Staten Island · Block 18 · Lot 15 · 10301

195 Daniel Low Terrace

4 floors · 348,000 sq ft · built 1965 · class W1 · owner of record: Nyc Department Of Education

13open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
168dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 348,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 18). Agency page

Dec 31, 2028
in 778 days
Next due 2028
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-23 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7)
IssuedViolationHearingBalance
Jan 29, 2026Construction CLASS - 2
RE-ISSUE #35692175J. FAILURE TO MAINTAIN BULDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS AS PER BC 1006.1; 27-381. NOTED: THERE WERE SEVERAL EMERGENCY LIGHTS THAT
#35724906H
Mar 9, 2026
POP/IN-VIO
$0
Jan 29, 2026Construction CLASS - 2
RE-ISSUE #35692476L. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNERS. NOTED: OBSERVED AT T. O. I. THERE IS A DOOR ON THE 4TH FLOOR(CROSS CORRIDOR) NOT CLOSING PROPERLY. THIS SMOKE DOOR NEEDS TO BE REPAIR
#35724905X
Mar 9, 2026
POP/IN-VIO
$0
Jan 29, 2026Construction CLASS - 2
RE-ISSUE #35692177N. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: IN THE CORRIDORS ON 2ND FLOOR ADJACENT TO EXIT #9 THERE IS IS CRACKED GLASS PANEL THAT'S LOCATED ABOVE PLAY AREA. REMEDY: REPAI
#35724904Y
Mar 9, 2026
POP/IN-VIO
$0
Feb 18, 2025Construction CLASS - 2
RE-ISSUE #35678827P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PERBC 1006.1; 27-381. NOTED: AT T. O. I. THERE WERE SEVERAL EMERGENCY LIG
#35692175J
Apr 30, 2025
POP/IN-VIO
$0
Feb 18, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT T. O.I. OBSERVED, ON 2ND FLOOR, ADJACENT TO EXIT #9, THERE IS CRACKED GLASSIN ONE OF THE CORRIDOR WINDOWS. REMEDY: REPAIR/REPLACE GLASS.
#35692177N
Apr 30, 2025
POP/IN-VIO
$0
Feb 18, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT T. O.I. OBSERVED ON THE 4TH FLOOR. ONE OF THE CROSS CORRIDOR(SMOKE DOOR) DOORS WAS NOT CLOSING PROPERLY. REMEDY: REPAIR/REPLACE.
#35692176L
Apr 30, 2025
POP/IN-VIO
$0
Jun 25, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:AT T.O.I. SEVERAL EMERGENCY LIGHTS THROUGHOUT THE SCHOOL WERE NOT OPER
#35678827P
Sep 4, 2024
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (6)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 2:03 PM ET. BBL 5000180015.