Brooklyn · Block 2575 · Lot 9 · 11222

194 Greenpoint Avenue

3 floors · 2 apartments · 3,378 sq ft · built 2025 · class S2 · owner of record: 323 Eckford St Llc

17open violations
$77,475ECB/OATH penalties owed
0HPD class C (immediately hazardous)
795dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 308 days
Required only if the owner doesn't live there
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 795 days
Next cycle year 2028

Open violations

ECB / OATH (23) · $77,475 owed
IssuedViolationHearingBalance
Jun 15, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED PEDESTRIAN PROTECTION (JERSEY BARRIERS) INSTALLED AT EXPOS 1&4 CONTRARY TO CODE 3307.2. PROVIDED JERSEY BARRIERS WERE NOT FILLED WITH WATER OR SAND AND NOT SECURED TOGETHER TO PREVENT
#39555500Z
Sep 21, 2026
DEFAULT
$2,430
Jun 15, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 AND 4 WITH NO "NO SMOKING" SIGNS PROVIDED ON FENCE EXTERIOR OR FENCE INTERIOR CONTRARY TO CODE 3303.7.3 SMOKING. SMOKING SHALL BE PROHIBITED AT ALL CONSTR
#39555494L
Sep 21, 2026
DEFAULT
$1,280
Jun 15, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1&4 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. MULTIPLE PROTRUDING OBJECTS (NAILS, SCREWS, WOOD) AT ALL EXPOS. 8FT HEIGHT REQUIREMENT NOT MET ABOVE EN
#39555490Y
Sep 21, 2026
DEFAULT
$1,030
Jun 15, 2026Unknown CLASS - 1
UPON INSPECTION I OBSERVED A FENCE INTRUDING ON THE SIDEWALK AND A INADEQUATE/ HAZARDOUS PATHWAY PROVIDED IN STREET. WALKWAY WAS LESS THAN 5FT CONTRARY TO CODE 3307.2.6. PEDESTRIANS ARE FORCED TO SQUEEZE THROU
#39555495N
Sep 21, 2026
DEFAULT
$5,030
Jun 15, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1&4 WITH NO FENCE PROJECT INFO PANELS PROVIDED AT EXPOS 1&4 CONTRARY TO CODES 3301.9.1 FENCE PROJECT INFORMATION PANEL & 3301.9.1.2 POSTING OF PROJECT INFOR
#39555491X
Sep 21, 2026
DEFAULT
$1,280
May 21, 2026Construction CLASS - 2
OBSERVED INADEQUATE CONSTRUCTION FENCE @ PERIMETER OF JOBSITE. CONSTRUCTION HAS ADVERTISEMENTS PLASTERED ALONG THE PERIMETER, CONSTRUCTION FENCE WOOD PANEL CHIPPED ON TOP, AND DISLODGED WITH GAPS BETWEEN PANELS
#39554435R
Sep 9, 2026
DEFAULT
$1,030
Apr 9, 2026Unknown CLASS - 2
B.C 3307.4 OBSERVED A CONSTRUCTION FENCE INSTALLED FULLY BLOCKING OFF THE SIDEWALK WHICH FORCES PEDESTRIANS TO HAVE TO USE THE TEMPORARY WALKWAY WHICH WAS SETUP WITH JERSEY BARRIERS ON THE STREET. DOT PERMITS S
#39552816L
Feb 9, 2027
PENDING
$2,500
Apr 9, 2026Construction CLASS - 2
OBSERVED JERSEY BARRIERS ON THE STREET INSTALLED AS A PEDESTRIAN WALKWAY DUE TO THE CONSTRUCTION FENCE FULLY BLOCKING OFF THE SIDEWALK. BARRIERS ARE NOT MAINTAINED AS PER SPECIFICATIONS. MISSING INTERLOCKING CO
#39552817N
Feb 9, 2027
PENDING
$1,250
Feb 1, 2026Unknown CLASS - 2
OBSERVED PROPOSED 3STORY NB WITH PUMP-JACK SCAFFOLDS INSTALLED W/OUT ACTIVE PERMIT. PUMP-JACK SCAFFOLDS ARE INSTALLED @EXPOS1&4 AND SURPASSING THE HEIGHT OF THE BUILDING, POSTS OF PUMPJACK HIGHER THAN 40FT. UPO
#39549798J
Nov 6, 2026
PENDING
$1,250
Feb 1, 2026Unknown CLASS - 2
OBSERVED CLOSED 3STORY NB. PEDESTRIAN WALKWAYS BEING USED @EXPOS1&4 NOT UP TO CODE. PEDESTRIAN WALKWAY IS NOT MINIMUM OF 5FT AS REQUIRED BY DOT STIPULATIONS, UNCLEARED SNOW IS HAZARDOUS,YODOCKS NOT CONNECTED TO
#39549797H
Nov 6, 2026
PENDING
$625
Feb 1, 2026Unknown CLASS - 2
JOBSITE FENCE NOT MAINTAINED AS PER 3307.7. FENCE @EXPO1 DISLODGING ONTO PEDESTRIAN WALKWAY,AT RISK OF FALLING ON PUBLIC.PUT PUBLIC AT RISK OF TRIPPING,FALLING,RUNNING INTO FENCE. @EXPO1&4 EXCESSIVE ADS POSTED
#39549796X
Nov 6, 2026
PENDING
$2,500
Feb 1, 2026Construction CLASS - 1
OBS MAKESHIFT GUARDRAILS @ CORNER OF EXPO1&2 ON FLOORS 2&3 ARE DISLODGED, NO DEBRIS NETTING, NOT AS PER 3308.7.3. CONDITIONS UNSAFE TO PUBLIC, PROPERTY, AND WORKERS. DOB ISSUED WINTER WEATHER ADVISOR;: EXPECTED
#39549795Y
Nov 6, 2026
$5,000
Dec 8, 2025Construction CLASS - 2
OBSERVED ACTIVE SITE UPON REQUEST FAILED TO PROVIDE SITE SAFETY PLANS, NO STRUCTURAL DESIGN DRAWINGS, NO MANUFACTURER SPECIFICATIONS FOR COLD FORM STEEL/ C-JOIST WORK @ LEVEL 1. ALL APPROVE DOCUMENTS MUST BE MA
#39547730Y
Oct 8, 2026
DEFAULT
$1,280
Dec 8, 2025Unknown CLASS - 2
OBSERVED ACTIVE SITE WITH MUTIPLE UNSAFE CONDITIONS 3301.5 WORKERS ON SECOND LEVEL FULLY TIE-OFF WITHOUT ANY PROPER INGRESS/ EGRESS, NO THREE POINTS OF CONTRACT WITH FULLY EXTENDED CONSTRUCTION LATTER. ACTIVE W
#39547732H
Oct 8, 2026
DEFAULT
$2,530
Dec 6, 2025Construction CLASS - 2
AT THE TIME OF INSPECTION, INACTIVE JOBSITE. I OBSERVED THAT THE CONSTRUCTION FENCE PANELS AT EXPOSURE ALL EXPOSURE NOT PROPERLY MAINTAINED PURSUANT TO SUBSECTION ACCORDING TO BC 3307.7. FENCE PANELS IN INADEQ
#39547686X
Oct 5, 2026
DEFAULT
$1,030
Dec 6, 2025Construction CLASS - 2
OBSERVED JERSEY BARRIERS IN USE OF A PEDESTRIAN WALK WAY WITH A SPACE OF 2 FT 5" . MOST AREAS AROUND THE SITE ONLY HAD A 4 FOOT CLEARANCE. PEOPLE HAD TO TAKE TURNS PASSING. THIS CREATES A SAFETY HAZARD FOR PEDE
#39547691K
Oct 5, 2026
DEFAULT
$2,430
Nov 18, 2025Unknown CLASS - 2
CONSTRUCTION SUPERINTENDENT FAILED TO ENSURE THAT COMPETENT PERSON ON DAILY LOG BOOK FOR 11-18-2025 HAD VALID SST CARD, JOBSITE @ SOE/ EXCAVATION PHASE W/OUT PLANS, SOE, DAMAGES TO ADJACENT PROPERTIES, AND PEDE
#39547106K
Nov 6, 2026
PENDING
$5,000
Nov 18, 2025Unknown CLASS - 1
IVAN BOSTON STATED TO BE THE DESIGNATED COMPETENT PERSON, UPON VERIFICATION SST CARD, CARD WITH MULTIPLE EXPIRED REQUIRED/ MANDATORY CLASSES. CONSTRUCTION SUPERINTENDENT NOT PRESENT, ALTERNATE CS NOR ALTERNATE
#39547105Z
Nov 6, 2026
PENDING
$5,000
Nov 18, 2025Construction CLASS - 1
OBSERVED STREET OPERATIONS AFFECTING PEDESTRIANS & VEHICULAR TRAFFIC IN THE STREET, WITHOUT FLAG PERSONS TO CONTROL TRAFFIC & PEDESTRIANS WHILE WORK BEING PERFORMED BETWEEN STREET & SIDEWALK, YODOK SYSTEM TO MA
#39547102N
Nov 6, 2026
$10,000
Nov 18, 2025Unknown CLASS - 1
OBSERVED HEAVY MACHINE EXCAVATOR BEING OPERATED/ ROTATING OF EXCAVATED SOIL, ABOVE WORKERS, EXCAVATOR ON A SHEER/ REMOVED SOIL AT BASE. NO PE DESIGN DRAWINGS FOR STABILITY & PLACEMENT/ OPERATING OF EQUIPMENT OF
#39547103P
Nov 6, 2026
$5,000
Nov 18, 2025Construction CLASS - 1
ACTIVE JOBSITE @ EXCAVATION/ FOUNDATION PHASE UPON REQUEST FOR EXCAVATION PLANS, SITE SAFETY PLAN, PE DESIGN DRAWINGS FOR STAYFORM & INSPECTIONS, PRE-CONSTRUCTION SURVEY BY REGISTERED PROFESSIONAL, NONE WERE AV
#39547101L
Nov 6, 2026
$5,000
Nov 18, 2025Construction CLASS - 1
OBSERVED GC POURING CONCRETE AT 3:45 PM WHILE ON NOTICE OF A STOP WORK ORDER FOR STOP ALL EXCAVATION & FOUNDATION WORK UNDER COMPLAINT #3A38146. GC OPERATED ON HIS OWN, FAILED TO MAINTAIN STREET OPERATIONS & E
#39547116Y
Nov 6, 2026
$10,000
Nov 18, 2025Unknown CLASS - 1
OBSERVED LACK OF EGRESS THROUGHOUT THE ENTIRE AT EXCAVATION PHASE, WORKERS USING A SPLIT EXTENSION LADDER NOT REACHING A SAFE PATH/ MEANS OF EGRESS. FAIL TO MAINTAIN EGRESS CREATES A DETRIMENTAL & HAZARDOUS WOR
#39547104R
Nov 6, 2026
$5,000
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Jul 23, 2026DOB SafetyAEUHAZ: Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 10:32 PM ET. BBL 3025750009.

Look up another building