5 floors · 17 apartments · 20,500 sq ft · built 1912 · class C7 · owner of record: 1951 Southern Boulevard Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 63 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 63 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 79 days | Annual |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 17, 2018 | Construction CLASS - 2 WORK W/O A PERMIT. NOTED: AT 1ST FL REAR;FULL HEIGHT PARTITION WALL ERECTED CREATED A BATHROOM. WATER & WASTE LINES INSTALLED FOR 2PC BATHROOM(TOILET,SINK). REMEDY: OBTAIN PERMIT. #35376480L | Feb 15, 2019 DEFAULT | $0 |
| Oct 17, 2017 | Construction CLASS - 2 FAILURE TO CONDUCT FINAL INSP. FOR COMPLETED WORK WITHIN 1 YEAR OF PERMIT EXPIRATION. APPLICANT HASN'T FILE FINAL INSP. ALT2 JOB #220161526 WHICH PERMIT EXPIRED 1/17/14 IS COMPLETED & SUBSTANTIALLY CONFORM TO P #35261906J | Apr 13, 2018 DEFAULT | $0 |
| Oct 19, 2016 | Construction CLASS - 2 WORK W/O PERMIT. ON 0CT 19,2016 AT 9AM AT THE ABOVE ADDRESS I OBSERVEDIN APT#2 WORK DONE IN THE BATHROOM. THE WATER LINES FOR THE TUB, AND SINK WERE REMOVED, THE BATHROOM WAS GUTTED.PHOTOS TAKEN.RMDY: OBTAIN #35182586Y | Jan 6, 2017 IN VIOLATION | $0 |
| Mar 10, 2016 | Construction CLASS - 2 FAILURE TO COMPLY W/ THE COMM'S ORDER CONTAINED IN NOV#35160729P ISSUED ON 9/10/15 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1,28-204.4 & 1RCNY 102-01.REM COMPLY W/ THE COMM'S ORDER &/OR FILE A CERT OF #35048917M | Apr 29, 2016 DEFAULT | $0 |
| Sep 10, 2015 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED @ CELLAR LEVELACCESS TO CELLAR DOOR IS NOT SELF CLOSING.@ DOORS INSTALLED DOUBLE CYLINDER LOCKS.@ CELLAR CENTER HAS POWER STRIPS & EXTENSIONS CORDS PLUGGI #35160730M | Feb 12, 2016 IN VIOLATION | $0 |
| Sep 10, 2015 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O.NOTED NYC DOB C OF O #1187 DATED 1/5/1943 INDICATES CELLAR TO BE USED AS BOILER & STORAGE ROOMS.NOW CELLAR USED & OCCUPIED @ THE SOUTH WEST CORNER AS AN OFFICE W #35160728N | Feb 12, 2016 IN VIOLATION | $0 |
| Sep 10, 2015 | Construction CLASS - 1 WORK W/O A PERMIT.NOTED @ CELLAR LEVEL OF PREMISES CORNER OF EXP2 & 3 (SOUTHWEST) ERECTED FULL HEIGHT PARTITIONS TO CREATE A ROOM NOW USED AS AN OFFICE & WAITING ROOM NEAR ENTRANCE TO CELLAR.ALSO PARTITIONS ERE #35160729P | Feb 12, 2016 IN VIOLATION | $0 |
| Sep 4, 2014 | Construction CLASS - 1 WORK W/O A PERMIT.DURING PHYSICAL INSP I OBSERV 1 A.O.SMITH HOT WATER HEATER 1 SINK & 1 TOILET & RELATED GAS WASTE,HOT & COLD WATER LINES INSTALLED IN THE CELLAR W/O A PERMIT.LOCATION IS ROYS RESTAURANT & BAR.R #35066872R | Jan 9, 2015 WRITTEN OFF | $0 |
| Sep 4, 2014 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-345 NOTED: AT CELLAR LEVEL INSTALLED AN MECHANICAL ROOM FOR THE ELECTRICAL METERS & A GAS HOT METER HEATER TANK OBSERVED THE #35074506R | Jan 9, 2015 WRITTEN OFF | $0 |
| Sep 4, 2014 | Plumbing CLASS - 2 USE OR INSTALLED OF PLUMB MATERIALS OR EQUIP WHICH DO NOT COMPLY W/RS16 DURING PHYSICAL INSP I OBSERV 1 SMITH & 1 LAVATORY INSTALLED W/PVC WASTE WATER PIPING PVC PIPING ARE NOT ALLOWED IN(MIL)USE OR COMMERCIAL #35066873Z | Oct 31, 2014 STIPULATION/IN-VIO | $0 |
| Sep 4, 2014 | Construction CLASS - 1 FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.DURING PHYSICAL INSP O OBSERV 1 A.D.SMITH HOT WATER FLUE PIPING TERMINATING INSIDE THE CELLARINSTEAD OF CONNECTING TO A CHIMNEY LEADING TO THE ROOF.REM:REPAIR & RE #35066874K | Jan 9, 2015 WRITTEN OFF | $0 |
| Sep 4, 2014 | Construction CLASS - 2 WORK W/O A PERMIT. WORK NOTED: AT CELLAR LEVEL CREATED FULL PARTITION WALLS FOR 4 ROOM W/WINDOWS & DOORS. INSTALLED AN MECHANICAL ROOM FOR THE ELECTRICAL METER & THE GAS WATER HEATER W/COMBUSTIBLE MATERIAL ROOM #35074505P | Oct 31, 2014 WRITTEN OFF | $0 |
| Apr 3, 2014 | Construction CLASS - 1 FAIL TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV #35013780K ISSUED ON 6/15/13 FOR WORK W/O PERMIT @ FLOORS 4&5 APTS DESIGNATED 12&15 ALTERED PLUMBING & ERECTED PARTITIONS TO CREATE SINGLE ROOM OCCUPANCIES #35054908L | Aug 8, 2014 WRITTEN OFF | $0 |
| Feb 25, 2014 | Unknown CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER PROVIDE REQUIRED CORRIDOR WIDTH PER BC 1016.2; 27-369 AT 4TH STORY PUBLIC CORRIDOR WIDTH PARTIALLY OBSTRUCTED BY STORAGE OF A RESD REFRIGERATOR IN FRONT OF APT #35085165L | Apr 18, 2014 IN VIOLATION | $0 |
| Dec 31, 2013 | Construction CLASS - 1 FAILURE TO COMPLY W/THE COMM'S VACATE ORDER #78/2013 AT 5TH STORY APT DESIGNATED 15 OBSERVED 1 OF 5 SRO'S OCCUPIED W/O ACCESS TO FIRE ESCAPE CONTRARY TO VACATE ORDER. REMEDY: COMPLY W/THE COMM'S VACATE ORDER. #35084165R | Mar 7, 2014 WRITTEN OFF | $0 |
| Jul 31, 2013 | Signs CLASS - 1 OAC SIGN PROHIBITED IN C1-4 DISTRICT. (HEALTHFIRST) REMEDY: REMOVE ILLEGAL SIGN. #35027245X | Mar 7, 2014 WRITTEN OFF | $0 |
| Jul 31, 2013 | Signs CLASS - 1 OAC FAILURE TO HAVE LICENSED SIGN HANGER ATTACH OR ERECT SIGN. (HEALTHFIRST) REMEDY: REMOVE ILLEGAL SIGN. #35027247J | Mar 7, 2014 WRITTEN OFF | $0 |
| Jul 31, 2013 | Signs CLASS - 1 OAC SIGN ON DISPLAY W/O A PERMIT. (HEALTHFIRST) REMEDY: REMOVE ILLEGALSIGN. #35027243M | Mar 7, 2014 WRITTEN OFF | $0 |
| Jun 15, 2013 | Construction CLASS - 1 WORK W/O PERMIT.WORK NOTED: INTERIOR SHEETROCK PARTITION WALLS ERECTEDAND PLUMBING AND ELECTRICAL WORK REMOVED AND INSTALLED TO CREATE 5 SINGLE ROOMS AT APT 15 ON 5TH FLR SOUTHWEST REAR AND 3 SINGLE ROOMS IN AP #35013780K | Oct 11, 2013 IN VIOLATION | $0 |
| Jun 15, 2013 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT WHICH IS ALLOWED BY THE BLDG DEPT RECORDS. NOTE:5TH FLR APT #15 CONVERTED INTO 5 SROS AND 4TH FLR APT #12 CONVERTED INTO 3 SROS WITH KEYED ENTRY DOORS,FOR AN ENCLOSED SPACE WITH BED, #35013781M | Oct 11, 2013 WRITTEN OFF | $0 |
| Jun 15, 2013 | Construction CLASS - 1 BC1001.9 FAILURE TO PROVIDE SECONDARY MEANS OF EGRESS WHERE REQURIED. APARTMENT #12 AT 5TH FLR SOUTHWEST AT REAR AND APARTMENT #15 AT 4TH FLSOUTHWEST SIDE WALL HAVE A TOTAL OF 8 SINGLE ROOM OCCUPANCY 5 AT APT15 #35013782Y | Oct 11, 2013 IN VIOLATION | $0 |
| Apr 5, 2013 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLICANCES OR WIRING IN USE: THE ENTIRE BSMT:DEFECTIVE OPEN WIRING ARE IN USE, DEFECTIVE RECEPTACLE OUTLETS ARE IN USE,DEFECTIVE #35009478H | Oct 11, 2013 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #06299 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 INTERNAL HGH PRESSURE INSPECTION #01038 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL HGH PRESSURE INSPECTION #00239 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL HGH PRESSURE INSPECTION #00257 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #05884 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 INTERNAL HGH PRESSURE INSPECTION #01108 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION #01753 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #34618 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #14302 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION #04099 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION #02967 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION #00600 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #35389 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION #00645 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION #01855 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL HGH PRESSURE INSPECTION #03073 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 INTERNAL HGH PRESSURE INSPECTION #04216 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #14418 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE INSPECTION #00353 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | HIGH PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL HIGH PRESSURE INSPECTION #01502 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #08560 | DOB VIOLATION - ACTIVE |
| Mar 16, 2020 | HIGH PRESSURE BOILER VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION #00386 | DOB VIOLATION - ACTIVE |
| Mar 16, 2020 | HIGH PRESSURE BOILER VIOLATION ISSUED - FAILURE TO FILE 2017 EXTERNAL HIGH PRESSURE BOILER INSPECTION #00361 | DOB VIOLATION - ACTIVE |
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #04535 | DOB VIOLATION - ACTIVE |
| Dec 2, 2015 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00123 | DOB VIOLATION - ACTIVE |
| Dec 2, 2015 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00121 | DOB VIOLATION - ACTIVE |
| Dec 3, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00148 | DOB VIOLATION - ACTIVE |
| Dec 3, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00150 | DOB VIOLATION - ACTIVE |
| Dec 3, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00149 | DOB VIOLATION - ACTIVE |
| Sep 4, 2014 | PLUMBING 1 HOTWATER HEATER, 1 SINK, 1 TOILET AND RELATED GAS WASTE, HOT & COLD WATER LINES INSTALLED IN THE CELLAR WITHOUT A PERMIT REMEDY: OBTAIN A PERMIT #PL20601DG | DOB VIOLATION - ACTIVE |
| Sep 11, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00065 | DOB VIOLATION - ACTIVE |
| Sep 11, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00064 | DOB VIOLATION - ACTIVE |
| Sep 11, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00066 | DOB VIOLATION - ACTIVE |
| Jun 13, 2012 | CONSTRUCTION #CER01DF | DOB VIOLATION - ACTIVE |
| Jan 6, 2009 | CONSTRUCTION #0601AK | DOB VIOLATION - ACTIVE |
| Feb 9, 1990 | CONSTRUCTION #6AA1 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL HGH PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 INTERNAL HGH PRESSURE INSPECTION | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 6) | Active |
| Sep 23, 2024 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL HGH PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2023 INTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 INTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler HBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler HBLVIO VIOLATION ISSUED - FAILURE TO FILE 2022 EXTERNAL HIGH PRESSURE BOILER INSPECTION | Active |
| Apr 25, 2023 | Boiler HBLVIO VIOLATION ISSUED - FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE BOILER INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Mar 16, 2020 | Boiler HBLVIO VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION | Active |
| Mar 16, 2020 | Boiler HBLVIO VIOLATION ISSUED - FAILURE TO FILE 2017 EXTERNAL HIGH PRESSURE BOILER INSPECTION | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| Dec 2, 2015 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 2, 2015 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 3, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 3, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 3, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 11, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 11, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 11, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 1, 2025 | B | Apt 11 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 11 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 11 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Nov 5, 2025 |
| Aug 14, 2025 | B | Apt 6 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH SPRING BALANCE AT 1ST WINDOW FROM EAST AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 18, 2025 |
| Aug 14, 2025 | B | Apt 6 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 18, 2025 |
| Aug 14, 2025 | C | Apt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 9, 2025 |
| Aug 14, 2025 | C | Apt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 9, 2025 |
| Aug 14, 2025 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR TOO HIGH AT PUBLIC HALL, 1st STORY | Nov 17, 2025 |
| Aug 14, 2025 | A | §27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS AT PUBLIC HALL AT 1ST STORY | Nov 17, 2025 |
| Aug 14, 2025 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Nov 17, 2025 |
| Aug 14, 2025 | B | Apt 6 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH SPRING BALANCE AT WEST WALL IN THE KITCHEN LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 18, 2025 |
| Aug 14, 2025 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY | Nov 17, 2025 |
| Aug 14, 2025 | B | Apt 6 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER WINDOW SASH AT 2ND WINDOW FROM EAST AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 18, 2025 |
| Aug 14, 2025 | B | Apt 6 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR. IN THE 1st ROOM FROM EAST LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 18, 2025 |
| Jun 16, 2025 | B | Apt 11 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (LESS THAN 10.SQ.FEET) IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17699447 ISSUED 12-FEB-25 HAS BEEN UPGRADED TO CLASS B PER ADMIN | Jul 21, 2025 |
| Jun 16, 2025 | B | Apt 11 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (LESS THAN 10 SQ.FT.) IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17699437 ISSUED 12-FEB-25 HAS BEEN UPGRADED TO CLASS B PER ADMINI | Jul 21, 2025 |
| Feb 14, 2025 | B | Apt 11 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK THRU THE CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 21, 2025 |
| Feb 14, 2025 | C | Apt 11 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 20, 2025 |
| Feb 14, 2025 | B | Apt 11 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR (MISSING) LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 21, 2025 |
| Feb 14, 2025 | B | Apt 11 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). (MISSING) LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 21, 2025 |
| Feb 14, 2025 | B | Apt 11 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 21, 2025 |
| Feb 14, 2025 | B | Apt 11 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK THRU THE CEILING IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 21, 2025 |
| Feb 14, 2025 | C | Apt 11 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 12, 2025 |
| Feb 14, 2025 | C | Apt 11 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 11, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 12, 2025 |
| Dec 30, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Jan 5, 2025 |
| Dec 27, 2024 | C | Apt 7 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7, 3rd STORY | Jan 2, 2025 |
| Dec 19, 2024 | B | Apt 7 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE KITCHEN LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 23, 2025 |
| Dec 19, 2024 | B | Apt 7 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 23, 2025 |
| Dec 19, 2024 | B | Apt 7 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 23, 2025 |
| Dec 19, 2024 | B | Apt 7 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 23, 2025 |
| Dec 19, 2024 | B | Apt 7 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE PRIVATE HALLWAY LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 23, 2025 |
| Dec 19, 2024 | C | Apt 7 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 14, 2025 |
| Dec 19, 2024 | C | Apt 7 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT KITCHEN SINK IN THE KITCHEN LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Dec 25, 2024 |
| Dec 19, 2024 | B | Apt 7 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 23, 2025 |
| Nov 27, 2024 | C | Apt 12A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 23, 2024 |
| Nov 27, 2024 | B | Apt 12A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 1, 2025 |
| Nov 27, 2024 | A | Apt 12A · § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL , IN THE BATHROOM LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 2, 2025 |
| Nov 27, 2024 | B | Apt 12A · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET , IN THE BATHROOM LOCATED AT APT 12A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 1, 2025 |
| Nov 25, 2024 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING , 1st STORY | Dec 1, 2024 |
| Nov 25, 2024 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Feb 28, 2025 |
| Nov 25, 2024 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED, 1st STORY | Feb 28, 2025 |
| Nov 25, 2024 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER., 1st STORY | Feb 28, 2025 |
| Aug 5, 2024 | C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE BROKEN METAL TREAD 5TH FROM BOTTOM UP AT 4TH STORY BALCONY AT FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL (SOUTH YARD) AT FIRE ESCAPE | Aug 11, 2024 |
| Aug 5, 2024 | C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE BROKEN METAL TREAD 3RD FROM BOTTOM UP AT 5TH STORY BALCONY AT FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL (SOUTH YARD) AT FIRE ESCAPE | Aug 11, 2024 |
| Aug 5, 2024 | C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE BROKEN METAL TREAD 13TH FROM BOTTOM UP AT 2ND STORY BALCONY AT FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL (SOUTH YARD) AT FIRE ESCAPE | Aug 11, 2024 |
| Apr 3, 2024 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Apr 17, 2024 |
| Mar 7, 2024 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Jun 10, 2024 |
| Mar 7, 2024 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY | Jun 10, 2024 |
| Mar 7, 2024 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY | Mar 13, 2024 |
| Mar 7, 2024 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Jun 10, 2024 |
| Mar 7, 2024 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY | Jun 10, 2024 |
| Oct 16, 2023 | C | Apt 11 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOOSE VINYL TILES AT FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 11, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 22, 2023 |
| Oct 16, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AT VESTIBULE TO 1ST STORY AT PUBLIC HALL | Oct 30, 2023 |
| Oct 16, 2023 | C | Apt 11 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CRACKED VINYL TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 11, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 22, 2023 |
| Oct 16, 2023 | B | Apt 11 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SAGGING WOOD UNDER FLOOR IN THE FOYER LOCATED AT APT 11, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 20, 2023 |
| Oct 16, 2023 | B | Apt 11 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WARPPED WOOD UNDER FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 11, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 20, 2023 |
| Oct 16, 2023 | C | Apt 11 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MISSING VINYL TILES AT FLOOR IN THE FOYER LOCATED AT APT 11, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 22, 2023 |
| Oct 16, 2023 | B | Apt 11 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 20, 2023 |
| Oct 16, 2023 | B | Apt 11 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 20, 2023 |
| Oct 16, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AT STREET TO VESTIBULE AT 1ST STORY AT PUBLIC HALL | Oct 30, 2023 |