Brooklyn · Block 1765 · Lot 15 · 11205

195 Sandford Street

5 floors · 123,895 sq ft · built 1925 · class W1 · owner of record: Nyc Department Of Education

12open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
167dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 123,895 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 167 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 167 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 777 days
Next cycle year 2028
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1765). Agency page

Dec 31, 2035
in 3333 days
Next due 2035
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-14 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4)
IssuedViolationHearingBalance
May 18, 2026Construction CLASS - 2
REISSUE: 35717574P-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FLASHING AT ROOF LEVEL IS LOOSE. REMEDY: COMPLY WITH CODE.
#35732946M
Jun 26, 2026
POP/IN-VIO
$0
May 1, 2025Construction CLASS - 2
REISSUE: #35677409H DATE OF ISSUE: 04-16-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AND OBSERVED AT THE THE TIME OF INSPECTION AT ROOF LEVEL ADJACENT TO BULKHEAD A AND B THERE IS METAL F
#35717574P
May 27, 2025
POP/IN-VIO
$0
Apr 16, 2024Construction CLASS - 2
REISSUE#35672881Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT TIME OF INSPECTION OF MY INSPECTION I OBSERVE AT THE ROOF LEVEL ADJACENT TO BULKHEAD A AND B.THE METAL FLASHING IS LOOSE.ALSO AT THE UP
#35677409H
May 13, 2024
POP/IN-VIO
$0
Mar 6, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT ROOF LEVEL ADJACENT TO BULKHEAD A & B THERE IS METAL FLASHING THAT IS LOOSE.ALSO AT UPPER ROOF BY BULKHEAD C,METAL VENTS HAVE LARGE HOLES ON SIDES
#35672881Z
Jun 14, 2023
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (8)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 9:53 AM ET. BBL 3017650015.

Look up another building