7 floors · 66 apartments · 57,356 sq ft · built 2005 · class R4 · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-28 (Accepted). Agency page | Dec 31, 2026 in 61 days | 3 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 57,356 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 182 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 182 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 426 days | Next cycle year 2027 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $284,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 844 days | Filing window not open yet |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 16113). Agency page | Dec 31, 2033 in 2618 days | Next due 2033 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 17, 2026 | Construction CLASS - 1 RESPONDING TO AN INCIDENT REPORTED BY FDNY THAT WIND BLOW SUSPENDED SCAFFOLD OUT RIGGER OUT OF PLACE LEANING IT IN DANGER OF FALLING, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT THERE WERE NO NOTIFICATI #39551908Y | May 27, 2027 DEFAULT | $25,000 |
| Mar 17, 2026 | Construction CLASS - 2 RESPONDING TO AN INCIDENT REPORTED BY FDNY THAT WIND BLOW SUSPENDED SCAFFOLD OUT RIGGER OUT OF PLACE LEANING IT IN DANGER OF FALLING, INVESTIGATION REVEAL THAT THE SCAFFOLD WAS NOT INSPECTED, THE LAST WORKING D #39551907M | May 27, 2027 DEFAULT | $10,000 |
| Jun 16, 2025 | Construction CLASS - 2 DURING INSPECTION OF A SIDEWALK SHED IN PLACE, I OBSERVED THAT THERE WERE SUSPENDED SCAFFOLDS, PAILS, LARGE QUANTITY OF BLACK BAGS AND OTHER CONSTRUCTION RELATED MATERIAL STORED ON TOP THE SHED, WHICH BY CODE A #39541455L | Aug 26, 2025 DEFAULT | $10,000 |
| Apr 19, 2024 | Cranes and Derricks CLASS - 2 AT TIME OF INSPECTION OF A 7 STORY BUILDING I OBSERVED 2 SUSPENDED SCAFFOLDING IN PLACE, DOB RECORDS REVEALED THAT THERE WAS NO NOTIFICATION TO THE DEPARTMENT PRIOR TO THE INSTALL OF THE SUSPENDED SCAFFOLD. NOT #39527843M | Jul 2, 2024 DEFAULT | $10,000 |
| Jan 8, 2024 | Construction CLASS - 2 SIDEWALK SHED. OBSERVE SIDEWALK SHED IN PLACE NOT CONFORM TO DOB SEALED PLANS IN DEPARTMENTS RECORDS WITH SHEDS DECK BRIDGED&CONSTRUCTED ON BUILDINGS EXISTING CANOPIES WITH SHORING POSTS SUPPORTING CANOPY BEAMS #39524580X | Mar 19, 2024 DEFAULT | $6,250 |
| Oct 19, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY28-302.4 FOR CONTROL#813492.AGG1:PRIOR NOV37018480Y UNDER28-302.4 SUB #37023207J | Feb 14, 2023 IN VIOLATION | $0 |
| Feb 13, 2020 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#813492.REM:SUBMIT ACCEPTABLE REQUIRED T #37018480Y | Jun 30, 2020 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 1, 2024 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) FAILURE TO CORRECT SWARMP CONDITIONS #00096 | DOB VIOLATION - ACTIVE |
| Feb 20, 2024 | HAZARDOUS CONDITION (FACADE) CYCLE 9C UNSAFE REPORT FILED #911569 | DOB VIOLATION - ACTIVE |
| Dec 2, 2020 | ELEVATOR #9027/694387 | DOB VIOLATION - ACTIVE |
| Dec 2, 2020 | ELEVATOR #9027/694388 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #07542 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #07543 | DOB VIOLATION - ACTIVE |
| Nov 20, 2018 | ELEVATOR #9027/636859 | DOB VIOLATION - ACTIVE |
| Nov 27, 2017 | ELEVATOR #9027/616604 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 1, 2024 | Facades FISPFCS FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Feb 20, 2024 | Facades FISPHAZ CYCLE 9C UNSAFE REPORT FILED | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| Apr 30, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Mar 12, 2026 | B | Apt 5J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 16, 2026 |
| Mar 12, 2026 | B | Apt 5J · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 16, 2026 |
| Mar 12, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT FIRE DOOR LABELED A LEADING TO FIRE STAIRS AT PUBLIC HALL, 1st STORY, SECTION AT NORTH | Apr 16, 2026 |
| Aug 2, 2023 | B | Apt 3G · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, APARTMENT AT NORTH | Sep 6, 2023 |
| Aug 2, 2023 | B | Apt 3G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, APARTMENT AT NORTH | Sep 6, 2023 |
| Aug 2, 2023 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT PUBLIC HALL, 1st STORY | Nov 5, 2023 |
| Aug 2, 2023 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Nov 5, 2023 |
| Aug 2, 2023 | B | Apt 3G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, APARTMENT AT NORTH | Sep 6, 2023 |
| Aug 2, 2023 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Nov 5, 2023 |
| Aug 2, 2023 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Nov 5, 2023 |
| Aug 2, 2023 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT CENTER SECTION EAST ALL STY AT PUBLIC HALL | Nov 5, 2023 |
| Aug 2, 2023 | C | Apt 7E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 7E, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 8, 2023 |
| Aug 2, 2023 | C | Apt 7E · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 7E, 7th STO | Aug 8, 2023 |
| Aug 2, 2023 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Nov 5, 2023 |
| Aug 2, 2023 | B | Apt 3G · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC TILES EAST WALL IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY | Sep 6, 2023 |
| Aug 2, 2023 | B | Apt 6J · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6J, 6th STORY | Oct 10, 2014 |
| May 22, 2015 | B | Apt 3G · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... SOUTH WALL IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, APARTMENT AT NORTH | Jun 26, 2015 |
| Date | Source | What | Now |
|---|---|---|---|
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)