATION - ACTIVE
Jul 29, 2024FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
CYCLE 9C FAILURE TO CORRECT SWARMP CONDITIONS
#00667
DOB VIOLATION - ACTIVE
May 1, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00003
DOB VIOLATION - ACTIVE
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#01606
DOB VIOLATION - ACTIVE
Jan 5, 2024CONSTRUCTION
FTM.SEVERELY DETERIORATD STEEL&MISSNG STEEL BEAM OBSERVEDON WEST SIDE OF CELLAR LVL FRAMNG,WHICH SUPPORTS EGRESS STAIR FOR SUB-CELLAR LVL OF GARAGE&EGRESS FOR CELLAR LVL&SUNKEN.1.IMMED INSTALL ADD TEMP SHORNG W/IN2 BUSINESS DAYS OF WRK STRT
#FEU10301BS
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00036
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00035
DOB VIOLATION - ACTIVE
May 15, 2023CONSTRUCTION
EMERGENCY WORK-METAL DECK TOP OF STEEL BEAMS&PLYWOOD INSTLDBETWN STEEL BEAMS BOTTOM FACADES WATER DMGD&SEVERLY DETERIORATED@REARUNDR SIDWLK BOWERY&OVER PARK GARG RAMP FROM CELLARE TO SUBCELLAR LEVELS.IMMED REMV ALL DETERIORATD METAL DRYWL&PLYWOD INSTL NEW TEMP PROTCTN&TEMP BEAMS ALL WRK DIRECTLY SUP
#FEU10301BS
DOB VIOLATION - ACTIVE
Apr 26, 2023CONSTRUCTION
FTM.CONCRETE ENCASEMENT WAS REMOVED FROM BEAMS&GIRDERS@1STFL&CELLAR LVLS&REPLACED W/SPRAY ON FIREPROOFNG,COMPROMISING INTEGRITY OFDRAPED MESH SLAB SYSTEM.BEAM REINFORCEMENT INSTALLD@CELLAR BEAMS.1.NYS PE STRCTRL ENGNEER&IMMED EVAL ALL CNDTNS VISIBLE IN PRKNG GARAGE&DSIGN REPAIRS&LEGALIZATN DRWNGS,2.
#FEU10303BS
DOB VIOLATION - ACTIVE
Apr 26, 2023CONSTRUCTION
EMER WORK.STRCTRE OVER PRKNG GARAGE AREA IN STATE OF DISREPAIR/MISSING FIREPROOFNG,SPALLING SLABS,CORROSION@STEEL FRAMNG,&DETERIORATD/CRACKD BRCK MASONRY IN MULT LOCTNS.SVRLY CORRODED STEEL BEAMS OBSRVD.1.NYS PE TO IMMED EVAL ENT PRKNG GARAGE AREA&DOB REGSTRD CNTRTCR TO IMMED INSTLL TEMP SHRING@DREC
#FEU10301BS
DOB VIOLATION - ACTIVE
Apr 26, 2023CONSTRUCTION
FTM.STRCTRE IN&ABOVE PRKNG GARAGE AREA IN STATE OF DISREPAIR W/MISSING FIREPROOFNG,SPALLING SLABS,CORRODED STEEL FRAMNG,&DTERIORATD MISSING/ CRCKD BRCK,CMU,&CONCRETE WALLS IN MULT LOCTNS.SVRLY CORRODED.1.NYS PE STRCTRE ENGNEER TO IMMED EVAL ENT PRKNG GARAGE AREA&ENT CELLAR LVL OF BLDG&DESIGN REPAIRS
#FEU10302BS
DOB VIOLATION - ACTIVE
Apr 25, 2023CONSTRUCTION
OBSERVED AT THE OCCUPIED PARKING GARAGE STRUCTURE, CELLAR & SUB CELLAR LEVELS: RUSTED & DETERIORATED STRUCTURAL STEEL BEAMS AT MULTIPLE LOCATIONS. VERTICAL & STEP CRACKS IN CMU WALL AT VARIOUS LOCATIONS. BROKEN/MISSING BRICK& CMU SEVERAL DIFFERENT LOCATIONS. EVIDENCE OF WATER PENETRATION DAMAGE AT A
#23-01167
DOB VIOLATION - ACTIVE
Mar 30, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00003
DOB VIOLATION - ACTIVE
May 29, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00002
DOB VIOLATION - ACTIVE
Feb 19, 2019FACADE SAFETY PROGRAM

#HAZ87861
DOB VIOLATION - ACTIVE
Aug 17, 2006CONSTRUCTION

#03CW01
DOB VIOLATION - ACTIVE
DOB NOW Safety (15)
IssuedViolationStatus
Oct 28, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 28, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 18, 2026Parking Structures FTC-PS-UNSAFE
202606
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Nov 25, 2024Parking Structures FTF-PS-INITL
Failure to file sub cycle 1A compliance report by 12/31/2023
Active
Oct 11, 2024Elevators FTC-VT-CAT1-NJ
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Jul 29, 2024Facades FISPFCS
CYCLE 9C FAILURE TO CORRECT SWARMP CONDITIONS
Active
May 1, 2024AEUHAZ FTC-AEU-HAZ
Active
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Mar 30, 2022AEUHAZ FTC-AEU-HAZ
Active
May 29, 2019AEUHAZ FTC-AEU-HAZ
Active
Feb 19, 2019Facades FISP
CYCLE 8C UNSAFE REPORT FILED
Active
HPD (36) · C 4 · B 19 · A 13
IssuedClassViolationCorrect by
Sep 14, 2026A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSINGDec 18, 2026
Sep 14, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMADec 18, 2026
Sep 14, 2026A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING AT PUBLIC HALL, 1st STORYDec 18, 2026
Sep 14, 2026A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYDec 18, 2026
Sep 14, 2026A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYDec 18, 2026
Sep 14, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYDec 18, 2026
May 26, 2026BApt 5S · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTHJun 30, 2026
May 26, 2026CApt 5S · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTHJun 21, 2026
May 26, 2026CApt 5S · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTHJun 21, 2026
May 26, 2026BApt 5S · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTHJun 30, 2026
Feb 11, 2026BApt 7A · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 3rd APARTMENT FROM WEST AT NORTHMar 18, 2026
Feb 11, 2026BApt 7A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 3rd APARTMENT FROM WEST AT NORTHMar 18, 2026
Feb 11, 2026CApt 7A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 7A, 7th STORY, 3rd APARTMENT FROM WEST AT NORTHFeb 25, 2026
Oct 30, 2025BApt 8P · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 8P, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTIDec 4, 2025
Oct 30, 2025BApt 8P · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 8P, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECDec 4, 2025
Aug 15, 2025BApt 6W · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6W, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SSep 19, 2025
Aug 15, 2025BApt 6W · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6W, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTISep 19, 2025
Aug 15, 2025CApt 6W · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 6W, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST''Aug 29, 2025
Aug 15, 2025BApt 6W · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6W, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST''Sep 19, 2025
Aug 15, 2025BApt 6W · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6W, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST''Sep 19, 2025
May 17, 2024BApt 3L · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''A-M''Jun 21, 2024
May 17, 2024B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCHSET AT FIRE DOOR LEADING TO STAIRCASE A AT PUBLIC HALL STAIRS, 3rd STORYJun 21, 2024
May 17, 2024BApt 3L · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''A-M''Jun 21, 2024
May 17, 2024BApt 3L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''A-M''Jun 21, 2024
May 17, 2024BApt 3L · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''A-M''Jun 21, 2024
Jan 29, 2024A§ 27-2098 ADM CODE FILE WITH THIS DEPARTMENT A REGISTRATION STATEMENT FOR BUILDING.May 3, 2024
Jul 15, 2020A§ 27-2049 ADM CODE POST AND MAINTAIN A STREET NUMBER ON THE FRONT OF THE DWELLING PLAINLY VISIBLE FROM THE SIDEWALK.Oct 18, 2020
Dec 28, 2018AApt 7D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 7D, 7th STORY, 1st APARTMENT FROM WEST AT NORTHApr 2, 2019
Dec 28, 2018AApt 7D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 7D, 7th STORY, 1st APARTMENT FROM WEST AT NORTHApr 2, 2019
Dec 28, 2018AApt 7D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 7D, 7th STORY, 1st APARTMENT FROM WEST AT NORTHApr 2, 2019
Dec 28, 2018AApt 7D · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 7D, 7th STORY, 1st APARTMENT FROM WEST AT NORTHApr 2, 2019
Dec 28, 2018BApt 7D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 7D, 7th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 1, 2019
Jun 11, 2014AApt 7J · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN LOCATED AT APT 7J, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 14, 2014
Jun 11, 2014BApt 7J · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 7J, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 16, 2014
Aug 18, 2009BApt 4F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS COLD WATER 4 STY 2 FROM NORTHWEST APT 4F KITCHEN. , SECTION '' ''Sep 22, 2009
Aug 18, 2009BApt 4F · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD TILE FLOOR 4 STY 2 FROM NORTHWEST APT 4F PRIVATE HALL. , SECTION '' ''Sep 22, 2009

Issued in the last 120 days

DateSourceWhatNow
Oct 28, 2026DOB SafetyAEUHAZ: Open
Oct 28, 2026DOB SafetyAEUHAZ: Open
Sep 23, 2026ECBConstruction: NOTE: AT TIME OF INSPECTION OF A SIDEWALK SHED IN PLACE AT EXPO# 1-2-3, I OBSERVED THAT THE VERTICAL MEMBER LOCATED AT THE DRIVEWAY AT EXPO# 1-3 WAS MISSING HIGH VISIBILITY MARKING AND WAS NOT PROTECTED AGAINSTOpen
Sep 14, 2026HPD A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSINGOpen
Sep 14, 2026HPD A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAOpen
Sep 14, 2026HPD A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)