3 floors · 2 apartments · 3,378 sq ft · built 2025 · class S2 · owner of record: 323 Eckford St Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 308 days | Required only if the owner doesn't live there |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 795 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 15, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED PEDESTRIAN PROTECTION (JERSEY BARRIERS) INSTALLED AT EXPOS 1&4 CONTRARY TO CODE 3307.2. PROVIDED JERSEY BARRIERS WERE NOT FILLED WITH WATER OR SAND AND NOT SECURED TOGETHER TO PREVENT #39555500Z | Sep 21, 2026 DEFAULT | $2,430 |
| Jun 15, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 AND 4 WITH NO "NO SMOKING" SIGNS PROVIDED ON FENCE EXTERIOR OR FENCE INTERIOR CONTRARY TO CODE 3303.7.3 SMOKING. SMOKING SHALL BE PROHIBITED AT ALL CONSTR #39555494L | Sep 21, 2026 DEFAULT | $1,280 |
| Jun 15, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1&4 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. MULTIPLE PROTRUDING OBJECTS (NAILS, SCREWS, WOOD) AT ALL EXPOS. 8FT HEIGHT REQUIREMENT NOT MET ABOVE EN #39555490Y | Sep 21, 2026 DEFAULT | $1,030 |
| Jun 15, 2026 | Unknown CLASS - 1 UPON INSPECTION I OBSERVED A FENCE INTRUDING ON THE SIDEWALK AND A INADEQUATE/ HAZARDOUS PATHWAY PROVIDED IN STREET. WALKWAY WAS LESS THAN 5FT CONTRARY TO CODE 3307.2.6. PEDESTRIANS ARE FORCED TO SQUEEZE THROU #39555495N | Sep 21, 2026 DEFAULT | $5,030 |
| Jun 15, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1&4 WITH NO FENCE PROJECT INFO PANELS PROVIDED AT EXPOS 1&4 CONTRARY TO CODES 3301.9.1 FENCE PROJECT INFORMATION PANEL & 3301.9.1.2 POSTING OF PROJECT INFOR #39555491X | Sep 21, 2026 DEFAULT | $1,280 |
| May 21, 2026 | Construction CLASS - 2 OBSERVED INADEQUATE CONSTRUCTION FENCE @ PERIMETER OF JOBSITE. CONSTRUCTION HAS ADVERTISEMENTS PLASTERED ALONG THE PERIMETER, CONSTRUCTION FENCE WOOD PANEL CHIPPED ON TOP, AND DISLODGED WITH GAPS BETWEEN PANELS #39554435R | Sep 9, 2026 DEFAULT | $1,030 |
| Apr 9, 2026 | Unknown CLASS - 2 B.C 3307.4 OBSERVED A CONSTRUCTION FENCE INSTALLED FULLY BLOCKING OFF THE SIDEWALK WHICH FORCES PEDESTRIANS TO HAVE TO USE THE TEMPORARY WALKWAY WHICH WAS SETUP WITH JERSEY BARRIERS ON THE STREET. DOT PERMITS S #39552816L | Feb 9, 2027 PENDING | $2,500 |
| Apr 9, 2026 | Construction CLASS - 2 OBSERVED JERSEY BARRIERS ON THE STREET INSTALLED AS A PEDESTRIAN WALKWAY DUE TO THE CONSTRUCTION FENCE FULLY BLOCKING OFF THE SIDEWALK. BARRIERS ARE NOT MAINTAINED AS PER SPECIFICATIONS. MISSING INTERLOCKING CO #39552817N | Feb 9, 2027 PENDING | $1,250 |
| Feb 1, 2026 | Unknown CLASS - 2 OBSERVED PROPOSED 3STORY NB WITH PUMP-JACK SCAFFOLDS INSTALLED W/OUT ACTIVE PERMIT. PUMP-JACK SCAFFOLDS ARE INSTALLED @EXPOS1&4 AND SURPASSING THE HEIGHT OF THE BUILDING, POSTS OF PUMPJACK HIGHER THAN 40FT. UPO #39549798J | Nov 6, 2026 PENDING | $1,250 |
| Feb 1, 2026 | Unknown CLASS - 2 OBSERVED CLOSED 3STORY NB. PEDESTRIAN WALKWAYS BEING USED @EXPOS1&4 NOT UP TO CODE. PEDESTRIAN WALKWAY IS NOT MINIMUM OF 5FT AS REQUIRED BY DOT STIPULATIONS, UNCLEARED SNOW IS HAZARDOUS,YODOCKS NOT CONNECTED TO #39549797H | Nov 6, 2026 PENDING | $625 |
| Feb 1, 2026 | Unknown CLASS - 2 JOBSITE FENCE NOT MAINTAINED AS PER 3307.7. FENCE @EXPO1 DISLODGING ONTO PEDESTRIAN WALKWAY,AT RISK OF FALLING ON PUBLIC.PUT PUBLIC AT RISK OF TRIPPING,FALLING,RUNNING INTO FENCE. @EXPO1&4 EXCESSIVE ADS POSTED #39549796X | Nov 6, 2026 PENDING | $2,500 |
| Feb 1, 2026 | Construction CLASS - 1 OBS MAKESHIFT GUARDRAILS @ CORNER OF EXPO1&2 ON FLOORS 2&3 ARE DISLODGED, NO DEBRIS NETTING, NOT AS PER 3308.7.3. CONDITIONS UNSAFE TO PUBLIC, PROPERTY, AND WORKERS. DOB ISSUED WINTER WEATHER ADVISOR;: EXPECTED #39549795Y | Nov 6, 2026 | $5,000 |
| Dec 8, 2025 | Construction CLASS - 2 OBSERVED ACTIVE SITE UPON REQUEST FAILED TO PROVIDE SITE SAFETY PLANS, NO STRUCTURAL DESIGN DRAWINGS, NO MANUFACTURER SPECIFICATIONS FOR COLD FORM STEEL/ C-JOIST WORK @ LEVEL 1. ALL APPROVE DOCUMENTS MUST BE MA #39547730Y | Oct 8, 2026 DEFAULT | $1,280 |
| Dec 8, 2025 | Unknown CLASS - 2 OBSERVED ACTIVE SITE WITH MUTIPLE UNSAFE CONDITIONS 3301.5 WORKERS ON SECOND LEVEL FULLY TIE-OFF WITHOUT ANY PROPER INGRESS/ EGRESS, NO THREE POINTS OF CONTRACT WITH FULLY EXTENDED CONSTRUCTION LATTER. ACTIVE W #39547732H | Oct 8, 2026 DEFAULT | $2,530 |
| Dec 6, 2025 | Construction CLASS - 2 AT THE TIME OF INSPECTION, INACTIVE JOBSITE. I OBSERVED THAT THE CONSTRUCTION FENCE PANELS AT EXPOSURE ALL EXPOSURE NOT PROPERLY MAINTAINED PURSUANT TO SUBSECTION ACCORDING TO BC 3307.7. FENCE PANELS IN INADEQ #39547686X | Oct 5, 2026 DEFAULT | $1,030 |
| Dec 6, 2025 | Construction CLASS - 2 OBSERVED JERSEY BARRIERS IN USE OF A PEDESTRIAN WALK WAY WITH A SPACE OF 2 FT 5" . MOST AREAS AROUND THE SITE ONLY HAD A 4 FOOT CLEARANCE. PEOPLE HAD TO TAKE TURNS PASSING. THIS CREATES A SAFETY HAZARD FOR PEDE #39547691K | Oct 5, 2026 DEFAULT | $2,430 |
| Nov 18, 2025 | Unknown CLASS - 2 CONSTRUCTION SUPERINTENDENT FAILED TO ENSURE THAT COMPETENT PERSON ON DAILY LOG BOOK FOR 11-18-2025 HAD VALID SST CARD, JOBSITE @ SOE/ EXCAVATION PHASE W/OUT PLANS, SOE, DAMAGES TO ADJACENT PROPERTIES, AND PEDE #39547106K | Nov 6, 2026 PENDING | $5,000 |
| Nov 18, 2025 | Unknown CLASS - 1 IVAN BOSTON STATED TO BE THE DESIGNATED COMPETENT PERSON, UPON VERIFICATION SST CARD, CARD WITH MULTIPLE EXPIRED REQUIRED/ MANDATORY CLASSES. CONSTRUCTION SUPERINTENDENT NOT PRESENT, ALTERNATE CS NOR ALTERNATE #39547105Z | Nov 6, 2026 PENDING | $5,000 |
| Nov 18, 2025 | Construction CLASS - 1 OBSERVED STREET OPERATIONS AFFECTING PEDESTRIANS & VEHICULAR TRAFFIC IN THE STREET, WITHOUT FLAG PERSONS TO CONTROL TRAFFIC & PEDESTRIANS WHILE WORK BEING PERFORMED BETWEEN STREET & SIDEWALK, YODOK SYSTEM TO MA #39547102N | Nov 6, 2026 | $10,000 |
| Nov 18, 2025 | Unknown CLASS - 1 OBSERVED HEAVY MACHINE EXCAVATOR BEING OPERATED/ ROTATING OF EXCAVATED SOIL, ABOVE WORKERS, EXCAVATOR ON A SHEER/ REMOVED SOIL AT BASE. NO PE DESIGN DRAWINGS FOR STABILITY & PLACEMENT/ OPERATING OF EQUIPMENT OF #39547103P | Nov 6, 2026 | $5,000 |
| Nov 18, 2025 | Construction CLASS - 1 ACTIVE JOBSITE @ EXCAVATION/ FOUNDATION PHASE UPON REQUEST FOR EXCAVATION PLANS, SITE SAFETY PLAN, PE DESIGN DRAWINGS FOR STAYFORM & INSPECTIONS, PRE-CONSTRUCTION SURVEY BY REGISTERED PROFESSIONAL, NONE WERE AV #39547101L | Nov 6, 2026 | $5,000 |
| Nov 18, 2025 | Construction CLASS - 1 OBSERVED GC POURING CONCRETE AT 3:45 PM WHILE ON NOTICE OF A STOP WORK ORDER FOR STOP ALL EXCAVATION & FOUNDATION WORK UNDER COMPLAINT #3A38146. GC OPERATED ON HIS OWN, FAILED TO MAINTAIN STREET OPERATIONS & E #39547116Y | Nov 6, 2026 | $10,000 |
| Nov 18, 2025 | Unknown CLASS - 1 OBSERVED LACK OF EGRESS THROUGHOUT THE ENTIRE AT EXCAVATION PHASE, WORKERS USING A SPLIT EXTENSION LADDER NOT REACHING A SAFE PATH/ MEANS OF EGRESS. FAIL TO MAINTAIN EGRESS CREATES A DETRIMENTAL & HAZARDOUS WOR #39547104R | Nov 6, 2026 | $5,000 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 23, 2026 | DOB Safety | AEUHAZ: | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 10:32 PM ET. BBL 3025750009.