Brooklyn · Block 3246 · Lot 36 · 11237

199 Stockholm Street

5 floors · 10 apartments · 9,443 sq ft · built 1931 · class CB · owner of record: 199 Stockholm St Llc

21open violations
$1,600ECB/OATH penalties owed
9HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 44 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual

Open violations

ECB / OATH (4) · $1,600 owed
IssuedViolationHearingBalance
Oct 20, 2023Elevators CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION PER 1RCNY 11
#39097548M
Jun 24, 2024
IN VIOLATION
$0
Jul 19, 2023Elevators CLASS - 1
THE ONLY ELEVATOR IN SECTION OF BUILDING OR BUILDING IS OUT-OF-SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDOUS CONDITION AS PER 1RCNY 11-02. RESTORE TO SERVICE IMMEDIATELY
#39090480N
Sep 27, 2023
IN VIOLATION
$0
Aug 28, 2018Construction CLASS - 1
WORK W/O A PERMIT/SPRINKLER SYSTEM. NOTED: INSTALLATION OF FIRE SURPRESSION SYSTEM CONNECTIOINS & SPRINKLER HEAD. NO FILING ON RECORD W/THE DEPT. REMEDY: OBTAIN PERMIT.
#35307024Z
May 20, 2019
IN VIOLATION
$800
Aug 28, 2018Construction CLASS - 1
WORK W/O A PERMIT/MECHANICAL. NOTED: 4 WORKERS EMPLYED BY "CMS MECHANICAL" WERE IN PROCESS OF INSTALLING MECHANICAL SYSTEM THROUGHOUT ALL FLOORS. RUNNING CONDENSING LINES FOR COOLING SYSTEM. NO FILINGS ON RECOR
#35307023R
May 20, 2019
IN VIOLATION
$800
DOB (2)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#23996
DOB VIOLATION - ACTIVE
Nov 29, 2021ELEVATOR

#9027/710764
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (12) · C 9 · B 0 · A 3
IssuedClassViolationCorrect by
May 10, 2010CApt 3R · SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 3R, 3rd Jun 5, 2010
May 10, 2010AApt 3R · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT 1st WINDOW SASH FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTAug 13, 2010
May 10, 2010AApt 3R · SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION , 1st RISER FROM NORTH AT EAST WALL IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTAug 13, 2010
May 10, 2010AApt 3R · SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION , CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTAug 13, 2010
May 10, 2010CApt 3R · SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENTJun 5, 2010
May 10, 2010CApt 3R · SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE Jun 5, 2010
May 25, 1999CApt 3R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT EAST AND WEST WINDOW FRAME KITCHEN DOOR FRAME MOLDING 3 STY EAST APT 3R ER1 32887 , SECTION '' ''Jun 14, 1999
May 25, 1999CApt 3R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT NORTH WALL DOOR FRAME MOLDING 3 STY EAST APT 3R SOUTH ROOM ER1 32887 , SECTION '' ''Jun 14, 1999
May 25, 1999CApt 3R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING CENTER ROOM 3 STY EAST APT 3R ER1 32887 , SECTION '' ''Jun 14, 1999
May 25, 1999CApt 3R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT RADIATOR RISER POLE BATHROOM 3 STY EAST APT 3R GONZALEZ MAGALIE 453 6107 ER132887 , SECTION '' ''Jun 14, 1999
Apr 6, 1999CApt 3R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT SOUTH WALL BATHROOM 3 STY EAST APT 3R ER1 29321 LOCATED AT APT 3RApr 26, 1999
Apr 6, 1999CApt 3R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING 2ND ROOM FROM FRONT 3 STY EAST APT 3R GONZALEZ 453 6107 ER1 29321 LOCATED AT APT 3RApr 26, 1999

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 1:18 PM ET. BBL 3032460036.